Generac Portable Products 1675-0 Скачать руководство пользователя страница 7

7

Generac 2,400 PSI Pressure Washer

WARNING!

Never fill fuel tank completely full.

Provide space for fuel expansion. Wipe away any fuel
spillage from engine and equipment before starting.

Use fresh, clean unleaded automotive gasoline

and store in

approved, clean, covered containers. Use clean fill
funnels. Never use “stale” gasoline left over from last
season or gasoline stored for long periods.

• Clean area around fuel fill cap, remove cap.

• Slowly add gasoline to fuel tank. Use a funnel to prevent

spillage. Fill tank to “Fuel Level Mark”, as shown in
Figure 7.

• Install fuel cap and wipe up any spilled gasoline.

Connect Hose and Water Supply to

Pump

IMPORTANT: You must assemble the nozzle extension
and attach all hoses before you start the engine. Starting
engine without all hoses connected and water supplied will
damage the pump.

NOTE: Your pressure washer comes with a quick connect
that you can use to attach the high pressure hose to either
the pump or spray gun.

• Uncoil the high pressure hose and attach the female quick

connect to one end of the hose. Attach the male quick
connect to the high pressure fitting on the pump (Figure 8).

• Attach the high pressure hose to the high pressure outlet

on the pump (Figure 9). Pull down on the collar of the
quick connect, slide fitting into the pump and let go of
collar. Pull on hose to be sure of a tight connection.

NOTE: The quick connect is shown connecting the high
pressure hose to the pump. If you choose to use the quick
connect for the gun to hose connection, follow the same
directions to attach quick connect from gun to hose.

• Attach the other end of the hose to the base of the

spray gun (Figure 10). Tighten by hand.

• Before you connect your garden hose to the water inlet,

inspect the inlet screen (Figure 11). Clean the screen if it
contains debris, replace it if it is damaged. DO NOT
RUN THE PRESSURE WASHER IF THE SCREEN IS
DAMAGED. NEVER SIPHON INLET WATER.

• Run water through the garden hose for 30 seconds to

clean out any debris. Turn off water.

• Connect the garden hose to the water inlet. Tighten by

hand (Figure 11).

Connect high

pressure hose

here

Figure 10 — Connect High Pressure Hose to Spray Gun

Figure 9 — Connect High Pressure Hose to Pump

Figure 11 — Connect Garden Hose to Water Inlet

Inspect inlet

screen, Do

Not use if

damaged, clean

if dirty.

Figure 7 — Add Gasoline to Fuel Tank

Figure 8 — Attach Quick Connect

Содержание 1675-0

Страница 1: ...zards Obey all safety messages that follow this symbol to avoid possible injury or death Questions Help is just a moment away Call Generac Generator Helpline 1 800 270 1408 M F 8 5 CT Web www generac...

Страница 2: ...gasoline away from sparks open flames pilot lights heat and other ignition sources Do not light a cigarette or smoke WHEN OPERATING EQUIPMENT Do not tip engine or equipment at angle which causes gasol...

Страница 3: ...fall Use of pressure washer can create puddles and slippery surfaces WARNING Do not touch hot surfaces Allow equipment to cool before touching Running engines produce heat Temperature of muffler and...

Страница 4: ...tem prevents internal pump damage Chemical Injection Siphon Filter Use to siphon detergent or other pressure washer chemicals into the low pressure stream Choke Rod Prepares a cold engine for starting...

Страница 5: ...ic Knobs 2 J Hook Chemical Hose Clip Self Tapping Screws 5 If any of the above parts are missing or damaged call the pressure washer helpline at 1 800 270 1408 PREPARING PRESSURE WASHER FOR USE If you...

Страница 6: ...d from the left slot in the accessory tray Figure 4 Pinch the chemical hose and slide it into the metal clip as shown in Figure 5 Tilt the unit up by the handle and attach the metal clip to the rib on...

Страница 7: ...ect to the high pressure fitting on the pump Figure 8 Attach the high pressure hose to the high pressure outlet on the pump Figure 9 Pull down on the collar of the quick connect slide fitting into the...

Страница 8: ...sher To start your pressure washer for the first time follow these instructions step by step This starting information also applies if you have let the pressure washer sit idle for at least a day Plac...

Страница 9: ...igger How to Use Accessory Tray The unit is equipped with an accessory tray with places to store your nozzle extension and quick connect nozzles and slots to hold the cleaning solution bottle and the...

Страница 10: ...and release the collar Tug on the nozzle to make sure it is securely in place For most effective cleaning keep the spray nozzle between 8 to 24 inches away from the cleaning surface If you get the sp...

Страница 11: ...ss the trigger the recoil from the initial spray can be very strong The high pressure spray could cause you to fall if you are too close to the cleaning surface After you have applied detergent scour...

Страница 12: ...r abuse Inspect the hose each time before using it Check for cuts leaks abrasions or bulging of cover damage or movement of couplings If any of these conditions exist replace the hose immediately CAUT...

Страница 13: ...the engine according to instructions in To Start Your Pressure Washer Remove nozzle extension from spray gun Squeeze the trigger on the spray gun and hold When the water supply is steady and constant...

Страница 14: ...ode Flush for one to two minutes 2 Shut off the engine and let it cool then remove high pressure and garden hoses Disconnect spark plug wire from spark plug 3 Empty the pump of liquids by pulling the...

Страница 15: ...ng tube 3 See Check In Line Filter on page 12 4 Replace nozzle with high pressure nozzle Engine runs good at no load but bogs when load is added Engine speed is too slow Move throttle control to FAST...

Страница 16: ...16 Generac 2 400 PSI Pressure Washer EXPLODED VIEW UNIT...

Страница 17: ...rning Danger 15 190151GS 1 ASSEMBLY Complete Pump 16 187952GS 1 DECAL Cool Down 17 186301GS 1 KIT Nozzle 18 23139DGS 1 KEY 3 16 sq x 1 50 19 92479GS 4 LOCKWASHER M8 Ribbed 20 23707GS 4 SHCS 5 16 24 x...

Страница 18: ...18 Generac 2 400 PSI Pressure Washer EXPLODED VIEW PUMP...

Страница 19: ...TLE E 190591GS 0 KIT CHECK VALVES 24 3 O RING 12 x 2 25 3 O RING 12 42 x 1 78 26 6 ASSY Check Valve 27 3 O RING 15 x 2 44 4 SCREW M5 x 30 74 5 SCREW M6 x 35 Item Part Qty Description F 190592GS 0 KIT...

Страница 20: ...42 del C digo de Recursos P blicos de California Otros estados pueden tener leyes similares Las leyes federales se aplican en tierras federales Si equipa el silenciador con un apagachispas este deber...

Страница 21: ...o se enfr e antes de tocarlo Los motores al funcionar producen calor La temperatura del silenciador y de las reas cercanas puede alcanzar o pasar los 150 F 65 C Quemaduras severas pueden ocurrir al ha...

Страница 22: ...las de Rociado Inyecci n de qu micos 0 15 25 40 para diferentes alta presi n aplicaciones de limpieza Entrada de Agua Conexi n para la manguera de jard n Extensi n para Boquillas con Conexi n R pida L...

Страница 23: ...Auto Utiliza Enrosca 5 Si una de las partes que se mencionan arriba se encuentran da adas o hacen falta llame a la l nea directa del lavador a alta presi n al 1 800 270 1408 PREPARANDO EL LAVADOR A AL...

Страница 24: ...l asidero y conecte el clip de metal a la costilla en la cara inferior central de la bandeja accesoria Figura 27 Deslice la manga qu mica por el clip de metal para que no sea apretado pero kinked Agre...

Страница 25: ...ba Figura 29 De la misma manera conecte el otro extremo de la manguera a alta presi n a la salida de alta presi n de la bomba Figura 30 Hale el collar de la conexi n r pida desl celo apropiado en la b...

Страница 26: ...quina Lavadora a Presi n Para darle arranque a su m quina lavadora a presi n movida a motor por primera vez siga estas instrucciones paso a paso Esta informaci n acerca del arranque inicial tambi n s...

Страница 27: ...bservar una peque a cantidad de agua cuando elimine la presi n Utilizaci n de la Charola de Accesorios El unidad est equipado con una charola de accesorios Posee tres orificios para sostener la extens...

Страница 28: ...lar Hale la boquilla para asegurarse de que est conectada firmemente Para una limpieza m s efectiva mantenga la boquilla de rociado de 8 a 24 pulgadas de la superficie de limpieza Si coloca la boquill...

Страница 29: ...e Cuando oprima el gatillo la fuerza de reacci n del rociado inicial podr a hacerlo caer El rociado de la alta presi n podr a hacerlo caer si est muy cerca de la superficie que est limpiando Despu s d...

Страница 30: ...los acoplamientos Si existe cualquiera de estas condiciones remplace la manguera inmediatamente PRECAUCI N Nunca repare la manguera de alta presi n Remplacela con una manguera que cumpla con la capaci...

Страница 31: ...ausada por la presi n excesiva en la bomba La causa principal de la presi n excesiva en la bomba es cuando la boquilla se encuentra atascada o tapada con materiales extra os tales como tierra etc Para...

Страница 32: ...de los l quidos presentes en la bomba 4 El salvador de la bomba de la marca del uso Generac a previene la corrosi n construye y helado de bomba 5 Almacene la unidad en un lugar limpio y seco Proteger...

Страница 33: ...Lavadora de Presi n 2 400 PSI de Generac 33 NOTAS...

Страница 34: ...detergente 3 Vea Cheque En el Filtro de la L nea en la p gina 31 4 Use la boquilla de baja presi n negra El motor funciona bien cuando no tiene cargas pero funciona mal cuando se conecta una carga La...

Страница 35: ...ido autorizada o a cualquier tipo de alteraci n el mal uso negligencia accidentes sobrecarga velocidad excesiva mantenimiento inadecuado reparaci n o almacenamiento que seg n la opini n de los Product...

Страница 36: ...een subjected to improper or unauthorized installation or alteration misuse negligence accident overloading overspeeding improper maintenance repair or storage so as in Generac Portable Products judgm...

Отзывы: