Figure 13. Frequency responses at 0, 15, 30, 45 and 60  

degree horizontal angles and power response in full space. 

Input level -20 dBu.

Figure 12. The curves above show the effect of the “Bass 

Tilt”, “Treble Tilt”, “Desktop Low Frequency” and “Bass 

Roll-Off” controls on the free field response of the S360A. 

enables easy integration with the 7300 series subwoofers and 

precise room acoustic compensations. For more detailed system 

configuration and matching products, please consult the on-line 

Genelec Product Selection Tool, Monitor Setup Guide booklet 

and Immersive Solutions brochure at www.genelec.com.

Maintenance

There are no user serviceable parts inside the monitor. Maintenance 

or repair must only be done by a Genelec certified service. 

Accessories

Up to date information about Genelec accessories can be found 

in the Accessories Catalogue which is available on Genelec’s 

website www.genelec.com.

Safety Considerations and warnings

The S360A has been designed in accordance with international 

safety standards. To ensure safe operation and to maintain the 

monitor under safe operating conditions, the following warnings 

and precautions must be observed:

•  Servicing and adjustment must only be performed by a 

certified Genelec service. No part of the monitor enclosure 

may be opened.

•  Do not use this product with a mains outlet or mains power 

cord without the protective earth contact as this may lead to 

personal  injury.

•  To prevent fire or electric shock, do not expose the unit to 

water or moisture. 

•  Do not place any objects filled with liquid, such as vases, on 

the monitor or near it. 

•  Note that the amplifier is not completely disconnected from 

the mains power unless the mains power cord is removed 

from the amplifier or the mains outlet.

•  Free flow of air behind the monitor is necessary to maintain 

sufficient cooling. Do not obstruct airflow around the 

monitors.

These monitors are capable of producing sound pressure levels 

Product Data and Measurements

way in excess of 85 dB SPL and to cause instant, permanent 

hearing damage. Please do not stand close without hearing 

protection when the unit is powered.

Guarantee

Genelec S360A is guaranteed for two years against 

manufacturing faults or defects altering performance. Refer to 

the reseller for full sales and guarantee terms.

Compliance to FCC Rules

Note: This equipment has been tested and found to comply 

with the limits for a Class B digital device, pursuant to part 

15 of the FCC Rules. These limits are designed to provide 

reasonable protection against harmful interference in a 

residential installation. This equipment generates, uses and 

can radiate radio frequency energy and, if not installed and 

used in accordance with the instructions, may cause harmful 

interference to radio communications. 

However, there is no guarantee that interference will not occur 

in a particular installation. If this equipment does cause harmful 

interference to radio or television reception, which can be 

determined by turning the equipment off and on, the user is 

encouraged to try to correct the interference by one or more of 

the following measures: 

•  Reorient or relocate the receiving antenna. 

•  Increase the separation between the equipment and 

receiver. 

•  Connect the equipment into an outlet on a circuit different 

from that to which the receiver is connected. 

•  Consult the dealer or an experienced radio/TV technician for 

help. 

Modifications not expressly approved by the manufacturer 

could void the user’s authority to operate the equipment under 

FCC rules.

80

85

90

dB

SPL

20

20k

50

100

200

500

1k

2k

5k

10k

Frequency Hz

Genelec Oy S360

29 Oct 18

80

85

90

BASS ROLL-OFF

TREBLE TILT

BASS TILT

80

85

90

DESKTOP

20

20k

50

100

200

500

1k

2k

5k

10k

Frequency Hz

Genelec Oy S360

26 Oct 18

60°

15°

30°

45°

85

90

95

100

70

75

80

85

90

95

dB

SPL

dB

SWL

Содержание S360A

Страница 1: ...S360A Smart Active Monitor Operating Manual ...

Страница 2: ...manual The S360A provides two pairs of enclosure mounting points and its integrated system electronics can be placed remotely using the 2U high rack installation kit Versatile mounting is further supported by downward firing flow optimised laminar integrated reflex ports LIPTM also making it suitable for use in conjunction with perforated screens To focus low frequency output while preventing vibr...

Страница 3: ...ls on the back panel of a S360A Figure 1 GLM control network cabling Figure 3 Connector panel detail MICROPHONE PLACED IN THE LISTENING POSITION 292 0063 GLM TERMINATOR COMPUTER RUNNING GLM SOFTWARE USB CABLE GLM ADAPTER GLM NETWORK CABLE MONITORS ANALOG IN DIGITAL THRU AES EBU DIGITAL IN AES EBU GLM NETWORK MAINS INPUT 50 60 Hz 200 W 100 240 V WARNING ELECTRIC SHOCK HAZARD DO NOT OPEN DO NOT SUBJ...

Страница 4: ...The AES EBU input supports two channels in a single cable When the digital source controls the level it may be advantageous to lower the level setting in the monitor s controls which will enable a higher digital level and improved use of the digital resolution The digital input level is referenced to 0 dBFS dB relative to the digital full scale the largest level that can be represented in the AES ...

Страница 5: ...ring The S360A supports monitoring of the internal temperature input levels and levels to the transducers input clip and digital audio full scale warning and activation of the system overload protection These can be monitored using the GLM Loudspeaker Manager software for all monitors in the monitor group Energy saving Energy saving Intelligent Signal Sensing ISS can put the monitor automatically ...

Страница 6: ...e Figure 8 S360A Iso Plate vibration decoupling platform and the dual downward firing bass reflex ports Figure 9 Ceiling mount 8000 436 used with S360 424B bracket Note the use of different mounting points on the bracket for different tilt angles Figure 7 The S360 450B side side bracket shown with wire suspen sion a truss mount clamp and S360 465B ceiling mount plate Mounting point 2 Mounting poin...

Страница 7: ...structions for the S360A mounting brackets to attach them to the enclosure Flush mounting The unique Iso Plate vibration decoupling platform enables in wall flush mounting There are two main methods for in wall installation In method one the amplifier remains on the enclosure when the monitor is inserted into the recess There must be sufficient ventilation in the recess space behind of the enclosu...

Страница 8: ...ntain sufficient cooling Do not obstruct airflow around the monitors These monitors are capable of producing sound pressure levels Product Data and Measurements way in excess of 85 dB SPL and to cause instant permanent hearing damage Please do not stand close without hearing protection when the unit is powered Guarantee Genelec S360A is guaranteed for two years against manufacturing faults or defe...

Страница 9: ... the S360A as a function of frequency Figure 14 The curves above show the horizontal directivity characteristics of the S360A Figure 18 The maximum short term SPL of the S360A as a function of distance and the monitoring room reverberation time RT60 Figure 17 The curve above shows the phase response of the S360A as a function of frequency ...

Страница 10: ... information 292 S360AT 6 MADE IN FINLAND S360A SERIAL NUMBER www genelec com RESET TO FACTORY SETTINGS PUSH BUTTON FOR 10 SEC SENSITIVITY IN dBu FOR 100 dB SPL 1 m 2 4 2 4 6 6 dBu 0 20 160 2 2 4 dB 6 0 4k 20k BASS TILT 800 BASS ROLL OFF DESKTOP ALL OFF TREBLE TILT Frequency Hz dB dB ON OFF BASS ROLL OFF BASS TILT 2 2 TREBLE TILT 2 DESKTOP 160 Hz 4 LED DISABLE A 20 dB B STORED 10 dB LEVEL DIGITAL ...

Страница 11: ...ager GLMTM software AMPLIFIER SECTION SIGNAL PROCESSING SECTION S360A Bass amplifier short term output power Treble amplifier short term output power Long term output power is limited by driver protection circuitry 250 W 100 W Amplifier system THD at nominal output 0 01 Mains voltage 100 240 VAC 50 60 Hz Power consumption ISS active Idle Full output short term 1 W 11 W 230 W S360A Analog signal in...

Страница 12: ...Genelec Inc 7 Tech Circle Natick MA 01760 USA Phone 1 508 652 0900 Fax 1 508 652 0909 Email genelec usa genelec com In China please contact Beijing Genelec Audio Co Ltd B33 101 Universal Business Park No 10 Jiuxianqiao Road Chaoyang District 100015 Beijing China Phone 86 10 5823 2014 400 700 1978 Email genelec china genelec com In Sweden please contact Genelec Sverige Ellipsvägen 10B P O Box 2306 ...

Отзывы: