Operation
32
Owner’s Manual for MLT6SMDS - MLT6SKDS Light Tower
Dusk to Dawn Sensor (Power
Zone–DLA) (If Equipped)
See
. If equipped with the Power Zone-DLA
controller, this unit includes a “dusk to dawn”
nightwatchman sensor (A) to detect the surrounding light
level, automatically starting the engine and turning the
lights on at dusk. The engine will run and the lights will
remain illuminated until dawn.
To prepare the sensor for use, perform the following
procedure at the time of day you want the lights to turn
on:
1.
Verify the Power Zone–DLA is set up and the unit
is on.
2.
Slide the light shield bracket up, decreasing the
sensor’s exposure to light, until the lights turn on.
3.
Tighten screws on shield.
Figure 3-13. Dusk to Dawn Sensor
Customer Convenience
Receptacles
See
. The unit is equipped with convenience
receptacles for powering accessories or tools from the
generator. Power is supplied to the receptacles any time
the engine is running and the main circuit breaker is
switched to the ON (I) position. Each receptacle has an
individual circuit breaker, located on the control box.
Refer to
Figure 3-14. Convenience Receptacles
The circuit breakers are labeled with the corresponding
voltage for the receptacle they protect. The standard
receptacle panel is equipped with the following recepta-
cles:
•
One 240V/30A Twist-lock (A)
•
One120V/20A GFCI (B)
NOTE:
Do not draw more than a combined total of
4,800W from the receptacles with the lights on. This will
overload the generator and cause the main circuit
breaker to trip. If the breaker trips, switch off the lights,
remove some of the loads connected to the receptacles.
With the lights off, the full generator output may be used
with the 240V twist-lock receptacle.
Shutting Down the Unit
Verify with personnel using power supplied by the unit
and notify them power will be turned off. Verify the power
shutdown will not create any hazards by accidentally
turning off equipment that needs to remain running
(pumps, compressors, lights, etc.).
1.
Remove all loads from the receptacles.
2.
Switch the light circuit breaker to OFF (O).
3.
Switch the main circuit breaker OFF (O).
4.
Move the control power switch to STOP.
Shutting Down the Unit (Power
Zone–DLA) (If Equipped)
Verify with personnel using power supplied by the unit
and notify them power will be turned off. Verify the power
shutdown will not create any hazards by accidentally
turning off equipment that needs to remain running
(pumps, compressors, lights, etc.).
1.
Remove all loads from the receptacles.
2.
Turn the lights off using the controller.
3.
Switch the main circuit breaker OFF (O).
4.
Press the Stop (O) button.
5.
After the unit shuts down, switch the control power
switch OFF (O).
A
002528
008646
A
B
002535
Содержание MAGNUM MLT6SKDS
Страница 46: ...Maintenance 42 Owner s Manual for MLT6SMDS MLT6SKDS Light Tower This page intentionally left blank...
Страница 52: ...Wiring Diagrams 48 Owner s Manual for MLT6SMDS MLT6SKDS Light Tower AC Wiring Diagram MLT6SKDS With Power Zone...
Страница 65: ...Service Log Owner s Manual for MLT6SMDS MLT6SKDS Light Tower 61 This page intentionally left blank...
Страница 66: ...Service Log 62 Owner s Manual for MLT6SMDS MLT6SKDS Light Tower This page intentionally left blank...
Страница 67: ......