background image

Genelec 7360A and 7370A Smart Active Subwoofers

Introduction

Congratulations and a thank-you for the 
purchase of this Genelec 7300 series 
subwoofer. This manual addresses setting 
up and using the Genelec 7360A and 7370A 
subwoofers. These subwoofers are designed 
to integrate easily into all environments, both 
those using analog audio as well as those 
using digital AES/EBU audio. Genelec 7360A 
and 7370A subwoofers are designed for 
precise monitoring of multichannel analog 
audio signals and stereo AES/EBU signals. 
Multichannel AES/EBU signal can be 
monitored by using the 9301 multichannel 
digital audio interface device connected to 
the subwoofer. 

Energy saving Intelligent Signal Sensing 

(ISS) can be turned on to put the subwoofer 
automatically into a standby state when 
audio signal has been absent for a selected 
time. In the standby mode the product 
consumes less than one Watt of power. 
Upon sensing an input signal the subwoofer 
automatically wakes up to full operation. 
The wait until entering the ISS power save 
can be configured using the GLM software. 
When the ISS is active you can have your 
monitoring system ready for action at all 
times. 

Installation

Each subwoofer is supplied with a mains 
cable, one 5 m GLM network cable, mains 
cable, and an operating manual. Before 
connecting switch the subwoofer and 
monitors off. 

Connections

Seven balanced XLR input/output pairs 
are available for analog signals (see Figure 
1). There is a dedicated LFE In and LFE 
Out
. The Link In and Link Out connectors 
can be used to for daisy-chaining multiple 
subwoofers with minimum cable count. In 
addition to these analog signal connectors, 
digital audio in and out connectors 
supporting AES/EBU format are available. 
The digital out connector can be used to 
daisy chain multiple subwoofers while digital 
audio is being used. 

Multichannel AES/EBU signal can be 

monitored by using the 9301 multichannel 

digital audio interface device connected to 
the subwoofer. 

Two CAT5 (RJ45) GLM Network 

connectors are available for computer 
control  using  the  Genelec  Loudspeaker 
Manager (GLM) software. 

Bypass connector supports a ¼ in 

jack switch-operated subwoofer bass 
management bypass function when the fixed 
85 Hz subwoofer crossover is used. 

The mains input supports a wide mains 

voltage range (100-240 VAC, 50-60 Hz) 
and enables the subwoofer to be plugged 
in anywhere globally. If the mains power is 
provided with a generator, inverter or certain 
lower-quality UPS devices, we recommend 
filtering of the mains power voltage 
harmonics and taking care that the voltage 
supply is stable.

Bass Management 

Bass management splits the signal from 
each input into low and high frequency 
components. Signal content below the 
crossover frequency is reproduced by the 
subwoofer and signal content above the 
crossover frequency is reproduced by the 
monitors connected to the outputs of the 
subwoofer. 

The 7360A and 7370A offer two bass  

management methods:

Centralized bass management 

This method builds both the highpass and 
the lowpass filters in the subwoofer and can 
be used in all setups, with or without GLM 
control. A fixed 85 Hz crossover filter for the 
analog main channels is default for manual 
use.

In this method all analog signal cables 

are routed through the subwoofer's IN/
OUT connectors to the respective main 
monitors.

Distributed bass management 

In this method the lowpass filter is applied 
in the subwoofer and the highpass filter in 
the monitor, and these are set in synchrony 
using the GLM control network. This method 
is only available in systems where GLM is 
used.

The GLM software enables adjusting the 

subwoofer/monitor crossover from 50 Hz to 

100 Hz when distributed bass management 
is used. 

The distributed bass management 

supports three different signal cabling 
configurations:

•  All channels routed through the 

subwoofer's IN/OUT connectors to the 
respective monitors.

•  Y-cables from the source to the 

subwoofer's IN connector and the 
monitor's signal input.

•  Signal sources with dual outputs for each 

channel.

Using With GLM™  

Control Network

Subwoofers are fully compatible with 
Genelec Loudspeaker Manager GLM™ and 
the proprietary Genelec monitor control 
network and Genelec SAM monitors. Using 
the GLM control method unleashes the full 
room compensation power in the subwoofer, 
with 20 parametric room compensation 
filters. This level of room compensation detail 
is only available when the GLM is used. Use 
with the GLM™ network is described in the 
DSP System Operating Manual.

System setup 

Although the subwoofer can be used without 
the GLM™ software and control network, 
they only reach their full potential when 
set  up  and  calibrated  using  the  GLM™ 
software.  Genelec  Loudspeaker  Manager 
GLM™  and  the  proprietary  Genelec 
monitor control network offer automated 
acoustic equalization and alignment for any 
reproduction system from simple stereo to 
very complex 3D immersive setups including 
also one or more subwoofers. GLM setup is 
fast and accurate and can precisely address 
the typical narrow-band low frequency mode 
resonances of a room. The settings can be 
controlled with a computer or be permanently 
stored in the monitors to make the setup 
available at all times even when a computer 
is not in use. Genelec recommends setting 
up SAM monitoring systems using GLM. You 
can find a detailed description of the setup 
and the use of GLM™ in the GLM™ System 
Operating Manual.

Содержание 7360A

Страница 1: ...Genelec 7360A and 7370A Smart Active Subwoofers Operating Manual 7300 Series 750 7360A 7370A ...

Страница 2: ...Bass management splits the signal from each input into low and high frequency components Signal content below the crossover frequency is reproduced by the subwoofer and signal content above the crossover frequency is reproduced by the monitors connected to the outputs of the subwoofer The 7360A and 7370A offer two bass management methods Centralized bass management This method builds both the high...

Страница 3: ...er When using this method run each signal cable first to the subwoofer Then run the respective output to the monitor This monitor feed signal is highpass filtered at 85 Hz When using the LFE signal run the LFE signal to the subwoofer LFE in connector When daisy chaining multiple subwoofers run a cable from the Link Out connector the next subwoofer s Link In IN 3 IN 4 OUT 3 OUT 4 IN 5 OUT 5 IN 6 IN...

Страница 4: ...ency response of the whole system at the crossover frequency Figure 3 shows the effect of phase difference to the frequency response The phase difference between the main monitors and subwoofer at the listening position depends on the position of the subwoofer so the phase adjustment should be done only after the preferred position is found and subwoofer and monitor levels have been aligned GLM so...

Страница 5: ...should not be much bigger than needed for ventilation as this may cause unwanted acoustic effects Maintenance There are no user serviceable parts inside the subwoofer Maintenance or repair must only be done by a Genelec certified service Guarantee Genelec guarantees the subwoofers for two years against manufacturing faults or defects altering performance Refer to the reseller for full sales and gu...

Страница 6: ...Bass Roll Off 4 8 and 12 dB dB SPL 0 20 40 60 80 100 10 200 20 30 50 100 Hz Level vs Freq Hz 7370A 25 4 16 LFE channel Main channels Bass Roll Off 4 8 and 12 dB dB SPL Figure 5 The curves above show the main channel s frequency response with 85 Hz lowpass filtering the fre quency response of the LFE channel and the effect of the Bass Roll Off adjustment to the response of the 7360A Figure 6 The cu...

Страница 7: ...Standby ISS active Idle Full output peak 1 W 15 W 300 W 1 W 20 W 400 W SIGNAL PROCESSING SECTION Analog signal input connector XLR female balanced 10 kOhm Maximum analog input signal Analog input sensitivity 100 dB SPL at 1 m rotary level adjustment pin 1 gnd pin 2 non inverting pin 3 inverting 25 0 dBu 12 to 6 dBu Digital signal input connector XLR female 110 Ohm Digital signal output Thru connec...

Страница 8: ... Genelec Inc 7 Tech Circle Natick MA 01760 USA Phone 1 508 652 0900 Fax 1 508 652 0909 Email genelec usa genelec com In China please contact Beijing Genelec Audio Co Ltd Room 101 1st Floor Building 71 B33 Universal Business Park No 10 Jiuxianqiao Road Chaoyang District Beijing 100015 China Phone 86 10 5823 2014 Post code 100015 Email genelec china genelec com In Sweden please contact Genelec Sveri...

Отзывы: