Operation
Owner’s Manual for MLT6SMDS - MLT6SKDS Light Tower
33
NOTE:
Disconnect the battery if the unit will be stored for
an extended period. Refer to the engine operator’s
manual for additional extended storage procedures.
Automatic Shutdown
This unit is equipped with a low oil pressure and high
coolant temperature automatic shutdown system. This
system automatically shuts off the fuel supply to stop the
engine if oil pressure drops too low, or the engine
exceeds normal operating temperature. Return the main
circuit breaker to STOP to reset the unit after the cause
of shutdown has been determined.
Lowering the Mast—Manual
Winch
1.
Shut down the lights and engine. See
.
2.
Lower the mast.
3.
Use the winch handles to collapse the mast to its
lowest position. Verify the electrical cord does not
get caught in, or pinched by, the mast while it is
being lowered.
.
IMPORTANT NOTE: Contact a GMP ASD immedi-
ately if the mast hangs up or the winch cable devel-
ops slack.
4.
See
. If the unit is going to be moved,
rotate the mast so the lights face the rear of the unit.
Figure 3-15. Stowed (Travel) Position
To rotate the mast:
a. Loosen the mast rotation knob.
b. Rotate the mast until the white arrows are
aligned and the metal stop tabs are touching.
c. Tighten the mast rotation knob.
Lowering the Mast—Electric
Winch (If Equipped)
NOTE:
On key switch models, key must be in RUN to
operate electric winch.
1.
Press and hold the upper winch control switch
downward to collapse the mast to its lowest
position. Verify the electrical cord does not get
caught in, or pinched by, the mast while it is being
lowered.
2.
Shut down the engine. See
3.
If the unit is going to be moved, rotate the mast so
the lights face the rear of the unit. To rotate the
mast:
a. Loosen the mast rotation knob.
b. Rotate the mast until the white arrows are
aligned and the metal stop tabs are touching.
c. Tighten the mast rotation knob.
NOTE:
The electric winch models are equipped with a
safety limit switch. This switch disconnects power to the
winch after the mast is completely raised or lowered. This
prevents the cable from continuing to unwind and becom-
ing entangled around the winch drum.
IMPORTANT NOTE: Contact a GMP ASD immedi-
ately if the mast hangs up or the winch cable devel-
ops slack.
NOTE:
If the light tower is not operational, and the
batteries do not have enough power to lower the mast, it
may be necessary to lower the mast manually. Always
attempt to recharge the batteries and lower the mast
electrically before proceeding.
WARNING
Personal Injury. Stop immediately if the mast hangs
up or the winch cable develops slack. Excess slack
could cause the mast to collapse, resulting in personal
injury or equipment damage.
(000265)
008646
WARNING
Personal Injury. Stop immediately if the mast hangs
up or the winch cable develops slack. Excess slack
could cause the mast to collapse, resulting in personal
injury or equipment damage.
(000265)
Содержание MAGNUM MLT6SKDS
Страница 46: ...Maintenance 42 Owner s Manual for MLT6SMDS MLT6SKDS Light Tower This page intentionally left blank...
Страница 52: ...Wiring Diagrams 48 Owner s Manual for MLT6SMDS MLT6SKDS Light Tower AC Wiring Diagram MLT6SKDS With Power Zone...
Страница 65: ...Service Log Owner s Manual for MLT6SMDS MLT6SKDS Light Tower 61 This page intentionally left blank...
Страница 66: ...Service Log 62 Owner s Manual for MLT6SMDS MLT6SKDS Light Tower This page intentionally left blank...
Страница 67: ......