Genelec 8350A Скачать руководство пользователя страница 2

2

Introduction

Congratulations and a thank you for the purchase of this Genelec 

Smart Active Monitor (SAM) system. This manual addresses 

the stand-alone setup and use of the 8340A and 8350A SAM 

monitors. These monitors can also be set up and used with 

the Genelec Loudspeaker Manager GLM™ and the proprietary 

Genelec monitor control network and software, offering much 

more versatile acoustic settings and features. Use with the 

GLM™ is described in the GLM™ System Operating Manual.

All Genelec SAM systems are designed to integrate easily 

into all professional environments, supporting both standard 

analog line level audio and AES/EBU formatted digital audio 

signals. 

The 8340A and 8350A are suitable for professional monitoring 

tasks demanding high precision and reliability of monitoring. 

The Minimum Diffraction Enclosure™ (MDE™) and advanced 

Directivity Control Waveguide™ (DCW™) technologies 

provide excellent frequency balance even in difficult acoustic 

environments.

Each monitor is supplied with a mains cable, one 5 m GLM 

network cable and an operating manual.

Energy saving Intelligent Signal Sensing (ISS™) can be turned 

on to put the monitor automatically into a deep sleep state 

where the product consumes less than one Watt of power. 

Upon sensing an input signal the monitor automatically wakes 

up to full operation. The wait until entering the ISS power save 

can be configured using the GLM software. When the ISS is 

active you can have your monitoring system ready for action 

at all times. 

System setup using GLM™ Control 

Network

Although the 8340A and 8350A can be used without the 

GLM™ software and control network, they only reach their 

full potential when set up and calibrated using the GLM™ 

software. Genelec Loudspeaker Manager GLM™ and the 

proprietary Genelec monitor control network and software 

offer automated acoustic equalization and alignment for any 

reproduction system from simple stereo to very complex 

3D immersive audio setups including also one or more 

subwoofers. GLM setup is fast and accurate. The settings can 

be controlled with a computer or be permanently stored in the 

monitors to make the setup available at all times even when 

a computer is not in use. Genelec recommends setting up 

SAM monitoring systems using GLM. You can find a detailed 

description of the setup and the use of GLM™ in the GLM™ 

System Operating Manual.

The setup is fast and consists of the following steps:

•  Connect a CAT5 (RJ45) cable between each monitor (and 

subwoofer) and finally to the control network input of the 

GLM Adapter device (see Figure 1). 

•  Connect the GLM Adapter device to computer USB 

connector. 

•  Using a microphone stand, place the Genelec measurement 

microphone at the listening location with the microphone 

pointing upwards and the microphone top at the height of the 

engineer’s ear. The microphone is a part of the GLM User Kit.

•  Connect the microphone cable to the microphone input in 

the GLM Adapter device.

•  Download the GLM software at the Genelec web site (www.

genelec.com). 

•  Install the GLM software and follow the instructions in the 

software to measure and set up your monitors. 

•  If you plan to not use a computer for controlling the 

monitors, use the GLM software to write the setting into the 

monitors (use menu item “Store | Store the Current Group 

Settings…”). 

While the GLM network is disconnected the settings stored 

using the Genelec Loudspeaker Manager software can be 

selected in use by setting the STORED switch ON.  

Setup without using the GLM

When GLM is not available, you can use the settings on the 

monitor for system setup. These settings are limited but provide 

the basic acoustical calibrations and input selection. To use this 

method, set the STORED switch OFF.  

Connect the MAINS INPUT to the mains supply. These 

products support any mains voltage globally (100-240 VAC, 

50-60 Hz) so they can be plugged in anywhere. If the mains 

power is provided with a generator, inverter or certain lower-

quality UPS devices, we recommend filtering of the mains 

power voltage harmonics and taking care that the voltage 

supply is stable.

The ANALOG IN connector is used for analog audio signals. The 

maximum input level is +25 dBu. These monitors produce 100 

dB SPL sound level at 1 meter in free space for an analogue 

input signal of -6 dBu. 

The DIGITAL IN AES/EBU female XLR connector is for AES/

EBU formatted digital audio input signals. This input is selected 

automatically when a valid digital audio signal is present. 

Analog input is selected when the AES/EBU signal input is 

disconnected. The AES/EBU input supports two channels in a 

single cable). When the digital source device controls the digital 

output level, it may be advantageous to lower the level on the 

monitor’s controls, which will enable the use of a higher digital 

signal level with more digital resolution. With digital inputs the 

audio is referenced to 0 dBFS (dB relative to the digital full scale, 

the largest level that can be represented in the AES/EBU signal). 

LISTENING

POSITION

MICROPHONE

GLM

NETWORK

GLM

NETWORK

GLM

NETWORK

USB

Figure 1. GLM control network cabling

Содержание 8350A

Страница 1: ...8350A 8340A Operating Manual 750 8340A 8350A ...

Страница 2: ... RJ45 cable between each monitor and subwoofer and finally to the control network input of the GLM Adapter device see Figure 1 Connect the GLM Adapter device to computer USB connector Using a microphone stand place the Genelec measurement microphone at the listening location with the microphone pointing upwards and the microphone top at the height of the engineer s ear The microphone is a part of ...

Страница 3: ...nitor If the AES EBU cable is operated in dual wire mode the monitor detects this automatically and the channel selection switches have no effect Level The Level switches scale down the monitor output level in 10 dB steps The effects of these switches add up and combine with the effect of the rotary level adjustment control The combined total setting range is 42 dB Stored Stored switch selects the...

Страница 4: ...onitor so that its acoustic axis point towards the listening position see Figure 3 Vertical orientationispreferable asthiseliminatesacousticalcancellation problems around the crossover frequency Place the monitors symmetrically at equal distances from the listening position If possible place the listening position on the left right centerline of the room see Figure 4 When a monitor far away 1 to 2...

Страница 5: ...e user s authority to operate the equipment under FCC rules Table 2 Monitor front panel light indications summary Colour Indication Solid greed Normal state normal operation Blinking green GLM is adjusting the monitor Green blink every 10 sec Monitor is an ISS power saving sleep state Red blink Power amplifier overload protection is active audio is modified because of protection Solid red Monitor ...

Страница 6: ...eristics of the 8350A measured at 1 m The lower curve shows the system s power response 20 20k 50 100 200 500 1k 2k 5k 10k Hz Genelec Oy 8340 horizontal off axis response level dBr vs freq Hz 10 Mar 16 0 60 15 30 45 50 100 55 60 65 70 75 80 85 90 95 d B r A 20 20k 50 100 200 500 1k 2k 5k 10k Hz Genelec Oy 8350A 31 March 2016 80 85 90 d B r A BASS ROLL OFF TREBLE TILT 80 85 90 80 85 90 DESKTOP LF B...

Страница 7: ...from 100 Hz to 3 kHz at 1 m 110 dB SPL 112 dB SPL Maximum long term RMS acoustic output in the same conditions with IEC weighted noise limited by driver protection circuit at 1 m 100 dB SPL 103 dB SPL Maximum peak acoustic output per pair in a listening room with music material at 1 m 118 dB 121 dB Self generated noise level in free space at 1 m on axis A weighted 5 dB Harmonic distortion at 90 dB...

Страница 8: ...m output power Long term output power is limited by driver protection circuitry 150 W 150 W 150 W 200 W Amplifier system THD at nominal output 0 01 System Signal to Noise ratio A weighted Bass Treble 109 dB 110 dB 109 dB 112 dB Mains voltage 100 240 VAC 50 60 Hz Power consumption ISS active Idle Full output short term 1 W 12 W 180 W 1 W 12 W 230 W 8340A 8350A Analog signal input connector XLR fema...

Отзывы: