6

                                       Owner’s Manual for DF 2.2 Dust Suppression System

General Information

Setup

Water System Connection

1.

See 

Figure 2-2

. Verify water valve (A) is closed.

Figure 2-2. Connecting Water Supply

2.

Connect water supply to water fitting (B). 

Electrical Connection

1.

See 

Figure 2-3

. Verify switch (A) is in OFF position.

 

Figure 2-3. Electrical Connection

2.

Connect  to  socket  (B)  240v  power  with  the
following requirements:

Extension cord must be marked “WA” or indicate it
is suitable for outdoor use.

Power  source  must  be  equipped  with  residual-
current device (RCD) protection.

Use  adequately  sized  extension  cords  of
appropriate length. See 

Table 1

 for recommended

cable size and length.

WARNING

(000584)

Personal injury. Only use water from controlled, reliable 
sources. Uncontrolled water could contain bacteria. Inhaling 
mist containing bacteria could result in death, or serious 
injury.

 

A

B

008852

Table 1 - Recommended Shore Power Cable 

Size and Length

Suggested Power Cables and Lengths

50 ft. (15.2 m) 10/3—(L5-20P – L5-20R)

100 ft. (30.5 m) 12/3—(5-15P – 5-15R)

(000145)

DANGER

Electrocution. In the event of electrical accident,  
immediately shut power OFF. Use non-conductive  
implements to free victim from live conductor. Apply  
first aid and get medical help. Failure to do so will  
result in death or serious injury

.

(000152)

DANGER

Electrocution. Verify electrical system is
properly grounded before applying power.
Failure to do so will result in death or serious
injury.

(000104)

DANGER

Electrocution. Water contact with a power 
source, if not avoided, will result in death 
or serious injury.

A

B

008853

Содержание DF 2.2

Страница 1: ...ERENCE Register your Generac product at WWW GENERAC COM 1 888 GENERAC 1 888 436 3722 Owner s Manual For DF 2 2 Dust Suppression System For technical assistance contact www generacmobileproducts com Te...

Страница 2: ...nance and care of the generator ensures a minimum number of problems and keeps operating expenses at a minimum It is the operator s responsibility to perform all safety checks to verify that all maint...

Страница 3: ...3 Section 2 General Information Specifications 5 Component Locations 5 Setup 6 Water System Connection 6 Electrical Connection 6 Section 3 Operation Operation and Use Questions 7 Before Starting 7 St...

Страница 4: ...2 Owner s Manual for MDG25IF4...

Страница 5: ...dealer go to https www gener acmobileproducts com parts service find service When contacting an ASD about parts and service always supply the complete model and serial number of the unit as given on t...

Страница 6: ...82a WARNING Equipment damage Only qualified service personnel may install operate and maintain this equipment Failure to follow proper installation requirements could result in death serious injury an...

Страница 7: ...a Failure to do so could result in death or serious injury DANGER Electrocution DO NOT use the unit if electrical cord is cut or worn through Doing so will result in death or serious injury 000263a CA...

Страница 8: ...4 Owner s Manual for DF 2 2 Dust Suppression System Introduction and Safety This page intentionally left blank...

Страница 9: ...l min 14 5 1 44 1 0 5 4 21 8 1 74 1 5 6 6 29 1 98 2 0 7 5 36 3 2 25 2 5 8 5 Air Flow ft3 min mm3 min 295 90 Water Inlet Filter m 300 Nozzles Holder Stainless steel w 12 connection Tilting Angle 10 to...

Страница 10: ...Personal injury Only use water from controlled reliable sources Uncontrolled water could contain bacteria Inhaling mist containing bacteria could result in death or serious injury A B 008852 Table 1...

Страница 11: ...onductive implements to free victim from live conductor Apply first aid and get medical help Failure to do so will result in death or serious injury 000152 DANGER Electrocution Verify electrical syste...

Страница 12: ...nd the work site when moving or lifting the unit When lifting the unit attach any slings chains or hooks directly to the central lift point A Use forklift pockets B with care Avoid approaching the uni...

Страница 13: ...cing the unit always follow the instructions listed below 1 Verify unit power switch is OFF 2 Disconnect shore power from the unit 3 Disconnect water supply from the unit 4 Attach a DO NOT USE sign to...

Страница 14: ...antilimestone solution over night 3 Rinse nozzles 4 Reinstall nozzles Figure 4 3 Cleaning Nozzles General Troubleshooting This information is intended to be a check or verification for simple causes...

Страница 15: ......

Страница 16: ...hts reserved Specifications are subject to change without notice No reproduction allowed in any form without prior written consent from Generac Power Systems Inc Generac Mobile Products LLC 215 Power...