background image

Owner’s Manual for DF 2.2 Dust Suppression System

7

Operation

Section 3: Operation

Operation and Use Questions

Contact  your  nearest  Generac  Mobile  Products Authorized
Service Dealer (ASD), or contact

 

Generac Mobile Products

Technical Service at 1-800-926-9768 or

www.generacmobileproducts.com

  with  any  questions  or

concerns about unit operation and maintenance.

Before Starting

1. Place unit on flat ground in a well ventilated area.
2. Place  barriers  6  ft  (2  m)  around  unit  to  prevent

unauthorized personnel from nearing unit.

3. Verify sufficient water supply is properly connected

See 

Water System Connection

.

4. Inspect  all  electrical  cords;  repair  or  replace  any

cords that are cut, worn, or bare.

5. Verify  power  cord  is  properly  connected  to  a  240

volt  60  hz  power  source.  See 

Electrical

Connection

.

NOTE: 

For grounding requirements, follow the National

Electrical Code (NEC), state, and local regulations.

Starting the Unit

1. See 

Figure 3-1

. Press start button (A) to start fan.

Figure 3-1. Starting the Unit

2. See 

Figure 3-2

. Open valve (B).

Figure 3-2. Starting the Unit

(000145)

DANGER

Electrocution. In the event of electrical accident,  
immediately shut power OFF. Use non-conductive  
implements to free victim from live conductor. Apply  
first aid and get medical help. Failure to do so will  
result in death or serious injury

.

(000152)

DANGER

Electrocution. Verify electrical system is
properly grounded before applying power.
Failure to do so will result in death or serious
injury.

(000104)

DANGER

Electrocution. Water contact with a power 
source, if not avoided, will result in death 
or serious injury.

(000100a)

WARNING

Consult Manual. Read and understand manual
completely before using product. Failure to 
completely understand manual and product
could result in death or serious injury.

CAUTION

(000291)

Equipment damage. Do not attempt to start or operate 
a unit in need of repair or scheduled maintenance. 
Doing so could result in serious injury, death, or 
equipment failure or damage.

WARNING

WARNING

(000585)

Personal injury. Never direct air jet toward people or animals.
Shut unit OFF immediately if people or animals enter the
work area. Failure to do so could result in death or serious
injury.

 

WARNING

Personal injury. Keep people and pets away from work 
area. Failure to do so could result in death or serious 
injury.

(000420)

WARNING

(000584)

Personal injury. Only use water from controlled, reliable 
sources. Uncontrolled water could contain bacteria. Inhaling 
mist containing bacteria could result in death, or serious 
injury.

 

A

008856

B

008852

Содержание DF 2.2

Страница 1: ...ERENCE Register your Generac product at WWW GENERAC COM 1 888 GENERAC 1 888 436 3722 Owner s Manual For DF 2 2 Dust Suppression System For technical assistance contact www generacmobileproducts com Te...

Страница 2: ...nance and care of the generator ensures a minimum number of problems and keeps operating expenses at a minimum It is the operator s responsibility to perform all safety checks to verify that all maint...

Страница 3: ...3 Section 2 General Information Specifications 5 Component Locations 5 Setup 6 Water System Connection 6 Electrical Connection 6 Section 3 Operation Operation and Use Questions 7 Before Starting 7 St...

Страница 4: ...2 Owner s Manual for MDG25IF4...

Страница 5: ...dealer go to https www gener acmobileproducts com parts service find service When contacting an ASD about parts and service always supply the complete model and serial number of the unit as given on t...

Страница 6: ...82a WARNING Equipment damage Only qualified service personnel may install operate and maintain this equipment Failure to follow proper installation requirements could result in death serious injury an...

Страница 7: ...a Failure to do so could result in death or serious injury DANGER Electrocution DO NOT use the unit if electrical cord is cut or worn through Doing so will result in death or serious injury 000263a CA...

Страница 8: ...4 Owner s Manual for DF 2 2 Dust Suppression System Introduction and Safety This page intentionally left blank...

Страница 9: ...l min 14 5 1 44 1 0 5 4 21 8 1 74 1 5 6 6 29 1 98 2 0 7 5 36 3 2 25 2 5 8 5 Air Flow ft3 min mm3 min 295 90 Water Inlet Filter m 300 Nozzles Holder Stainless steel w 12 connection Tilting Angle 10 to...

Страница 10: ...Personal injury Only use water from controlled reliable sources Uncontrolled water could contain bacteria Inhaling mist containing bacteria could result in death or serious injury A B 008852 Table 1...

Страница 11: ...onductive implements to free victim from live conductor Apply first aid and get medical help Failure to do so will result in death or serious injury 000152 DANGER Electrocution Verify electrical syste...

Страница 12: ...nd the work site when moving or lifting the unit When lifting the unit attach any slings chains or hooks directly to the central lift point A Use forklift pockets B with care Avoid approaching the uni...

Страница 13: ...cing the unit always follow the instructions listed below 1 Verify unit power switch is OFF 2 Disconnect shore power from the unit 3 Disconnect water supply from the unit 4 Attach a DO NOT USE sign to...

Страница 14: ...antilimestone solution over night 3 Rinse nozzles 4 Reinstall nozzles Figure 4 3 Cleaning Nozzles General Troubleshooting This information is intended to be a check or verification for simple causes...

Страница 15: ......

Страница 16: ...hts reserved Specifications are subject to change without notice No reproduction allowed in any form without prior written consent from Generac Power Systems Inc Generac Mobile Products LLC 215 Power...

Отзывы: