background image

  

19

 ELECTRICAL HAZARDS 

• The generator covered by this manual produces 

dangerous electrical voltages and can cause fatal 
electrical shock. Avoid contact with bare wires, ter-
minals, connections, etc., while the unit is running. 
Ensure all appropriate covers, guards and barriers 
are in place before operating the generator. If work 
must be done around an operating unit, stand on 
an insulated, dry surface to reduce shock hazard.

• Do not handle any kind of electrical device while 

standing in water, while barefoot, or while hands or 
feet are wet. DANGEROUS ELECTRICAL SHOCK 
MAY RESULT.

• During installation onto the vehicle, properly 

ground (bond) the generator either by solid mount-
ing to the vehicle frame or chassis, or by means of 
an approved bonding conductor. DO NOT connect 
the bonding conductor to any generator part that 
might be removed or disassembled during routine 
maintenance. If the grounding conductor must be 
replaced, use only a flexible conductor that is of 
No. 8 American Wire Gauge (AWG) copper wire 
minimum.

•  If the vehicle electrical circuits can be powered by 

any other source of electricity (such as a “dockside” 
power receptacle), there must be no possibility of 
connecting the different power sources to the vehi-
cle circuits at the same time. The dockside (utility) 
power source must be positively isolated from the 
vehicle circuits whenever the generator is operat-
ing. Failure to isolate the vehicle circuits from 
the dockside power supply when the generator is 
running may result in damage to the generator or 
serious injury or death to dockside (utility) power 
workers due to backfeed of electrical energy.

•  In case of accident caused by electric shock, imme-

diately shut down the source of electrical power. 
If this is not possible, attempt to free the victim 
from the live conductor. AVOID DIRECT CONTACT 
WITH THE VICTIM. Use a nonconducting imple-
ment, such as a rope or board, to free the victim 
from the live conductor. If the victim is uncon-
scious, apply first aid and get immediate medical 
help.

• Never wear jewelry when working on this equip-

ment. Jewelry can conduct electricity resulting in 
electric shock, or may get caught in moving com-
ponents causing injury.

 FIRE HAZARDS 

• For fire safety, the generator must be installed 

and maintained properly. Installation always must 
comply with applicable codes, standards, laws 
and regulations. Adhere strictly to local, state and 
national electrical and building codes. Comply 
with regulations the Occupational Safety and 
Health Administration (OSHA) has established. 
Also, ensure that the generator is installed in 
accordance with the manufacturer’s instructions 
and recommendations. Following proper installa-
tion, do nothing that might alter a safe installation 
and render the unit in noncompliance with the 
aforementioned codes, standards, laws and regula-
tions.

• Keep a fire extinguisher in the vehicle at all times. 

Extinguishers rated “ABC” by the National Fire 
Protection Association are appropriate for use on 
the recreational vehicle generator electrical system. 
Keep the extinguisher properly charged and be 
familiar with its use. If ther are any questions per-
taining to fire extinguishers, consult the local fire 
department.

 EXPLOSION HAZARDS 

• Do not smoke around the generator. Wipe up any 

fuel or oil spills immediately. Ensure that no com-
bustible materials are left in the generator com-
partment, or on or near the generator, as FIRE or 
EXPLOSION may result. Keep the area surround-
ing the generator clean and free from debris.

•  Gasoline is extremely FLAMMABLE and its vapors 

are EXPLOSIVE. Do not permit smoking, open 
flame, sparks or any source of heat in the vicinity 
while handling gasoline. Comply with all laws gov-
erning the storage and handling of gasoline.

•  Fuel lines must be properly installed and fastened, 

and free of leaks. There must be no possibility of 
gasoline vapors entering the vehicle interior.

•  It is  required that an approved, flexible, noncon-

ductive fuel line be installed between the generator 
fuel connection point and rigid fuel lines.

Safety Rules

Recreational Vehicle Generator

Содержание 004701-0

Страница 1: ...Owner s Manual and Installation Instructions Air cooled Recreational Vehicle Generators Model 004701 0 QUIETPACT 40LP This manual should remain with the unit...

Страница 2: ...nt and the safety of all vehicle occupants We strongly recom mend that the operator read this manual and thor oughly understand all instructions before using this equipment We also strongly recommend...

Страница 3: ...park Plug 12 3 6 Clean Spark Arrestor 12 3 7 Cleaning the Generator 13 3 8 Battery Maintenance 13 3 9 Major Service Manual 14 3 10 Exercising the Generator 14 3 11 Out of Service Procedure 14 3 12 Adj...

Страница 4: ...NG OR HAS BEEN DAMAGED SYMPTOMS OF CARBON MONOXIDE POISONING ARE a inability to think coherently b nausea c vomiting d twitching muscles e throbbing temples f dizziness g headaches h weak ness and i s...

Страница 5: ...nance If the grounding conductor must be replaced use only a flexible conductor that is of No 8 American Wire Gauge AWG copper wire minimum In case of accident caused by electric shock imme diately sh...

Страница 6: ...ILY AIR FILTER CLEAN PREFILTER EVERY 100 HOURS REPLACE ELEMENT EVERY 250 HOURS OIL OIL FILTER CHANGE EVERY 100 IF NECESSARY EVERY 500 HOURS HOURS REPLACE PLUGS PLUGS EVERY 100 INSPECT CLEAN SPARK PLUG...

Страница 7: ...uire more watts of power or amps of cur rent for starting than for continuous operation 1 3 SAFETY Before attempting to use the generator set care fully read the Safety Rules section of this manual Co...

Страница 8: ...such factors as fuel Btu content ambient temperature altitude engine condition etc Maximum power decreases about 3 5 for each 1 000 feet above sea level and will also decrease about 1 for each 6 C 10...

Страница 9: ...r com partment must be open and unobstructed for con tinued proper operation Without sufficient cooling and ventilating airflow the engine generator quickly overheats which causes it to shut down and...

Страница 10: ...NG THE ENGINE STABILIZE The generator supplies correct rated voltage only at the proper governed speed Some electrical appli ances may be extremely sensitive to voltage Incorrect voltages can damage s...

Страница 11: ...rength of its mag netic field is regulated and in turn the voltage deliv ered to connected electrical loads is controlled When the AC frequency is 60 Hertz voltage is regulated at 120 volts voltage to...

Страница 12: ...windings Salt as from sea air also will worsen the problem since it tends to absorb moisture from the air Salt and moisture when combined form a good electrical conductor 3 1 CHECKING THE ENGINE OIL...

Страница 13: ...l saturated with clean oil 6 Screw the new filter on by hand until its gasket lightly contacts the oil filter adapter Then tighten the filter an additional 3 4 to one turn 7 Remove the dipstick and wi...

Страница 14: ...area around the base of the spark plug to keep dirt and debris out of the engine Remove the spark plug and check the condition Replace the spark plug if worn or if reuse is question able 2 Clean spar...

Страница 15: ...eter NOTE Servicing of the battery is to be performed or supervised by personnel knowledgeable of batter ies and the required precautions Keep unauthor ized personnel away from batteries Damage will r...

Страница 16: ...e spark plug threaded openings Reinstall and tighten the spark plug 6 Remove the battery and store it in a cool dry room on a wooden board Never store the battery on any concrete or earthen floor 7 Cl...

Страница 17: ...alve clearance to make sure it did not change Figure 3 7 Figure 3 7 Tightening Jam Nut 3 13 RV GENERATOR SERVICE INTERVAL 50 Hours Clean Spark Arrestor 100 Hours Change Engine Oil filter 100 Hours Cle...

Страница 18: ...16 Section 4 Notes Recreational Vehicle Generator...

Страница 19: ...PART II INSTALLATION INSTRUCTIONS DANGER ONLY QUALIFIED ELECTRICIANS OR CONTRACTORS SHOULD ATTEMPT INSTALLATION...

Страница 20: ...his equipment is carried out by an Authorized Service Dealer The engine exhaust fumes contain carbon monox ide which can be DEADLY This dangerous gas if breathed in sufficient concentrations can cause...

Страница 21: ...If the victim is uncon scious apply first aid and get immediate medical help Never wear jewelry when working on this equip ment Jewelry can conduct electricity resulting in electric shock or may get c...

Страница 22: ...ds booklets latest revision are available from the sources indicated 1 NFPA Standard 501C Standard for Recreational Vehicles available from the National Fire Protection Association Batterymarch Park Q...

Страница 23: ...376 5 14 13 16 5 16 18 WELDNUTS 6 PLACES 82 5 3 1 4 343 4 13 1 2 423 2 16 11 16 717 7 28 1 4 50 8 2 118 4 5 8 223 5 8 13 16 60 2 3 8 210 8 1 4 176 6 6 15 16 83 5 3 5 16 429 5 16 15 16 414 5 16 5 16 3...

Страница 24: ...ator causing it to overheat 2 1 2 GENERATOR SUPPORT The generator must be securely attached to a metal framework that has been made part of the vehicle frame structure by bolting or welding The metal...

Страница 25: ...trength Figure 2 4 If constructing a compartment line the exterior underside of the compartment floor with 26 gauge galvanized steel Figure 2 4 Typical Compartment Construction All seams splices and j...

Страница 26: ...er may wish to consider the following Using special sound insulating materials Construction of a special noise abatement com partment NOTE Any method used to reduce noise must not adversely affect the...

Страница 27: ...25 Section 2 Installation Recreational Vehicle Generator Figure 2 7 Compartment Floor Cutout Drawing 0G3723 A...

Страница 28: ...re adequate cooling airflow is available to the unit before placing the unit into service If the unit shows signs of overheating enlarge the air openings Never place a unit into service until absolute...

Страница 29: ...tank outlet or in the supply line from the gas tank The following rules apply For best results the primary regulator supplies gaseous fuel to the secondary regulator at 11 inch es water column Do NOT...

Страница 30: ...e until the gas system has been properly tested for leaks To test the system a separate source of 12 volts DC is needed to open the gaseous fuel solenoid valve The leak test must comply fully with NFP...

Страница 31: ...F 65 C above the ambient air tempera ture Extend the exhaust system at least 1 inch 25 mm past the outer edge of the vehicle Do not terminate the exhaust system under the vehicle Terminate the exhaust...

Страница 32: ...a larger conductor size 2 6 3 GENERATOR AC CONNECTIONS Generator AC output leads BLACK hot and WHITE grounded neutral come out of the generator as shown in Figure 2 13 There is also a green lead that...

Страница 33: ...31 Section 2 Installation Recreational Vehicle Generator Figure 2 14 Transfer Switch Isolation Method Figure 2 15 Installation With Isolation Receptacle...

Страница 34: ...length and b prevailing ambient temperatures Generally the longer the cable and the colder the weather the larger the cable size must be as shown in the following chart For warm weather use No 2 cable...

Страница 35: ...and if nec essary fill to the dipstick FULL mark cross hatched area with the recommended oil Do not fill above the FULL mark 2 Check the fuel supply Gas fuel lines must have been properly purged and...

Страница 36: ...electrical loads equal to about 75 to 100 per cent of the unit s rated wattage amperage capacity Let the unit run at least 30 minutes with load applied During this part of the test check that the unit...

Страница 37: ...aust system is properly and safely installed ELECTRICAL CONNECTIONS Connections comply with local code requirements and all National Electrical Codes Junction box is properly installed Wiring meets al...

Страница 38: ...and add oil as needed down when the Start Stop 2 Defective low oil 2 Replace pressure switch switch is released pressure switch 3 Defective high temperature 3 Replace temperature switch switch 4 Defe...

Страница 39: ...37 Section 5 Notes Recreational Vehicle Generator...

Страница 40: ...3 3 6 5 4 6 5 4 1 2 1 2 PANEL REMOTE LOP 0 0 SP 0B START STOP SW1 IM SC 14 CH CS 0 0 0 FS FP SM HTO SWITCH HIGH TEMP OIL CLOSES ON HIGH TEMP L1 LIGHT RUN OPTIONAL LOP SWITCH LOW OIL PRESSURE SW2 SWITC...

Страница 41: ...A HTO SP1 85 13 14A 15 18 15 66 77 14 15 14 15 0 0 2 14 14A 14 F1 66 BCR 15 14 2A 13 17 4 15 2A 17 0 15 SW1 SW2 TC 0K 0 0 0 0B 17 18 GT 0 0I 4 2 0 11S 13 0K 4 22S 4 2A 6 2A REGULATOR VOLTAGE ELECTRONI...

Страница 42: ...40 Section 7 Exploded Views and Parts Lists Recreational Vehicle Generator Enclosure Drawing No 0F4589 B...

Страница 43: ...CARR 3 8 16 X 1 BRASS 28 0A4456 1 3 8 SPECIAL L WASHER 30 049813 2 NUT HEX M6 X 1 0 31 022237 1 WASHER LOCK 3 8 32 022131 2 WASHER FLAT 3 8 M10 33 0C5443 1 BLOCK TERMINAL BATTERY POST 34 0C7423 1 STUD...

Страница 44: ...42 Section 7 Exploded Views and Parts Lists Recreational Vehicle Generator Generator Drawing No 0F4590 C...

Страница 45: ...17 0D6832 1 BRACKET ENGINE MOUNTING 18 022145 18 WASHER FLAT 5 16 19 030231 3 SCREW HHC 5 16 18 X 1 1 2 20 0C3168 1 5 16 SPECIAL LOCK WASHER 21 022259 10 NUT HEX 5 16 18 22 0C8565 2 SCREW SHC M8 1 25...

Страница 46: ...44 Section 7 Exploded Views and Parts Lists Recreational Vehicle Generator Control Panel Drawing No 0F4591 A...

Страница 47: ...CIRCUIT BREAKER 15A 2 POLE 50HZ 14 0A1658 2 LOCK WASHER SPECIAL 15 075235 2 SCREW HHC M5 0 8 X 30MM 16 047411 2 SCREW HHC M6 1 0 X 16MM 17 049226 5 WASHER LOCK M5 18 051716 1 NUT HEX M5 0 8 19 075476...

Страница 48: ...46 Section 7 Exploded Views and Parts Lists Recreational Vehicle Generator GN 220 H SH Engine Drawing No 0F5791 G Part 1...

Страница 49: ...PTOR 26 0D7558 1 ADAPTOR CARB 27 078643 2 BOLT CARB MOUNT M6 1 0 x 75mm 28 0D8372 1 GASKET CARB TO AIRBOX 29 0C2756 1 ASSEMBLY GOVERNOR LEVER 30 0D7458 1 ROD GOVERNOR ITEM PART NO QTY DESCRIPTION 31 0...

Страница 50: ...48 Section 7 Exploded Views and Parts Lists Recreational Vehicle Generator GN 220 H SH Engine Drawing No 0F5791 G Part 2...

Страница 51: ...STEM SEAL 21 0A8822 1 CYLINDER HEAD GASKET 22 078691 1 OIL PRESSURE RELIEF COVER 23 0A5772 1 OIL PRESSURE SPRING 24 0A5776 1 11 32 BALL 25 074908 1 M5 FORM SCREW 26 078606 4 M6 1 0 x 12mm SCREW 27 076...

Страница 52: ...50 9 14 12 11 18 16 13 15 17 19 23 21 20 22 25 24 26 8 10 4 6 5 3 2 1 7 Section 7 Exploded Views and Parts Lists Recreational Vehicle Generator Regulator Drawing No 0F5819...

Страница 53: ...WASHER FLAT 3 2MM ID X 10MM OD 12 070728 2 SCREW PFILHM M3 0 5 X 5 13 0C5764 1 SPRING REGULATOR 14 0C4643A 1 INLET TWIN REG 11 11 DIA 15 0C5764 1 SEAL INLET REGULATOR 16 0C5968 1 SUPPORT INLET SEAL 1...

Страница 54: ...roper maintenance or unap proved modifications or the use of counterfeit and or grey market parts not made supplied or approved by Generac You are responsible for presenting your engine to a Generac A...

Страница 55: ...nty shall be warranted for the remainder of the ECS Warranty Period prior to the first scheduled replacement point for such emissions related part 4 Repair or replacement of any warranted emissions re...

Страница 56: ...y Policies and Procedures Guide THIS WARRANTY SHALL NOT APPLY TO THE FOLLOWING Generac Guardian generators that utilize non Generac replacement parts Costs of normal maintenance adjustments installati...

Отзывы: