Genave Alert 150-AC Скачать руководство пользователя страница 3

Alert 150-AC 

Hardware Installation and User Guide 

 

9000-0000-128 Revision 00

 

3 of 23 

Genave Electronics

 

©2018, Genave/NRC, Inc.

 

Alert 150-AC

 Hardware

 

Phone 952-236-6540 

 
 

PRINTED IN USA

 

The contents of this manual are the property of Genave/NRC, Inc. and are copyrighted. Any reproduction in whole or in part is strictly 
prohibited. For additional copies of this manual or software, please contact Genave/NRC, Inc.

 

 
Warranty: 
Genave/NRC, Inc. products are warranted to be free from defects in material and workmanship for a 
period of ONE (1) year from the date of shipment. Genave, during this period, will repair or replace any 
parts, which upon our examination appear to be defective in materials or workmanship. This warranty 
does not apply to defects, malfunctions or breakage due to improper installation, servicing, handling or 
use thereof, nor to units that have been damaged by lightening or other “Acts of God”, excess current, 
reversed supply connection, nor to units that have had their serial numbers altered or removed. 
Equipment damaged in Acts of War, abuse, misuse, tampering, submersion or willful destruction will 
also void this warranty. 
Prior to returning equipment for warranty repair, contact the Genave Customer Service Department for 
an RMA number. They can be reached by using the telephone number or fax number listed above.  
Genave/NRC, Inc. (Genave) and its licensers offer this warranty in lieu of any and all other guarantees or 
warranties, either express or implied, including without limitation the implied warranties of 
merchantability and fitness for a particular purpose, regarding hardware or software. Genave and its 
licensors do not warrant, guarantee or make any representations regarding the use or the results of the 
use of the software or hardware in terms of its correctness, accuracy, reliability, most recent or 
otherwise. You assume the entire risk as to the results and performance. The exclusion of implied 
warranties is not permitted by some jurisdictions. The above exclusion may not apply to you.

 

 
In no event will Genave, its licensors, directors, officers, employees or agents (collectively Genave’s licensor) be liable to you for 
any consequential, incidental or indirect damages (including damages for loss of business profits, business interruption, loss of 
business information, and the like) arising out of the use or inability to use the software or hardware even if the Genave and/or its 
licensor has been advised of the possibility of such damages. Because some jurisdictions do not allow the exclusion or limitation 
of liability for consequential or incidental damages, the above limitations may not apply to you. Genave and its licensors liability to 
you for actual damages from any cause whatsoever, and regardless of the form of the action (whether in contract, tort, (including 
negligence), product liability or otherwise), are expressly excluded. 
 
Genave reserves the right to make changes in specifications at any time and without notice. The information furnished by Genave 
is believed to be accurate and reliable, however, no responsibility is assumed by Genave for its use, nor infringements of patents 
or other rights of third parties resulting from its use. No license is granted under any patents or patent rights of Genave/NRC, Inc., 
its licensors or suppliers. 
 
Life Support Policy: 
Genave/NRC, Inc. products are not authorized for use as critical components in life support devices or systems without the 
express written approval of the president of Genave/NRC, Inc. As used herein: 
 
1) Life support devices or systems are devices or systems which, (a) are intended for surgical implants into the body, or (b) 
support or sustain life, or whose failure to perform, when properly used in accordance with instructions, can reasonably be 
expected to result in a significant injury to the user.

 

 

2) Critical component is any component of a life support device or system whose failure to perform can be reasonably expected to 
cause the failure of the life support device or system, or to affect its safety or effectiveness. 

 

CSP, Communications Signal Processor, Genave Operating System, GOS, CSP-105, RXC-3000, LR900, LR-900, MP3 Node and Alert 

150 are Trademarks of Genave/NRC, Inc. The Genave name and logo are Registered trademarks of Genave/NRC, Inc.  

Other names used in this manual are trademarks of their respective companies.

 

 
 

 

 

Содержание Alert 150-AC

Страница 1: ...Alert 150 AC 150 Watt 4 Horn Siren PA Hardware Manual Genave NRC Inc www genave com support genave com Copyright 2018 Genave NRC Inc Tech Publication No 9000 0000 128 Rev 00...

Страница 2: ...e precautions to protect yourself and others You should completely disable the equipment before working on or in close proximity to any part of it You must test the system and equipment to insure it i...

Страница 3: ...officers employees or agents collectively Genave s licensor be liable to you for any consequential incidental or indirect damages including damages for loss of business profits business interruption l...

Страница 4: ...Alert 150 AC Hardware Installation and User Guide 9000 0000 128 Revision 00 4 of 23 Genave Electronics This page intentionally blank...

Страница 5: ...y on a pipe 12 Mounting to a pipe pole or parapet with H7050 0000 028 13 Suspending the head from a ceiling 14 Mounting Horns to the hub assembly 14 Mounting the control cabinet with flanges 15 Mounti...

Страница 6: ...pacity 12 Awg to 22 Awg Output Voltage 70 Vrms Power 150 Watts Wire Capacity 12 Awg to 22 Awg Remote Inputs Headers 2 pos 2 5mm Mating Connector 2 pos spring clamp 26 20 AWG P N 6000 0052 002 Input Vo...

Страница 7: ...rates special effect sounds upon activation of one of the 8 inputs When activated the MP3 Node powers up the 150 Watt amplifier and plays the associated MP3 file for the activated input Upon completio...

Страница 8: ...00 128 Revision 00 8 of 23 Genave Electronics What s Inside the Electronics Enclosure Optional LR 900 Node Antenna for Optional LR 900 Node User Control Board Power Control Board Optional Microphone S...

Страница 9: ...dware Installation and User Guide 9000 0000 128 Revision 00 9 of 23 Genave Electronics Assembling the Speakers Step 1 Insert the Speaker Driver into the horn as shown in the picture Speaker Driver Bra...

Страница 10: ...of 23 Genave Electronics Step 2 Install all 4 screws with washers attached into the 4 holes in the speaker driver as shown in the picture Step 3 Tighten the 4 screws securely so that the speaker drive...

Страница 11: ...Alert 150 AC Hardware Installation and User Guide 9000 0000 128 Revision 00 11 of 23 Genave Electronics Step 5 Attach the bracket with the two bolts Step 6 Tighten the bracket bolts...

Страница 12: ...r with a threaded end Do NOT use plastic pipe Do not exceed 10 feet of un guyed pipe to support the head Use locknuts above and below the hub plate on the pipe to secure the hub to the pipe Make sure...

Страница 13: ...tronics Mounting to a pipe pole or parapet with H7050 0000 028 When mounting the head to a wood pole a parapet or a pipe that either has an outside diameter than 2 1 2 or is not threaded it is best to...

Страница 14: ...nsion openings to secure 4 chains to the hub which then are connected to the ceiling Mounting Horns to the hub assembly The speakers can be mounted above or below the hub plate The normal configuratio...

Страница 15: ...istrut channels attached to the back Your Alert 150 AC comes with two flanges used when mounting the electronics cabinet to a wall wood pole or large diameter pipe Use Band It metal banding for large...

Страница 16: ...mportant Note Drill holes for cable on the bottom of the enclosure ONLY Never drill any holes in the sides or top of the cabinet The cabinet is water tight and will hold any water that enters which wi...

Страница 17: ...lert 150 AC The unit can accept 90 VAC to 250 VAC 50 60 Hz Transformer Output The output of the transformer is connected with two wires to the siren head The transformer also has the ability to drive...

Страница 18: ...ies parallel configuration The reasoning for this is to limit the maximum amount of power supplied to each speaker which increases longevity Additionally if one speaker becomes damaged and opens up th...

Страница 19: ...Dry Contact Inputs The remote inputs act exactly like pressing one of the switches When connecting to other equipment use only dry contacts relays mosfets or transistors Never apply any voltage to th...

Страница 20: ...Guide 9000 0000 128 Revision 00 20 of 23 Genave Electronics LR 900 Connections When connecting to an LR 900 the user interface switches are moved to the input of the LR 900 and the output of the LR 90...

Страница 21: ...as an ON OFF switch which allows you to turn off the siren however the power supply is not turned off by the switch only the DC output from the power supply is interrupted by the switch The schematic...

Страница 22: ...the LR 900 is used to activate sirens within a distance of to miles away Additionally LR 900 units repeat signals from the activation point which allows whole systems to be activated with very low sig...

Страница 23: ...Alert 150 AC Hardware Installation and User Guide 9000 0000 128 Revision 00 23 of 23 Genave Electronics This page intentionally blank...

Отзывы: