Generac Power Systems 005040-2 Скачать руководство пользователя страница 56

Part No. 0F5098

Revision B (04/26/05)

Printed in U.S.A.

Section 10 – Warranty

Guardian Liquid-cooled 25 kW Generator

GENERAC POWER SYSTEMS "TWO YEAR" LIMITED WARRANTY FOR GUARDIAN

®

"PREPACKAGED EMERGENCY AUTOMATIC STANDBY GENERATORS" 

For a period of two years from the date of original sale, Generac Power Systems, Inc. (Generac) warrants that its Guardian generator
will be free from defects in material and workmanship for the items and period set forth below. Generac will, at its option, repair or replace
any part which, upon examination, inspection and testing by Generac or a Guardian Authorized Warranty Service Dealer, is found to be
defective. Any equipment that the purchaser/owner claims to be defective must be examined by the nearest Guardian Authorized
Warranty Service Dealer. All transportation costs under the warranty, including return to the factory, are to be borne and prepaid by the
purchaser/owner. This warranty applies only to Generac Guardian prepackaged emergency automatic standby generators sold and
rated for use in "Standby" applications.

WARRANTY SCHEDULE

YEARS ONE and TWO - 100% (one hundred percent) transferable coverage on Labor and Part(s) listed (proof of purchase and main-
tenance is required):
Engine - All Components 
Alternator - All Components 
Transfer System - All Components 
Steel enclosures are warranted against rusting for the first year of ownership only. Damage caused after receipt of generator is the
responsibility of the owner and is not covered by this warranty. Nicks, scrapes, dents or scratches to the painted enclosure should be
repaired promptly by the owner.
All warranty expense allowances are subject to the conditions defined in Guardian's Warranty Policies, Procedures and Flat Rate
Manual.

THIS WARRANTY SHALL NOT APPLY TO THE FOLLOWING:

• Guardian generators that utilize non-Guardian/Generac replacement parts.
• Guardian generators utilizing non-Guardian/Generac automatic transfer switches.
• Repairs or diagnostics performed by individuals other than Guardian/Generac authorized dealers not authorized in writing by

Generac Power Systems.

• Any Guardian generators used as rental or trailer mounted applications.
• Units used for prime power in place of existing utility power where utility power is present or in place of utility power where utility

power service does not normally exist.

• Costs of normal maintenance, adjustments, installation and start-up.
• Steel enclosures that are rusting due to the improper installation, location in a harsh or saltwater environment or scratched where

integrity of paint applied is compromised.

• Failures caused by any contaminated fuels, oils, coolants or lack of proper fluid amounts.
• Failures due, but not limited, to normal wear and tear, accident, misuse, abuse, negligence or improper installation. As with all

mechanical devices, the Generac engines need periodic part(s) service and replacement to perform well. This warranty will not
cover repair when normal use has exhausted the life of a part(s) or engine.

• Failures caused by any external cause or act of God, such as collision, theft, vandalism, riot or wars, nuclear holocaust, fire, 

freezing, lightning, earthquake, windstorm, hail, volcanic eruption, water or flood, tornado or hurricane.

• Damage related to rodent and/or insect infestation.
• Products that are modified or altered in a manner not authorized by Generac in writing.
• Any incidental, consequential or indirect damages caused by defects in materials or workmanship, or any delay in repair or 

replacement of the defective part(s).

• Failure due to misapplication.
• Telephone, cellular phone, facsimile, internet access or other communication expenses.
• Living or travel expenses of person(s) performing service, except as specifically included within the terms of a specific unit warranty

period.

• Expenses related to "customer instruction" or troubleshooting where no manufacturing defect is found.
• Rental equipment used while warranty repairs are being performed.
• Costs incurred for equipment used for removal and/or reinstallation of generator, (i.e.; cranes, hoists, lifts, etc.) 
• Overnight freight costs for replacement part(s).
• Overtime labor.
• Starting batteries, fuses, light bulbs and engine fluids.

THIS WARRANTY IS IN PLACE OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED. SPECIFICALLY, GENERAC MAKES
NO OTHER WARRANTIES AS TO THE MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some states do not
allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you.
GENERAC'S ONLY LIABILITY SHALL BE THE REPAIR OR REPLACEMENT OF PART(S) AS STATED ABOVE. IN NO EVENT
SHALL GENERAC BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES, EVEN IF SUCH DAMAGES ARE A
DIRECT RESULT OF GENERAC'S NEGLIGENCE. Some states do not allow the exclusion or limitation of incidental or consequential
damages, so the above limitation may not apply to you.
This warranty gives you specific legal rights. You also have other rights from state to state.

GENERAC

®

POWER SYSTEMS, INC.

P.O. BOX 297 

WHITEWATER, WI 53190

Revision (02/01/05)

Содержание 005040-2

Страница 1: ...Owner s Manual ONLY QUALIFIED ELECTRICIANS OR CONTRACTORS SHOULD ATTEMPT INSTALLATION This manual should remain with the unit Liquid cooled Prepackaged Standby Generators Model Number 005040 2 25kW...

Страница 2: ...tential explosion hazard This symbol points out potential fire hazard This symbol points out potential electrical shock hazard The operator is responsible for proper and safe use of the equipment Gene...

Страница 3: ...od 9 2 6 Total Circuit Isolation Method 10 2 7 Grounding the Generator 10 2 8 Generator AC Neutral Connections 10 2 9 Using an Engineered GTS Transfer Switch 10 2 10 Battery Installation 11 2 11 Prepa...

Страница 4: ...ven death For that reason adequate ventilation must be provided Keep hands feet clothing etc away from drive belts fans and other moving or hot parts Never remove any drive belt or fan guard while the...

Страница 5: ...can conduct electricity resulting in electric shock or may get caught in moving components causing injury FIRE HAZARDS Keep a fire extinguisher near the generator at all times Do NOT use any carbon t...

Страница 6: ...ect the switch at all times against excessive moisture dust dirt lint construction grit and cor rosive vapors If a transfer switch is not included one may be pur chased separately from a Generac Autho...

Страница 7: ...cally shut down under the fol lowing conditions low oil pressure high coolant tem perature engine overspeed low coolant level or over crank Figure 1 3 Figure 1 3 Engine Protective Devices 1 7 1 LOW OI...

Страница 8: ...ck cartons with the proper side up as noted on the shipping carton 1 8 2 INSPECTION Upon delivery carefully inspect the generator for any damage that may have occurred during shipment If loss or damag...

Страница 9: ...2 5 Install brass hose fitting into Port 2 6 Install pipe plug into Port 1 7 Connect carburetor gas hose to brass fitting 8 Tighten all clamps and plugs 9 Make sure fuel supply is of the proper pressu...

Страница 10: ...ll phases of operation including engine start up and load transfer 2 1 STANDBY GENERATOR INSTALLATION Connecting this generator to an electrical sys tem normally supplied by an electric utility shall...

Страница 11: ...enerator as close as possible to the fuel supply to reduce the length of piping HOWEVER REMEMBER THAT LAWS OR CODES MAY REG ULATE THE DISTANCE 2 3 GENERATOR MOUNTING AND SUPPORT Retain the generator c...

Страница 12: ...ng is recommended only at the main service entrance If the neutral wire is grounded and one of the phase loads becomes grounded the excessive current opens the load circuit breaker or collapses the ge...

Страница 13: ...g Where electrolyte contacts the skin wash it off immediately with water Where electrolyte contacts the eyes flush thor oughly and immediately with water and seek med ical attention and Spilled electr...

Страница 14: ...em for leaks and other problems See Specifications and Coolant 2 11 6 BELT TENSION Check the engine fan belt tension and condition prior to placing the unit into service and at recommended intervals B...

Страница 15: ...15 AMP FUSE This fuse protects the control console s DC control circuit against electrical overload and is located inside the control panel If the fuse has melted open because of an overload engine c...

Страница 16: ...the factory during final testing of the generator and should not be adjusted If however adjustments are necessary the following procedure should be followed Figure 3 2 and Section 3 8 1 Move dip swit...

Страница 17: ...sfer switch using whatever means provided such as a utility main line circuit breaker The utility power source now powers the loads 3 6 AUTOMATIC OPERATION To set the system for fully automatic operat...

Страница 18: ...generator alternator output frequency and is factory pre set for 60 Hz Switch Position 2 Selects the type of transfer switch and is factory pre set for an automatic trans fer switch ATS Switch Positio...

Страница 19: ...ts studs to specifications in the tightening sequence shown First pass 7 10 N m 5 7 lb ft Final pass 26 38 N m 19 28 lb ft Figure 4 1 Intake Manifold Installation 4 4 CYLINDER HEAD PROCEDURE 1 Positio...

Страница 20: ...iodically remove radiator pressure cap only when engine has cooled down to make sure the coolant recovery system is functioning properly Coolant should be at bottom of radiator filler neck If coolant...

Страница 21: ...f old filter 5 Apply light coating of new engine oil to seal of new oil filter Install FILTER and tighten by hand only DO NOT OVER TIGHTEN 6 Remove OIL FILL CAP Add recommended oil see SPECIFICATIONS...

Страница 22: ...9 3 BATTERY MAINTENANCE The battery should be inspected per Section 4 7 Scheduled Maintenance The following procedure should be followed for inspection 1 Inspect the battery posts and cables for tight...

Страница 23: ...battery cable The battery charger must be turned off BEFORE removing the battery cable to prevent an over current condi tion from burning out sensitive control panel components and circuits Following...

Страница 24: ...Correct as necessary 5 Check the natural gas delivery system on gas engine driven units Tighten connections as necessary 6 Check the air inlets and outlets for debris Clean as necessary 7 Check the b...

Страница 25: ...d abnormal operating conditions Correct as necessary 14 Start and exercise the unit at full rated load use a load bank if the site load is not enough for at least 2 hours looking for leaks loose conne...

Страница 26: ...gs 3 Clean regap or replace plugs Engine starts then shuts down 1 Engine oil level is low 1 Check oil and add oil as needed 2 Engine is overheated 2 Check cooling system for leaks 3 Defective Low Oil...

Страница 27: ...Generac Power Systems Inc 25 Section 6 Notes Guardian Liquid cooled 25 kW Generator...

Страница 28: ...26 Generac Power Systems Inc Section 7 Electrical Data Guardian Liquid cooled 25 kW Generator Wiring Diagram 2 5L Engine 15kW 20kW units Drawing No 0F1411 A...

Страница 29: ...Generac Power Systems Inc 27 Section 7 Electrical Data Guardian Liquid cooled 25 kW Generator Wiring Diagram 2 5L Engine 15kW 20kW units Drawing No 0F1411 A...

Страница 30: ...28 Generac Power Systems Inc Section 7 Electrical Data Guardian Liquid cooled 25 kW Generator Electrical Schematic 2 5L Engine 15kW 20kW units Drawing No 0F1413 A...

Страница 31: ...Generac Power Systems Inc 29 Section 7 Electrical Data Guardian Liquid cooled 25 kW Generator Electrical Schematic 2 5L Engine 15kW 20kW units Drawing No 0F1413 A...

Страница 32: ...30 Generac Power Systems Inc Section 7 Electrical Data Guardian Liquid cooled 25 kW Generator Wiring Diagram 2 5L Engine 25kW unit Drawing No 0E9982 C...

Страница 33: ...Generac Power Systems Inc 31 Section 7 Electrical Data Guardian Liquid cooled 25 kW Generator Wiring Diagram 2 5L Engine 25kW unit Drawing No 0E9982 C...

Страница 34: ...32 Generac Power Systems Inc Section 7 Electrical Data Guardian Liquid cooled 25 kW Generator Electrical Schematic 2 5L 25kW unit Drawing No 0E9983 C...

Страница 35: ...Generac Power Systems Inc 33 Section 7 Electrical Data Guardian Liquid cooled 25 kW Generator Electrical Schematic 2 5L 25kW unit Drawing No 0E9983 C...

Страница 36: ...25 kW Generator Mounting Base Drawing No 0E9964 E 28 ENGINE BLOCK 5 CARRIER REAR BEARING 14 15 13 3 BOTTOM PANEL 3 2 12 4 1 11 15 14 13 33 2 3 12 11 36 35 10 10 3 1 6 8 9 3 22 21 27 23 1 25 26 29 34...

Страница 37: ...4 052259 4 WASHER FLAT M12 15 052891 4 SCREW HHC M12 1 75 X 80 G8 8 16 0536210261 1 ASSY WIRE 0 12 00 17 074906 1 SCREW HHTT M6 1 0 X 20 BP 18 077483 REF BATT 12VDC 75 AH 26 NOT SHOWN 19 0E9941 1 HOLD...

Страница 38: ...0E9720 J 35 NUTS ITEM 26 USE LOCTITE ON PANEL FOR ACCESS COVER CABLE WELD STUD UNDER ROOF 17 GROUND WIRE FASTENER TO SECURE USE DOOR LATCH NOTE 6 18 38 11 31 7 9 24 1 4 26 2 18 8 29 2 12 11 14 13 10 5...

Страница 39: ...72J 2 ACSTC INSLTN 1 5L RR CRNR BOTTOM 29 0E0072L 2 ACSTC INSLTN 1 5L SIDE BRC PNL 30 0E0072M 2 ACSTC INSLTN 1 5L SIDE DR PNL 31 0D2023 1 TRIM VINYL SELF GRIPPING 80 LG 33 0E0072Q 2 ACSTC INSLTN 1 5L...

Страница 40: ...4 26 10 14 1 29 24 31 33 52 50 41 33 4 48 13 27 66 36 54 A 23 65 37 35 2 7 3 35 9 34 43 34 21 35 17 30 34 22 3 35 16 36 34 5 56 0 12 14 11 64 54 38 18 39 Section 8 Exploded Views and Parts Guardian Li...

Страница 41: ...13 SCREW PHTT M4 0 7 X 16 ZYC 35 022264 22 WASHER LOCK 8 M4 36 0C2265 7 SCREW PHTT M4 0 7 X 12 ZYC 37 023965 2 SCREW RHM 8 32 X 3 8 38 039782 1 BRKT MTG CB BQ ITEM PART NO QTY DESCRIPTION 39 0A2077 1...

Страница 42: ...40 Generac Power Systems Inc Section 8 Exploded Views and Parts Guardian Liquid cooled 25 kW Generator Control Panel Drawing No 0F1378 F...

Страница 43: ...CONTROL HSB 2 5L FORD 33 022097 3 WASHER LOCK M6 1 4 34 0C2212 9 SCREW PHTT M4 0 7 X 16 ZYC 35 022264 22 WASHER LOCK 8 M4 36 0C2265 13 SCREW PHTT M4 0 7 X 12 ZYC ITEM PART NO QTY DESCRIPTION 37 023965...

Страница 44: ...ND 5 3 22 17 68 15 19 10 38 22 31 0 HSG 20 3 47 45 20 49 1 16 39 50 34 35 65 33 57 18 37 18 20 16 38 RADIATOR CAP 62 TO 58 39 STEPPER MOTOR UNITS ONLY 17 12 A 11 67 24 23 61 Section 8 Exploded Views a...

Страница 45: ...E9680 1 GASKET 2 5L FORD EXHAUST MAN 34 0E9609 1 MANIFOLD EXHAUST MACHINED ITEM PART NO QTY DESCRIPTION 35 0E9930 1 HEAT SHIELD EXHAUST MANIFOLD 36 049821 3 SCREW SHC M8 1 25 X 30 G12 9 37 0E9747 1 ST...

Страница 46: ...LVE 12 13 28 1 8 20 33 31 32 17 34 26 6 38 30 16 25 24 18 4 29 15 9 5 27 6 4 CARBURETOR ASSY 0E1028A I N 19 CONVERSION 35 41 OUT 2 PORT L P VAPOR 3 40 1 11 3 40 7 2 6 11 Section 8 Exploded Views and P...

Страница 47: ...CARBURETOR GASKET 21 091526 4 SCREW PPHM M5 0 8 X 12 ZNC 22 049226 4 WASHER LOCK M5 23 026307 1 ELBOW 90D STREET 3 4 24 062522 1 STUD TH 1 4 20 X 3 G2 ZNC FULL 25 022127 1 NUT HEX 1 4 20 STEEL 26 022...

Страница 48: ...Power Systems Inc 3 LOCKTIGHT LOCKTIGHT 7 15 17 8 7 6 18 4 16 LEADS 5 2 9 13 21 19 20 14 10 11 12 30 1 31 Section 8 Exploded Views and Parts Guardian Liquid cooled 25 kW Generator Alternator Drawing N...

Страница 49: ...1 REVCOR FAN 10 75 X 2 W PRESS DIS 7 046526 8 WASHER LOCK M10 8 051755 4 SCREW HHC M10 1 5 X 16 G8 8 9 04576100BK 4 STUD M14 2 0 X 490 G5 ZINC 3 0L FORD 2 5L FORD 04576100BF 4 STUD M14 2 0 X 540 G5 Z...

Страница 50: ...C M6 1 0 X 16 G8 8 14 022097 4 WASHER LOCK M6 1 4 15 022473 8 WASHER FLAT 1 4 M6 ZINC 16 049813 4 NUT HEX M6 X 1 0 G8 YEL CHR 17 039253 2 SCREW HHC M8 1 25 X 20 G8 8 18 045771 2 NUT HEX M8 1 25 G8 YEL...

Страница 51: ...1 ASSY CARBURETOR LINKAGE ROD 12 0A7106 1 BRACKET STEPPER MOTOR 13 074031 AR LIQUID NEOPRENE 14 029333A 1 TIE WRAP 7 4 X 19 BLK UL 15 022507 2 SCREW HHC 1 4 20 X 1 2 G5 16 022473 2 WASHER FLAT 1 4 ZI...

Страница 52: ...060035 4 SPACER 41 X 75 X 87 ST ZNC ITEM PART NO QTY DESCRIPTION 14 0F0127 1 HOSE UPPER RADIATOR 174MM TAL 15 0E9833 1 HOSE 2 5L FORD LOWER RADIATOR 16 035461 1 BARBED STR 1 4NPT X 3 8 17 069860C 1 HO...

Страница 53: ...Generac Power Systems Inc 51 Section 9 Installation Diagram Guardian Liquid cooled 25 kW Generator Installation Diagram Drawing No 0F1020 A...

Страница 54: ...enerac may deny any and or all warranty coverage or responsibility if your engine or a part component thereof has failed due to abuse neglect improper maintenance or unap proved modifications or the u...

Страница 55: ...to Subsection 4 below Any such emissions related part repaired or replaced under the ECS Warranty shall be warranted for the remainder of the ECS Warranty Period prior to the first scheduled replaceme...

Страница 56: ...losures that are rusting due to the improper installation location in a harsh or saltwater environment or scratched where integrity of paint applied is compromised Failures caused by any contaminated...

Отзывы: