Genelec 8350A Скачать руководство пользователя страница 3

3

These monitors produce 100 dB SPL sound level at 1 meter in 

free space for a digital input signal of –30 dBFS. The DIGITAL 

OUT male XLR carries an unaltered copy of the digital signal fed 

into the digital in connector. This enables daisy-chaining up to 

four monitors. 

The CONTROL NETWORK RJ-45 connectors are used with 

Genelec Loudspeaker Manager™ (GLM™) network. These 

connectors are not Ethernet LAN compatible. Do not connect 

to Ethernet LAN.

Stand-Alone Control Functions

Bass Roll-Off Control

Bass Roll-Off control attenuates the monitor’s output near the 

cut-off frequency. Attenuation levels of -2 dB, -4 dB or -6 dB 

(both switches ON) can be selected.

Desktop 160 Hz

The desktop low frequency control (switch 5) attenuates the 

bass frequencies around 160 Hz by 4 dB. This feature is de-

signed to compensate for the boost often occurring at this fre-

quency range when the monitor is placed upon a meter bridge, 

table or similar reflective surface. 

Bass Tilt Control

The Bass Tilt control switches (swiches 3 and 4) offer three at-

tenuation levels for the bass response below 800 Hz, usually 

necessary when the monitors are placed near room boundaries. 

The attenuation levels are -2 dB, -4 dB and -6 dB.

Treble Tilt Control

Treble Tilt control allows adjusting the treble response above 5 

kHz by +2 dB, -2 dB or -4 dB, which can be used for correcting 

an excessively bright or dull sounding system or to compensate 

for high frequency level loss if the monitor is placed behind a 

screen. 

LED Disable

This switch shuts off the front panel LED light.

ISS

This switch activates or deactivates the ISS automatic power 

saving function. The default time for ISS activation is 60 

minutes, but can be adjusted in GLM.

Digital

The Digital switch selects the digital audio channels on the 

AES/EBU. Turning both switches on reproduces the sum of the 

A and B channels. A 6 dB of attenuation is applied to avoid 

overloading the monitor. If the AES/EBU cable is operated in 

dual-wire mode, the monitor detects this automatically and the 

channel selection switches have no effect.

Level

The Level switches scale down the monitor output level in 10 dB 

steps. The effects of these switches add up and combine with 

the effect of the rotary level adjustment control. The combined 

total setting range is 42 dB.

Stored

Stored switch selects the use of the controls on the monitor’s 

back panel or the settings stored inside the monitor memory 

using the GLM system calibration software. Setting the Stored 

switch to OFF position selects the settings defined by the 

monitor’s own controls. Setting the Stored switch to ON position 

selects the use of internally stored GLM settings. Using the 

Figure 2. Connectors and controls on the back panel of a 8350A. 8340A shares the same layout.

ANALOG

IN

DIGITAL THRU

AES/EBU

DIGITAL IN

AES/EBU

MADE IN FINLAND

8350A

MAGNETICALLY SHIELDED

SERIAL NUMBER

www.genelec.com

GLM

NETWORK

MAINS INPUT

50 / 60 Hz 200 W

100 - 240 V~

29

2-

83

50

T-

6

This device complies

with FCC Part 15 and

Canadian ICES-003

radio frequency

Class B emission

requirements. Refer

to operating manual

for full information.

BA

SS

RO

LL

-OFF

LE

DD

IS

AB

LE

BA

SS

TI

LT

A

-2

0d

B

B

-2

-4

-2

-4

ON

OFF

ST

OR

ED

(d

B)

-1

0d

B

RESET TO FACTORY

SETTINGS: PUSH

BUTTON FOR 10 SEC

LE

VE

L

DIGI

TA

L

TR

EB

LE

TI

LT

+2

-4

DE

SK

TO

P1

60

Hz

-4

(d

B)

20

160

+2

-2
-4

dB

-6

0

4k

20k

BASS

TILT

800

BASS

ROLL-OFF

DESKTOP

ALL OFF

TREBLE

TILT

Frequency (Hz)

INPUT dBu

PRODUCING

100 dB SPL (1 m)

IS

S

-2

+4

+2

-4

-6

+6

dBu

0

ON

OFF

SMART ACTIVE MONITOR

DIP SWITCHES FOR

STAND-ALONE USE

ROTARY LEVEL

CONTROL

POWER

SWITCH

AUDIO SIGNAL

CONNECTORS:

-DIGITAL IN

-DIGITAL THRU

-ANALOG IN

MAINS INPUT

GLM NETWORK

CONNECTORS

Monitor  

Mounting Position

Treble 

Tilt

Bass 

Tilt

Bass 

Roll-Off

Desktop

Flat anechoic 

response

None

None

None

None

Free standing in 

a damped room

None

-2 dB

None

None

Free standing in 

a reverberant room

None

-4 dB

None

None

Near field on 

a reflective surface

None

-2 dB

None

-4 dB

In a corner

None

-4 dB

-4 dB

None

Table 1. Suggested Tone Control settings for some typical moni-

tor placement positions.

Содержание 8350A

Страница 1: ...8350A 8340A Operating Manual 750 8340A 8350A ...

Страница 2: ... RJ45 cable between each monitor and subwoofer and finally to the control network input of the GLM Adapter device see Figure 1 Connect the GLM Adapter device to computer USB connector Using a microphone stand place the Genelec measurement microphone at the listening location with the microphone pointing upwards and the microphone top at the height of the engineer s ear The microphone is a part of ...

Страница 3: ...nitor If the AES EBU cable is operated in dual wire mode the monitor detects this automatically and the channel selection switches have no effect Level The Level switches scale down the monitor output level in 10 dB steps The effects of these switches add up and combine with the effect of the rotary level adjustment control The combined total setting range is 42 dB Stored Stored switch selects the...

Страница 4: ...onitor so that its acoustic axis point towards the listening position see Figure 3 Vertical orientationispreferable asthiseliminatesacousticalcancellation problems around the crossover frequency Place the monitors symmetrically at equal distances from the listening position If possible place the listening position on the left right centerline of the room see Figure 4 When a monitor far away 1 to 2...

Страница 5: ...e user s authority to operate the equipment under FCC rules Table 2 Monitor front panel light indications summary Colour Indication Solid greed Normal state normal operation Blinking green GLM is adjusting the monitor Green blink every 10 sec Monitor is an ISS power saving sleep state Red blink Power amplifier overload protection is active audio is modified because of protection Solid red Monitor ...

Страница 6: ...eristics of the 8350A measured at 1 m The lower curve shows the system s power response 20 20k 50 100 200 500 1k 2k 5k 10k Hz Genelec Oy 8340 horizontal off axis response level dBr vs freq Hz 10 Mar 16 0 60 15 30 45 50 100 55 60 65 70 75 80 85 90 95 d B r A 20 20k 50 100 200 500 1k 2k 5k 10k Hz Genelec Oy 8350A 31 March 2016 80 85 90 d B r A BASS ROLL OFF TREBLE TILT 80 85 90 80 85 90 DESKTOP LF B...

Страница 7: ...from 100 Hz to 3 kHz at 1 m 110 dB SPL 112 dB SPL Maximum long term RMS acoustic output in the same conditions with IEC weighted noise limited by driver protection circuit at 1 m 100 dB SPL 103 dB SPL Maximum peak acoustic output per pair in a listening room with music material at 1 m 118 dB 121 dB Self generated noise level in free space at 1 m on axis A weighted 5 dB Harmonic distortion at 90 dB...

Страница 8: ...m output power Long term output power is limited by driver protection circuitry 150 W 150 W 150 W 200 W Amplifier system THD at nominal output 0 01 System Signal to Noise ratio A weighted Bass Treble 109 dB 110 dB 109 dB 112 dB Mains voltage 100 240 VAC 50 60 Hz Power consumption ISS active Idle Full output short term 1 W 12 W 180 W 1 W 12 W 230 W 8340A 8350A Analog signal input connector XLR fema...