background image

Bass Management 

Bass management divides the input audio 
signal into low frequency and high frequency 
content at the subwoofer crossover frequency. 
The signal content below the crossover 
frequency is reproduced by the subwoofer. 
The signal content above the crossover 
frequency is reproduced by the monitors. 

In the distributed bass management 

method used in the 7382A system, the 
monitors and the subwoofer receive full 
banwidth audio signal and the filtering is 
done separately inside each monitor and 
subwoofer. The lowpass and highpass 
filters are set in synchrony by the GLM 
management network. This method is only 
available in systems where GLM computer 
management is used and with monitors 
supporting this method. The subwoofer 
crossover frequency can be adjusted from 
50 Hz to 100 Hz. 

The distributed bass management 

supports three different signal cabling 
configurations:

•  All channels are routed through the 

subwoofer's IN/OUT connectors to the 
respective monitors.

•  Y-cables split each signal to the 

subwoofer's IN connector and the 
monitor's input.

•  Signal sources with dual outputs for each 

channel, one going to the subwoofer, the 
other going to the monitor.

Use With GLM Control 

Network

The 7382A SAM subwoofer is fully 
compatible with Genelec Loudspeaker 
Manager GLM software, the proprietary 
Genelec monitor management network, and 
all Genelec SAM monitors. 

Managing the 7382A SAM subwoofer 

using GLM software control unleashes 
the full power of room compensation in 
the 7382A SAM subwoofer, enabling 20 
parametric room compensation filters. This 
powerful room compensation functionality 
is only available when the GLM is used. 
Detailed information on the use with the 
GLM network is presented in the GLM 
System Operating Manual.

System Setup

The 7382A SAM subwoofer reaches its full 
potential when set up and calibrated using 
the GLM software. Genelec Loudspeaker 
Manager GLM and the proprietary Genelec 
monitor management network offer 

•  automated acoustic equalization 

individually for every monitor and 
subwoofer

•  automated level alignment 
•  distance (acoustic time-of-flight) 

calibration

•  aligning of the subwoofers for bass 

management 

for any reproduction system from stereo 

to complex 3D immersive setups, including 
one or more subwoofers. GLM setup is fast 
and accurate. It can precisely address the 
typical narrow-band low frequency modal 
resonances and radiation loads of a room 
and offers precise frequency response 
compensations. The settings can be 
controlled with a computer or the settings 
can be permanently stored in the monitors 
and subwoofers, to make the setup available 
at all times even when the computer is not in 
use. Genelec recommends setting up SAM 
monitoring systems using the GLM. You 
can find a detailed description of the setup 
process and the use of GLM in the GLM 
System Operating Manual.

The setup using GLM is fast and consists of 
the following steps:

•  Connect a CAT5 (RJ45) cable between 

each monitor (and subwoofer) and finally 
to the control network input of the GLM 
Adapter device (see Figure 1). 

•  Connect the GLM Adapter device to 

computer USB connector. 

•  Using a microphone stand, place the 

Genelec measurement microphone at the 
listening location with the microphone 
pointing upwards and the microphone 
top at the height of the engineer’s ear. 
The microphone is a part of the GLM 
User Kit.

•  Connect the GLM Adapter device to the 

computer USB port using cable included 
in the GLM User Kit.

•  Download the GLM software at the 

Genelec web site (www.genelec.com). 

•  Install the GLM software and follow the 

instructions in the software to measure 
and set up your system. 

•  If you plan to not use a computer for 

controlling the subwoofer, use the GLM 
software to write the setting into the 
subwoofer (use menu item “Store | Store 
the Current Group Settings…”).

With GLM software active and controlling 

the 7382A SAM subwoofer, the use of analog 

and digital inputs is controlled by the GLM 
software entirely. In the software ‘Input Type’ 
in the ‘Group’ definition sets this. The GLM 
software allows you to select and switch 
between the analog and digital audio inputs. 

If GLM control is not used, an AES/EBU 

digital audio signal will override analog 
signal. This means, if a valid digital audio 
clock is detected, the digital audio is 
selected over the analog audio. 

When the GLM acoustic settings have 

been stored in the 7382A SAM subwoofer 
and are active, the input is selected by the 
‘Group’ settings in the GLM software when 
the settings are stored.

RAM-SW Power Switch Light

When used without a connection to the GLM 
software, the light on the power switch on 
the RAM-SW is green, indicating normal 
operational mode. A red colour indicates 
amplifier clipping and yellow indicates 
thermal overload. If the red or yellow warning 
light appears, turn down the level. 

Additional Information

Positioning the Subwoofer in a Room

The location of the subwoofer can affect 
the frequency response and sound level 
dramatically particularly when the room 
acoustic effects are strong. Even small 
changes  in  a  subwoofer's  location  can 
make a marked difference in the frequency 
response. To begin, place the subwoofer 
near the front wall slightly offset from 
the room center line. Often systematic 
experimentation is needed to find the 
location giving the flattest frequency 
response at the listening location. Usually 
the subwoofer is placed close to a wall as 
this creates the highest output. Positioning 
the subwoofer close to a corner will boost 
the bass level at lower frequencies and may 
also cause asymmetrical spatial imaging. 
Measured from the subwoofer's driver the 
recommended distance to a wall is less than 
0.6 m (24 in). This avoids a loss of audio 
level at low frequencies created by the audio 
reflecting off the wall and cancelling certain 
frequencies radiated by the subwoofer. 

Operating Environment

This subwoofer is designed for indoor use 
only. The permissible ambient temperature 
is 15-35 degrees Celsius (50-95°F) 
and relative humidity 20 – 80% (non-
condensing). When the product has been 
stored or transported in a cool environment 
and is taken into a warm room, wait about 

Содержание SAM 7300 Series

Страница 1: ...Genelec 7382A Smart Active Subwoofer Operating Manual 7300 Series ...

Страница 2: ...ckage content Each subwoofer is supplied with an individually calibrated RAM SW amplifier unit If several 7382A subwoofers are used in the same system it is very important not to mix the subwoofer amplifier pairs A mains cable a 10 m 33 3 ft Speakon signal cable one 5 m GLM network cable and this operating manual are also included Operating Environment This subwoofer is designed for indoor use onl...

Страница 3: ... 50 60 Hz This enables the RAM SW amplifier to be plugged in anywhere globally When the mains power is provided with a generator inverter or certain lower quality UPS devices we recommend filtering power to remove harmonics and ensuring the voltage supply is stable Figure 1 Connector panel of the RAM SW amplifier unit Cable Gauge Max Length 4 x 2 0 mm2 14 AWG 30 m 100 ft 4 x 2 5 mm2 13 AWG 40 m 13...

Страница 4: ... and subwoofer and finally to the control network input of the GLM Adapter device see Figure 1 Connect the GLM Adapter device to computer USB connector Using a microphone stand place the Genelec measurement microphone at the listening location with the microphone pointing upwards and the microphone top at the height of the engineer s ear The microphone is a part of the GLM User Kit Connect the GLM...

Страница 5: ...measurements Digital Cabling Run a signal cable from the THRU AES EBU connector of the first subwoofer in the chain to the IN Digital connector of the next subwoofer Analog Cabling When daisy chaining multiple subwoofers with analog signals run cables from the OUT 1 and 2 connectors to the next subwoofer s IN 1 and 2 connectors The LFE channel has no output connector and can not be daisy chained M...

Страница 6: ...ce received including interference that may cause undesired operation Note This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and i...

Страница 7: ...emale balanced 10 kOhm Maximum analog input signal Analog input sensitivity 100 dB SPL at 1 m pin 1 gnd pin 2 non inverting pin 3 inverting 24 0 dBu 6 dBu Digital signal input connector XLR female 110 Ohm Digital signal output Thru connector XLR male 110 Ohm Digital audio input Word length Sample rate Digital input sensitivity 100 dB SPL at 1 m Positive input gain selection GLM control AES EBU Sin...

Страница 8: ...ontact Genelec Inc 7 Tech Circle Natick MA 01760 USA Phone 1 508 652 0900 Fax 1 508 652 0909 Email genelec usa genelec com In China please contact Beijing Genelec Audio Co Ltd Room 101 1st Floor Building 71 B33 Universal Business Park No 10 Jiuxianqiao Road Chaoyang District Beijing 100015 China Phone 86 10 5823 2014 Post code 100015 Email genelec china genelec com In Sweden please contact Genelec...

Отзывы: