Safety Rules..........................................Inside Front Cover
Section 1 — General Information ..................................2

1.1 Introduction ............................................................2
1.2 Equipment Description ............................................2
1.3 Transfer Switch Data Plate ......................................2
1.4 Transfer Switch Enclosure ......................................2
1.5 Safe Use Of Transfer Switch ....................................2

Section 2 — Installation ....................................................3

2.1 Introduction to Installation ......................................3
2.2 Unpacking ................................................................3
2.3 Mounting ..................................................................3
2.4 Connecting Power Source and Load Lines................3

2.4.1  2-Pole Mechanism ..........................................3

2.5 Connecting Start Circuit Wires ................................4
2.6 Auxiliary Contacts ....................................................4

Section 3 — Operation ......................................................5

3.1 Functional Tests & Adjustments ..............................5
3.2 Manual Operation ....................................................5

3.2.1  Close to Normal Source Side ........................6
3.2.2  Close to Emergency Source Side ....................6
3.2.3  Return to Normal Source Side ......................6

3.3 Voltage Checks..........................................................6
3.4 Generator Tests Under Load ....................................7

Section 4 – Mounting Dimensions ................................8
Section 5 – Electrical Data ..............................................9
Section 6 – Exploded Views & Parts Lists ..................12
Section 7 – Warranty ......................................Back Cover

• Because jewelry conducts electricity, wearing it

may cause dangerous electrical shock. Remove all
jewelry (such as rings, watches, bracelets, etc.)
before working on this equipment.

• If work must be done on this equipment while

standing on metal or concrete, place insulative
mats over a dry wood platform. Work on this
equipment only while standing on such insulative
mats.

• Never work on this equipment while physically or

mentally fatigued.

• Keep the transfer switch enclosure door closed and

bolted at all times. Only qualified personnel
should be permitted access to the switch interior.

• In case of an accident caused by electric shock,

immediately shut down the source of electrical
power. If this is not possible, attempt to free the
victim from the live conductor but AVOID DIRECT
CONTACT WITH THE VICTIM. Use a
nonconducting implement, such as a rope or
board, to free the victim from the live conductor. If
the victim is unconscious, apply first aid and get
immediate medical help.

• When an automatic transfer switch is installed for

a standby generator set, the generator engine may
crank and start at any time without warning. To
avoid possible injury that might be caused by such
sudden start-ups, the system’s automatic start
circuit must be disabled before working on or
around the generator or transfer switch. For that
purpose, a SAFETY DISCONNECT is provided
inside the transfer switch. Always set that switch
to its MANUAL position before working on the
equipment. Then place a “DO NOT OPERATE” tag
on the transfer switch and on the generator.
Remove the Negative (Neg) or (–) battery cable.

Содержание 04635-0

Страница 1: ...Owner s Manual GTS W Type Automatic Transfer Switch 200 Amp 250 Volts Model 04635 0 POWER SYSTEMS INC This manual should remain with the unit...

Страница 2: ...urs must be isolated from the NORMAL utility power source by means of an approved transfer switch Failure to properly isolate the NORMAL and STANDBY power sources from each other may result in injury...

Страница 3: ...nsulative mats over a dry wood platform Work on this equipment only while standing on such insulative mats Never work on this equipment while physically or mentally fatigued Keep the transfer switch e...

Страница 4: ...llations The transfer switch consists of a solid state intelligence circuit a transfer mechanism and a control panel 1 3 TRANSFER SWITCH DATA DECAL A DATA DECAL is permanently affixed to the transfer...

Страница 5: ...EMERGENCY STANDBY power supplies before trying to connect power source and load lines to the transfer switch Supply voltages are extremely high and dangerous Contact with such high voltage power supp...

Страница 6: ...TART CIRCUIT WIRES Control system interconnections consist of UTILITY 1 and 2 LOAD 1 and 2 liquid cooled units only and leads 23 and 194 Control system interconnection leads must be run in a conduit t...

Страница 7: ...itch Note any options or accessories that might be installed and review their operation 3 2 MANUAL OPERATION Do NOT manually transfer under load Disconnect transfer switch from all power sources by ap...

Страница 8: ...CAL SHOCK 2 With an accurate AC voltmeter check for correct voltage Single phase utility supply Measure across ATS terminal lugs N1 and N2 N1 to NEUTRAL and N2 to NEUTRAL 3 When certain that UTILITY s...

Страница 9: ...uld be greater than 59 Hz Let the generator run under rated load for at least 30 minutes With unit running listen for unusual noises vibration overheating etc that might indicate a problem 5 When chec...

Страница 10: ...Systems Inc Section 4 Mounting Dimensions Generac GTS W Type Transfer Switch Mounting Dimensions Drawing No 0D3714 B 180 514 612 490 430 Values are in Millimeters Note Diameter of Mounting holes A is...

Страница 11: ...SPST ELECTRICAL RATINGS UTILITY 1 UTILITY 2 LOAD 2 23 194 CB2 NEUTRAL CONNECTION N1 N2 N3 T1 T2 T3 NEUTRAL LUG TRANSFER SWITCH UTILITY SUPPLY LOAD CUSTOMER 194 UTILITY 2 UTILITY 1 AC GENERATOR CONTRO...

Страница 12: ...2A 250Vac MIN SWITCH TYPE SPST ELECTRICAL RATINGS UTILITY 1 UTILITY 2 194 CB1 NEUTRAL CONNECTION N1 N2 T1 T2 E1 E2 NEUTRAL LUG TRANSFER SWITCH UTILITY SUPPLY LOAD CUSTOMER 194 23 UTILITY 2 UTILITY 1...

Страница 13: ...Generac Power Systems Inc 11 Section 5 Electrical Data Generac GTS W Type Transfer Switch Wiring Diagram 200 Amp 2 pole Switch Drawing No 0D3819...

Страница 14: ...12 Generac Power Systems Inc Section 6 Exploded Views and Parts List Generac GTS W Type Transfer Switch Transfer Switch Assembly 2 pole Drawing No 0D4406 E...

Страница 15: ...CREW HHTT M4 0 7 X 10 BP 15 063617 1 RELAY PNL 12VDC DPDT 10A 240VA 16 0C2454 2 SCREW TH FRM M6 1X16 N WA Z JS 17 0A1661 2 RIVET POP 156 X 160 164 20 18 0C4449A 1 ASS Y NTRL BL150 200A 19 0D3714 1 WEL...

Страница 16: ...lacement part s will void the warranty in its entirety 5 Damage related to rodent or insect infestation 6 Failures due but not limited to normal wear and tear accident misuse abuse negligence or impro...

Отзывы: