Genelec 5040B Скачать руководство пользователя страница 3

and the subwoofer, the subwoofer should be 
placed close to the center of the front loud-
speaker array. 

Two phase matching switches in the 

crossover allow compensation for incorrect 
phase alignment. Four settings are provided 
between 0° and -270°. 

Coarse phase  

correction method

Connect an audio frequency signal generator 
to a signal input on the subwoofer which has 
a main loudspeaker connected to the corre-
sponding “OUT” connector. Set the generator 
to 85 Hz. If a signal generator is not available, 
then it is possible to use an audio test record-
ing which has a test frequency in the range 
70 Hz to 100 Hz. Suitable test signals can be 
downloaded at www.genelec.com.

•  Toggle the -180° phase 

 

  switch ‘ON’ and ‘OFF’ and  
  set it to the position which  
  gives the lowest sound level  
  at the listening position.

•   Next toggle the -90°phase 

 

  switch ‘ON’ and ‘OFF’, and  
  again set it to the position  
  which gives the lowest  
  sound level.

•   Finally, set the -180°phase 

 

  switch to the opposite  
 setting.

Automatic protection circuits

The 5040B is equipped with protection cir-
cuits against loudspeaker driver thermal 
overload and amplifier overheating. The pro-
tection system resets automatically so that 
the user only has to turn the input level down 
to ensure that it does not reactivate.

Safety considerations

The Genelec 5040B complies with interna-
tional safety standards. However, to ensure 
safe operation and maintain the equipment in 
safe operating condition the following warn-
ings and cautions must be observed.

•  Servicing and adjustment must only be 

 

  performed by qualified service personnel. 

•  Opening the amplifier panel is strictly 

 

  prohibited except by qualified service  
 personnel. 

•  Do not expose the subwoofer to water or 

 

  moisture. Do not place any objects filled 

 

  with liquid, such as vases on the  
  subwoofer or near it. 

•  Note that the amplifier is not completely 

 

  disconnected from the AC mains service  
  unless the mains cable is removed from  
  the amplifier or the mains outlet.

Warning!

This equipment is capable of delivering sound 
pressure levels in excess of 85 dB, which 
may cause permanent hearing damage.

Maintenance

There are no user serviceable parts inside 
the subwoofer. Any maintenance of the unit 
must only be performed by qualified service 
personnel. 

Guarantee

This product is supplied with two year guaran-
tee against manufacturing faults or defects that 
might alter the performance of the unit. Refer 
to supplier for full sales and guarantee terms. 

Compliance to FCC rules

This device complies with part 15 of the FCC 
Rules. Operation is subject to the following 
two conditions: 
This device may not cause harmful interfer-
ence, and This device must accept any inter-
ference received, including interference that 
may cause undesired operation. 

Note: This equipment has been tested and 
found to comply with the limits for a Class 
B digital device, pursuant to part 15 of the 
FCC Rules. These limits are designed to pro-
vide reasonable protection against harmful 
interference in a residential installation. This 
equipment generates, uses and can radiate 
radio frequency energy and, if not installed 
and used in accordance with the instruc-
tions, may cause harmful interference to 
radio communications. However, there is no 
guarantee that interference will not occur in a 
particular installation. If this equipment does 
cause harmful interference to radio or televi-
sion reception, which can be determined by 
turning the equipment off and on, the user is 
encouraged to try to correct the interference 
by one or more of the following measures: 

• 

Reorient or relocate the receiving 

antenna. 

• 

Increase the separation between the 

equipment and receiver. 

• 

Connect the equipment into an outlet 

on a circuit different from that to which the 
receiver is connected. 

• 

Consult the dealer or an experienced 

radio/TV technician for help.

 
Modifications not expressly approved by the 
manufacturer could void the user’s authority 
to operate the equipment under FCC rules.

Figure 1. Connectors and controls of the 5040B.

Содержание 5040B

Страница 1: ...Genelec 5040B Active Subwoofer 5040B Operating Manual Käyttöohje Manuel d utilisation ...

Страница 2: ...nd testing is needed to find the optimum place ment The placement will also affect the bass roll off rate and the phase difference between the main loudspeakers and the subwoofer These effects can be compensated using the con trols in the subwoofer but we recommend that at first you leave the switches untouched and concentrate on finding the position where the subwoofer gives the smoothest respons...

Страница 3: ... mains cable is removed from the amplifier or the mains outlet Warning This equipment is capable of delivering sound pressure levels in excess of 85 dB which may cause permanent hearing damage Maintenance There are no user serviceable parts inside the subwoofer Any maintenance of the unit must only be performed by qualified service personnel Guarantee This product is supplied with two year guaran ...

Страница 4: ...put 0 05 Mains voltage Fixed 100 120 or 230 V Power consumption average Standby Idle Full output 0 5 W 7 W 70 W 5040B Main channels IN OUT LFE channel IN unbal anced female RCA connectors Pin Ring gnd Stereo IN 3 5 mm Jack female connector Sleeve Tip Ring gnd Left channel Right channel Input impedance 10 kOhm balanced Main channel OUT gain referred to IN 0 dB CROSSOVER SECTION 5040B Subsonic filte...

Страница 5: ...oko järjestelmän äänenvoimak kuutta Kaukosäädin voidaan jättää myös kytkemättä jos äänilähteessä on sopiva äänenvoimakkuuden säätö Kytke viimeiseksi subwooferin virtajohto ja laita virta päälle Subwooferin sijoitus Bassotoiston taso ja tasapaino riippuu suu ressa määrin bassotaajuuksia tuottavan kai uttimen sijainnista huoneessa Suhteellisen pienikin siirtäminen voi aiheuttaa merkittävän muutoksen...

Страница 6: ...e samoin 90 vaihekytki melle Lopuksi käännä 180 vaihe kytkin vastakkaiseen asen toonsa Automaattinen ylikuormitussuojaus 5040B subwoofer on varustettu automaat tisella ylikuormitussuojauksella elementin puhekelan ja vahvistimen ylikuumenemisen varalta Jos suojaus kytkeytyy alenna äänen voimakkuutta Turvallisuusohjeita Genelec 5040B subwoofer on suunniteltu ja valmistettu täyttämään kansainväliset ...

Страница 7: ...men lyhytkestoinen teho kaiutin elementin suojauselektroniikka rajoittaa vahvistimen jatkuvaa tehoa 40 W Vahvistimen särö nimellisteholla THD 0 05 Verkkojännite 230 V Tehonkulutus keskimäärin Valmiustila Min Max 0 5 W 7 W 70 W 5040B RCA ottoliitäntöjä RCA antoliitäntöjä 6 kpl 5 LFE 5 kpl 3 5 mm stereojakkiliitin 1 kpl Ottoimpedanssi 10 kOhm Antoliitäntöjen taso 0 dB JAKOSUODIN 5040B Ylipäästösuodi...

Страница 8: ...hodiques avec patience afin de trouver l endroit idéal La position du caisson aura un effet sur la différence de phase entre les enceintes prin cipales et le caisson grave ainsi que sur l ex tension de la réponse dans les graves Ces effets peuvent être compensés et ajustés en utilisant les contrôles du caisson grave mais dans un premier temps nous vous recom mandons de ne pas utiliser ces contrôle...

Страница 9: ...tion automatique contre les surchauffes des transducteurs et des amplificateurs Le système de protection se remet en marche automatiquement et l utilisateur a seulement besoin de réduire le niveau d entrée pour éviter la réactivation du système de protec tion Considérations liées à la sécurité Le Genelec 5040B est conforme au normes de sécurité internationales Toutefois afin d assurer un fonctionn...

Страница 10: ...5 Voltage d alimentation 100 120 ou 230 V Consommation moyenne En veille En attente de signal Sortie maximale 0 5 W 7 W 70 W 5040B Canaux principaux IN OUT canal LFE IN connecteurs RCA femelles asymétriques Pin broche Ring anneau terre Stéréo IN connecteur femelle Jack 3 5 mm Sleeve manchon Tip pointe Ring anneau terre Canal gauche Canal droit Impédance d entrée 10 kOhm symétrique Gain de sortie O...

Страница 11: ......

Страница 12: ...ck MA 01760 U S A Phone 1 508 652 0900 Fax 1 508 652 0909 Email genelec usa genelec com In Sweden please contact Genelec Sverige Ellipsvägen 10B P O Box 5521 S 141 05 Huddinge Phone 46 8 449 5220 Fax 46 8 708 7071 Email info genelec com In China please contact Beijing Genelec Audio Co Ltd Jianwai SOHO Tower 12 Room 2605 39 East 3rd Ring Road Chaoyang District Beijing 100022 China Phone 86 10 5869 ...

Отзывы: