7
any packing or before connecting to mains power. Sufficient
cooling must be ensured. Behind, above and on both sides
of the S360A monitor the minimum clearance is 50 mm (2
in). This space must be ventilated sufficiently to dissipate the
heat.
Mounting and Placing Monitors
Mounting
The S360A has mounting points on the top and bottom and on
the left and right sides. S360-424B top-bottom and S360-450B
side-side mount brackets are available for the S360A. These are
used with standard Genelec mounting accessories, offering floor
stands, wall mounts, ceiling mounts and truss mounts. All mounting
points on the enclosure have M10 (10 mm diameter, metric thread)
threads. Correct bolts are included with the mounting brackets.
The brackets have several hole pairs to allow finding the correct
orientation and load balance. The S360A can be turned to point
in the correct direction before the bracket bolts are tightened.
The tightening torque for the attachment bolts is 10 - 20 Nm
(7.4 -14.8 lb ft).
The S360-424B top-bottom mount bracket is used with the
S360-444B wall mount and ceiling mount plate S360-465B.
The S360-450B side-side mount bracket is used with the S360-
415B floor stand and ceiling/truss mounts.
The Iso-Plate™ is detached before the mounting brackets
are used. To do this, remove carefully the four rubber covers
on the botton of the Iso-Plate feet. This shows the mounting
screws. Use an M6 Allen key to remove the screws and lift
off the Iso-Plate. Remove the four vibration dampers bt
turning them anti-clockwise. Store the Iso-Plate and other
components for later use. Follow the mounting instructions for
the S360A mounting brackets to attach them to the enclosure.
Flush mounting
The unique Iso-Plate vibration decoupling platform enables in-
wall (flush) mounting. There are two main methods for in-wall
installation.
In method one, the amplifier remains on the enclosure when
the monitor is inserted into the recess. There must be sufficient
ventilation in the recess space behind of the enclosure to control
the temperature of the amplifier. The temperature of the adjacent
air must not exceed 35 degrees Celsius (95°F.)
In method two, the amplifier is detached from the enclosure and
placed into the 9032A rack mount kit. Then standard Speakon
and RJ-45 cables connect the amplifier rack installation kit to
the enclosure. The rack mount accessory takes 2U vertical
space in the 19 in rack. Sufficient air flow must be ensured to
avoid premature limiting of the output level. ELECTRIC SHOCK
HAZARD! To ensure electric safety, the removal of the amplifier
from the enclosure and its installation to the rack mount chassis
may only be done by qualified Genelec service personnel.
Use with Subwoofers
Genelec recommends using the 7300 series subwoofers,
particularly models 7380 and 7382 are a good match with
the S360A. The S360A contains a subwoofer crossover
highpass filter, which can be set between 50 and 100 Hz in 5
Hz increments. This selection is done in the GLM software and
Figure 11. The S360-424B top-bottom mount bracket for
S360A can be attached to the S360-444B wall mount at
different mounting points.
Figure 12. Left: S360-450B side-side mount bracket used
with S360-415B floor stand. Note the removed Iso-Plate.
Right: The S360-408B stand plate used with the floor
stand, in which case the Iso-Plate remains attached.
Figure 10. The S360A amplifier installed in the 9032A rack
mount kit.