Generac Power Systems 04635-0 Скачать руководство пользователя страница 16

Part No. 0D4001

Revision C (10/17/03)

Printed in U.S.A.

Section 7 — Warranty

Generac GTS “W” Type Transfer Switch

GENERAC POWER SYSTEMS STANDARD TWO-YEAR LIMITED WARRANTY

FOR GENERAC TRANSFER SWITCH SYSTEMS

For a period of 2 (two) years from the date of sale, Generac Power Systems, Inc. will, at its option, repair or replace any
part(s) which, upon examination, inspection, and testing by Generac Power Systems or a Generac Power Systems
Authorized Warranty Service Dealer, is found to be defective under normal use and service, in accordance with the
warranty schedule set forth below. Any equipment that the purchaser/owner claims to be defective must be examined by
the nearest Generac Power Systems Authorized Warranty Service Dealer. All transportation costs under the warranty,
including return to the factory, are to be borne and prepaid by the purchaser/owner. This warranty applies only to
Generac Power Systems Transfer Switch applications, as Generac Power Systems, Inc. have defined Transfer Switch
application. 

WARRANTY SCHEDULE

YEAR ONE

— 100% (one hundred percent) coverage labor, and parts listed.

ALL COMPONENTS

YEAR TWO

— 100% (one hundred percent) coverage on parts listed.

ALL COMPONENTS — *PARTS ONLY

• A Generac Power Systems, Inc. Transfer Switch is highly recommended to be used in conjunction with the genset. If a

non Generac genset is substituted for use and directly causes damage to the Generac Transfer Switch, no warranty 
coverage shall apply.

• All warranty expense allowances 

are

subject to the conditions defined in Generac Power Systems Warranty, Policies, and

Procedures Flat Rate Manual.

• Units that have been resold 

are not

covered under the Generac Power Systems Warranty, as this Warranty 

is not

transferable.

THIS WARRANTY SHALL NOT APPLY TO THE FOLLOWING:

1. Any unit built/manufactured prior to January 1, 2002.
2. Unit enclosure is only covered against rust or corrosion the first year of the warranty provision.
3. Costs of normal maintenance i.e. tune-ups, associated part(s), adjustments, loose/leaking clamps, installation and start-up.
4. Use of Non-Generac replacement part(s) will void the warranty in its entirety.
5. Damage related to rodent or insect infestation
6. Failures due, but not limited to, normal wear and tear, accident, misuse, abuse, negligence, or improper installation or

sizing.

7. Failures caused by any external cause or act of God such as collision, fire, theft, freezing, vandalism, riot or wars, lightning,

earthquake, windstorm, hail, volcanic eruption, water or flood, tornado, hurricane, terrorist acts or nuclear holocaust.

8. Products that are modified or altered in a manner not authorized by Generac Power Systems in writing.
9. Any incidental, consequential or indirect damages caused by defects in materials or workmanship, or any delay in

repair or replacement of the defective part(s).

10. Failure due to misapplication, or misrepresentation.
11. Telephone, cellular phone, facsimile, internet access or other communication expenses.
12. Living or travel expenses of person(s) performing service, except as specifically included within the terms of a specific

unit warranty period.

13. Rental equipment used while warranty repairs are being performed.
14. Overtime labor.
15. Expenses related to “customer instruction” or troubleshooting where no manufacturing defect is found.
16. Overnight freight costs for replacement part(s).

THIS WARRANTY IS IN PLACE OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, SPECIFICALLY, GENERAC

POWER SYSTEMS MAKES NO OTHER WARRANTIES AS TO THE MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE. Some states do not allow limitations on how long an implied warranty lasts, so the above
limitation may not apply to you.

GENERAC POWER SYSTEMS ONLY LIABILITY SHALL BE THE REPAIR OR REPLACEMENT OF PART(S) AS STATED

ABOVE. IN NO EVENT SHALL GENERAC POWER SYSTEMS BE LIABLE FOR ANY INCIDENTAL, OR CONSEQUENTIAL
DAMAGES, EVEN IF SUCH DAMAGES ARE A DIRECT RESULT OF GENERAC POWER SYSTEMS, INC. NEGLIGENCE.

Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations may

not apply to you. Purchaser/owner agrees to make no claims against Generac Power Systems, Inc. based on negligence.

This warranty gives you specific legal rights. You also may have other rights that vary from state to state.

GENERAC

®

POWER SYSTEMS, INC. 

P.O. BOX 297

WHITEWATER, WI 5319087

Содержание 04635-0

Страница 1: ...Owner s Manual GTS W Type Automatic Transfer Switch 200 Amp 250 Volts Model 04635 0 POWER SYSTEMS INC This manual should remain with the unit...

Страница 2: ...urs must be isolated from the NORMAL utility power source by means of an approved transfer switch Failure to properly isolate the NORMAL and STANDBY power sources from each other may result in injury...

Страница 3: ...nsulative mats over a dry wood platform Work on this equipment only while standing on such insulative mats Never work on this equipment while physically or mentally fatigued Keep the transfer switch e...

Страница 4: ...llations The transfer switch consists of a solid state intelligence circuit a transfer mechanism and a control panel 1 3 TRANSFER SWITCH DATA DECAL A DATA DECAL is permanently affixed to the transfer...

Страница 5: ...EMERGENCY STANDBY power supplies before trying to connect power source and load lines to the transfer switch Supply voltages are extremely high and dangerous Contact with such high voltage power supp...

Страница 6: ...TART CIRCUIT WIRES Control system interconnections consist of UTILITY 1 and 2 LOAD 1 and 2 liquid cooled units only and leads 23 and 194 Control system interconnection leads must be run in a conduit t...

Страница 7: ...itch Note any options or accessories that might be installed and review their operation 3 2 MANUAL OPERATION Do NOT manually transfer under load Disconnect transfer switch from all power sources by ap...

Страница 8: ...CAL SHOCK 2 With an accurate AC voltmeter check for correct voltage Single phase utility supply Measure across ATS terminal lugs N1 and N2 N1 to NEUTRAL and N2 to NEUTRAL 3 When certain that UTILITY s...

Страница 9: ...uld be greater than 59 Hz Let the generator run under rated load for at least 30 minutes With unit running listen for unusual noises vibration overheating etc that might indicate a problem 5 When chec...

Страница 10: ...Systems Inc Section 4 Mounting Dimensions Generac GTS W Type Transfer Switch Mounting Dimensions Drawing No 0D3714 B 180 514 612 490 430 Values are in Millimeters Note Diameter of Mounting holes A is...

Страница 11: ...SPST ELECTRICAL RATINGS UTILITY 1 UTILITY 2 LOAD 2 23 194 CB2 NEUTRAL CONNECTION N1 N2 N3 T1 T2 T3 NEUTRAL LUG TRANSFER SWITCH UTILITY SUPPLY LOAD CUSTOMER 194 UTILITY 2 UTILITY 1 AC GENERATOR CONTRO...

Страница 12: ...2A 250Vac MIN SWITCH TYPE SPST ELECTRICAL RATINGS UTILITY 1 UTILITY 2 194 CB1 NEUTRAL CONNECTION N1 N2 T1 T2 E1 E2 NEUTRAL LUG TRANSFER SWITCH UTILITY SUPPLY LOAD CUSTOMER 194 23 UTILITY 2 UTILITY 1...

Страница 13: ...Generac Power Systems Inc 11 Section 5 Electrical Data Generac GTS W Type Transfer Switch Wiring Diagram 200 Amp 2 pole Switch Drawing No 0D3819...

Страница 14: ...12 Generac Power Systems Inc Section 6 Exploded Views and Parts List Generac GTS W Type Transfer Switch Transfer Switch Assembly 2 pole Drawing No 0D4406 E...

Страница 15: ...CREW HHTT M4 0 7 X 10 BP 15 063617 1 RELAY PNL 12VDC DPDT 10A 240VA 16 0C2454 2 SCREW TH FRM M6 1X16 N WA Z JS 17 0A1661 2 RIVET POP 156 X 160 164 20 18 0C4449A 1 ASS Y NTRL BL150 200A 19 0D3714 1 WEL...

Страница 16: ...lacement part s will void the warranty in its entirety 5 Damage related to rodent or insect infestation 6 Failures due but not limited to normal wear and tear accident misuse abuse negligence or impro...

Отзывы: