Generac Power Systems 004945-1 Скачать руководство пользователя страница 15

  

13

I

TEM PART 

NO.  QTY. 

DESCRIPTION

 1 

0C22

3

7 1 

TRAN

S

FER 

S

W-H

S

B 100A 2P 250V

 

0E7886H 

CB 0100A 2P 240V 

S

 BQ2 LB

 

3

 0E78

9

BRKT CB MTG BACK

 4 

0E

99

06 1 

BRACKET, 

DI

S

CONNECT 

S

WITCH 100A

 5 

06

33

78 8 

HOLDER, 

CABLE 

TIE

 6 

0D

3

728 1 

S

WITCH TOG 

S

P

S

T 15A @ 125V

 7 

0E

9999

 1 

DECAL 

S

ERVICE DI

S

CONNECT 

S

WITCH

 8 

04

9

81

3

 

NUT HEX M6 X 1.0 G8 YEL CHR

 

9

 0E652

3

 

GROUND BAR (5)4-14 AWG CONN

 10 

***

 06

3

617 

RELAY PNL 12VDC DPDT 10A@240VA

 11 

***

 0D2806 

FU

S

EBLOCK 

3

0A 600V 2PO

S

 W/

S

Q

 12 

07

3

5

9

0A 4 

FU

S

E 5A X BU

SS

 1

3

 

***

 

047822 

BLOCK TERM 20A 7 X 6 X 1100V

  14 

0A1661 

RIVET POP .156 X .675 AL

 15 

0C444

9

 1 

A

SS

’Y-NTRL BL 150-200A

 16 

0

9

0

3

88 2 

S

CREW HHTT M6-1.0 X 12 ZINC

 17 

0E147

3

 1 

WELDMENT 

TRAN

S

FER 

S

WITCH BOX

 18 

0E

99

07 1 

COVER 

IN

S

IDE XFER 

S

WITCH BOX

  1

9

 0E1477 

COVER 

TRAN

S

FER 

S

WITCH BOX

 20 

0F0668 

DECALTRAN

S

FER 

S

WITCH 

 21 

0E

3

070 1 

S

UBPLT XFER 

S

W H

S

B

 22 

0E

9

7

3

4 REF 

DECAL 

S

WITCH RATING

  2

3

 0E

3

484 

DECAL WARN MANUAL OPER HANDLE

 24 

0E

3

485 1 

DECAL 

S

ERVICE DI

S

CONNECT

  25 

067210A 

DECAL GROUND LUG (NOT 

S

HOWN)

 26 

0A

9

457 1 

DECAL 

NEUTRAL

 27 

0D

3

587 1 

DECAL 

FU

S

E REPLACEMENT

 28 

0A25

9

5 1 

DECAL 

TERMINAL 

S

TRIP

  2

9

 0F0776 

DECAL 

TE

S

S

EQ. 2P T

S

 H

S

 

3

R

 

3

0 081221 

DECAL-UL 

LI

S

T H

S

B

 

3

1 045764 

S

CREW HHTT M4-0.7 X 8 BP

 

3

2 074

9

08 2 

S

CREW HHTT M5-0.8 X 10 BP

 

33

 06684

9

B 2 

S

CREW HHTT M5-0.8 X 8 BP

 

3

4 0C

399

2 2 

S

CREW HHTT M4-0.7 X 16 BP

 

3

5 02657

9

 2 

WA

S

HER 

S

HAKEPROOF EXT #8 

S

TEEL

 

3

6 0E721

3

 2 

S

CREW THUMB 1/4-20 X 1/2 W/

S

HLD

 

3

7 02247

3

 8 

WA

S

HER FLAT 1/4-M6 ZINC

 

3

8 0220

9

7 4 

WA

S

HER LOCK M6-1/4

 

39

 0E

99

87 1 

WIRE 

HARNE

SS

 H

S

B (NOT 

S

HOWN)

 40 

0E61

93

 1 

BRACKET 

ARM 

EXTENDER

 41 

064526 

S

CREW HWH

S

 #6-25 X 

3

/8 ZNC

 42 

**

 

0E6155 

ARM EXTENDER PIN

  4

3

 

0

3

6

933

 6 

S

CREW PPHM #10-

3

2 X 

3

/8

 44 

 

0770

33

 6 

LUG 

S

LDL

SS

 1/0-#14X

9

/16 AL/CU

 45 

0C8

3

08 1 

DECAL 

TERMINAL 

S

HOCK HAZARD

 46 

022152 

WA

S

HER LOCK #10

 47 

0

9

12

9

70085 1  WIRE 

A

SS

Y 2AWG 100A 2-P T/

S

 N1A

 48 

0

9

12

9

70086 1  WIRE 

A

SS

Y 2AWG 100A 2-P T/

S

 N2A

  4

9

 

0

9

5282 1 

DECAL 

LIVE-CIRCUIT

 50 

0F2710 

DECAL 

XFER 

S

WITCH DATA 

S

E 100A

 51 

06684

9

 4 

S

CREW HHTT M5-0.8 X 16

 52 

0E6

3

0

3

 

WIRE – A

  5

3

 0E6

3

0

3

WIRE – B

 54 

0E6

3

0

3

WIRE – E1

***

 

S

UPPLIED WITH WIRE HARNE

SS

 ITEM #

39

**

  

S

UPPLIED WITH TRAN

S

FER 

S

WITCH (ITEM #1)

Section 6 — Exploded Views and Parts List

ATS “HS” Type Transfer Switch

100A Transfer Switch Assembly – Drawing No. 0F0466$-D

Содержание 004945-1

Страница 1: ...Automatic Transfer Switch Owner s Manual ATS Service Entrance HS Type Transfer Switch Models 005036 0 100 Amp 250 Volts and 004945 1 200 Amp 250 Volts This manual should remain with the unit...

Страница 2: ...ymbol points out potential fire hazard This symbol points out potential electrical shock hazard GENERAL HAZARDS Any AC generator that is used for backup power if a NORMAL UTILITY power source failure...

Страница 3: ...t may cause dangerous electrical shock Remove all jew elry such as rings watches bracelets etc before working on this equipment If work must be done on this equipment while standing on metal or concre...

Страница 4: ...ches Figure 1 1 are used with a single phase system when the single phase NEUTRAL line is to be connected to a Neutral Lug and is not to be switched Solderless screw type terminal lugs are standard Sw...

Страница 5: ...rom the switch prior to installation 2 3 MOUNTING Mounting dimensions for the transfer switch enclo sure are in this manual Enclosures are typically wall mounted See Installation Diagram Section 5 Han...

Страница 6: ...s for this wiring depends on the length of the wire as recommended below MAXIMUM WIRE LENGTH RECOMMENDED WIRE SIZE 460 feet 140m No 18 AWG 461 to 730 feet 223m No 16 AWG 731 to 1 160 feet 354m No 14 A...

Страница 7: ...osition of the switch by observing the position of the manual operation handle in Figure 3 1 If the handle is DOWN the contacts are closed in the EMERGENCY STANDBY position No further action is requir...

Страница 8: ...governed speed may require adjustment If no load frequency is correct but voltage is not the voltage regulator may require adjustment 3 4 GENERATOR TESTS UNDER LOAD 1 Set the generator s main circuit...

Страница 9: ...79 5mm 7 07 0A 0A6599tv 561mm 22 09 34mm 1 34 KNOCKOUT SUITABLE FOR 1 1 1 4 1 1 2 CONDUIT SIZE KNOCKOUT SUITABLE FOR 3 4 1 CONDUIT SIZE MOUNTING HOLES 6 3mm 0 25 PADLOCK CUSTOMER SUPPLIED LOCATION 0A6...

Страница 10: ...N1 DISCONNECT CONNECTION IN PANELBOARD OR RETROFIT NEW INSTALLATION NEUTRAL BAR GROUND BAR BONDING SOCKET METER UTILITY ALTERNATOR FROM 44 11 STATOR 33 22 GROUND BAR E1 T2 LOCAL ELECTRICAL CODES MEET...

Страница 11: ...TIONAL LOCAL CODES EXISTING WIRES TO PANELBOARD SEE ABOVE NOTE E1 INSULATED SPLICING CONNECTOR OR NEW WIRES CAN BE PULLED FROM ATS PANELBOARD UTILITY METER SOCKET LICENSED ELECTRICIAN AND MUST STATOR...

Страница 12: ...10 Section 5 Electrical Data ATS HS Type Transfer Switch Wiring Diagram Schematic Drawing No 0F0015 A...

Страница 13: ...11 Section 5 Electrical Data ATS HS Type Transfer Switch Wiring Diagram Schematic Drawing No 0F0015 A...

Страница 14: ...B E1 B A 30A 600V D2806 T A 63378 T 63378 T A 63378 T INSIDE LEFT SIDE INSIDE RIGHT SIDE 19 22 50 26 17 16 0A6599tv 0A6599tv 0A6599tv 0A9457 15 43 31 POWER TERMINAL LUG ASSY TIGHTEN ITEM 43 24 30 IN...

Страница 15: ...UTRAL 27 0D3587 1 DECAL FUSE REPLACEMENT 28 0A2595 1 DECAL TERMINAL STRIP 29 0F0776 1 DECAL TEST SEQ 2P TS HS 3R 30 081221 1 DECAL UL LIST HSB 31 045764 6 SCREW HHTT M4 0 7 X 8 BP 32 074908 2 SCREW HH...

Страница 16: ...G ASSEMBLY 35 34 9 28 14 11 31 12 47 1 0A6599tv 0A6599tv 0A6599tv 30A 600V D2806 T 63378 T B B INSIDE RIGHT SIDE INSIDE LEFT SIDE 22 18 4 55 19 46 27 31 11 12 26 17 0C4449A T Replace with UL listed fu...

Страница 17: ...PER HANDLE 24 0E3485 1 DECAL SERVICE DISCONNECT 25 067210A 1 DECAL GROUND LUG NOT SHOWN 26 0A9457 1 DECAL NEUTRAL 27 0D3587 1 DECAL FUSE REPLACEMENT 28 0A2595 1 DECAL TERMINAL STRIP 29 0E7109 1 DECAL...

Страница 18: ...16 Generac Power Systems Inc Section 7 Notes ATS HS Type Transfer Switch...

Страница 19: ...Generac Power Systems Inc 17 Section 7 Notes ATS HS Type Transfer Switch...

Страница 20: ...the prompt that describes the brand name of the generator THIS WARRANTY IS IN PLACE OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED SPECIFICALLY GENERAC MAKES NO OTHER WARRANTIES AS TO THE MERCHANTABILI...

Отзывы: