TROUBLESHOOTING POINTS
17
H i g h P r e s s u r e W a s h e r
GENER
A
C
Generac 2250PSI High Pressure Washer
PROBLEM
CAUSE CORRECTION
Engine will not start; or starts
1. Low oil level.
1. Fill crankcase to proper level.
and runs rough.
2. Dirty air cleaner.
2. Clean or replace air cleaner.
3. Out of gasoline.
3. Fill fuel tank.
4. Stale gasoline.
4. Drain gas tank; fill with fresh fuel.
5. Spark plug wire not connected
5. Connect wire to spark plug.
to spark plug.
6. Bad spark plug.
6. Replace spark plug.
7. Water in gasoline.
7. Drain gas tank; fill with fresh fuel.
8. Overchoking.
8. Open choke fully and crank
engine.
9. Excessively rich fuel mixture.
9. Contact Generac service facility.
10. Intake valve stuck open or closed.
10. Contact Generac service facility.
11. Engine has lost compression.
11. Contact Generac service facility.
Engine shuts down during operation.
1. Out of gasoline.
1. Fill fuel tank.
2. Low oil level.
2. Fill crankcase to proper level.
Engine lacks power.
Dirty air filter.
Replace air filter.
Engine hunts or falters.
Choke is opened too soon.
Move choke to halfway position
until engine runs smoothly.