Gen3 AutoCAF2+ Скачать руководство пользователя страница 4

Page 

4

 of 

42

 

  

1

 

INTRODUCTION 

 

1.1

 

Software Licence 

 

Gen3, suppliers of the enclosed software, grants you a non-transferable, non-exclusive right to use this on 
only 1 single system. 
 
Title and all intellectual proprietary rights remain the property of Gen3. 
 
You may not modify the licensed software in any way. 
 
You may modify data files and system support files if you desire or if directed by Gen3. 

 

1.2

 

Copyright 

 
You may not use, copy, or modify the enclosed licensed software or any copy, in whole or in part except as 
provided in this agreement. 
 
Gen3 allows you to make one backup copy of the software for archival purposes only. The backup copy may 
only be used with the original system supplied. 

 

1.3

 

Extent of Warranty 

 
Gen3 warrants that the licensed software conforms to its program specification provided that the software is 
properly used on the A System. 
 
Gen3 shall remedy any breach of the warranty conditions by provision of a replacement software package 
provided that the notified fault is reproducible under normal use according to the instructions given in the 
manual. 
 

2

 

GUARANTEE 

 
All Gen3 equipment hardware and software is fully guaranteed to meet the CE standards of the European 
Union, and the warranty insures against faulty workmanship, operation or performance for a period of ONE 
YEAR from date of purchase by the user of the product. 
 
All  claims  against  this  guarantee  MUST  be  supported  by  evidence  of  purchase,  such  as  a  bill  of  sale  or 
invoice, and it is the responsibility of the claimant to furnish such proof. 
 
In the first instance claims should be made through the original agent from whom it was purchased. In the 
event of difficulty, users are requested to contact Gen3 direct, quoting the Serial Number of the system. 
 
Gen3  or  an  appointed  distributor  will,  at  their  discretion,  repair  or  replace  part  or  the  entire  product  to 
provide, in their judgement, a satisfactory performance of the system consistent with its age and apparent 
usage. 
 
This guarantee covers the cost of both parts and labour required to correct the malfunction, but specifically 
excludes wear and tear, consumables, physical damage due to incorrect use or misuse and damage or faulty 
operation due to unauthorised or inexpert repairs. 

 

 

Содержание AutoCAF2+

Страница 1: ...Page 1 of 42 AutoCAF2 INSTRUCTION MANUAL OPERATING GUIDE ISSUED 2021 23 06...

Страница 2: ...5 6 X Axis Format Selection Pages 16 17 5 7 Output Value Low Measurement Alarms Page 18 5 8 Temperature Humidity Interval Limit Setup Page 19 5 9 Board Channel naming selection Page 20 5 10 Standard...

Страница 3: ...Page 3 of 42 6 2 2 Connectors 6 2 3 Cables 6 2 4 Design 6 3 High Voltage Testing 7 AutoCAF2 Technical Specification Page 42 8 High Voltage Testing CLR1250 Bridge Page 43...

Страница 4: ...e under normal use according to the instructions given in the manual 2 GUARANTEE All Gen3 equipment hardware and software is fully guaranteed to meet the CE standards of the European Union and the war...

Страница 5: ...54 x 39cm in size Before opening check the crate for any external damage that may have occurred during delivery If the crate has sustained any serious damage the carrier should be contacted immediate...

Страница 6: ...amework 4 7 2 installer MCP 2221 Windows Driver Operating Manual Facts and Data book SIR CAF Testing Note If you are not permitted to use USB Flash drives please contact techsupport gen3systems com an...

Страница 7: ...e readings therefore the measurement cabling should always be fully screened The unit should be placed onto a stable surface and away from areas where it could be disturbed If the AutoCAF2 is placed c...

Страница 8: ...ained by hand is likely to expose live parts The apparatus shall be disconnected from all voltage sources before it is opened for any adjustment replacement maintenance or repair Capacitors inside the...

Страница 9: ...nd plug it into the mains socket at the rear of the unit Connect USB cable between AutoCAF2 and USB port in the PC Switch on the unit using the on off switch located to the rear of the unit The AutoCA...

Страница 10: ...escribed herein shall be deemed to be a warranty by Gen3 for any purpose or give rise to any liability by Gen3 whatsoever In no event shall Gen3 be liable for any accidental indirect special or conseq...

Страница 11: ...allation Open the AutoCAF2 folder on the provided USB and open the exe file to begin software installation on the first screen choose the desired filepath for installation then select next Figure 2 On...

Страница 12: ...stage select Finish Figure 4 5 2 Language Selection Upon opening the AutoCAF2 software for the first time a language selection screen will appear once selected the software will upon N B Once languag...

Страница 13: ...sion of software that is installed it also contains a link to the Gen3 website Figure 7 N B The version pictured may not be the current revision of software received on the USB stick 5 4 Manual The Au...

Страница 14: ...automatically appear in the drop down menu and which machine type either a 64 128 or 256 The user will also have the option to choose if applicable which CLR bridge to attach N B The correct machine...

Страница 15: ...Page 15 of 42 Figure 11 The following shows an example of a graph with Measurement set as the X Axis this test shows 1min intervals for 10 measurements Figure 12...

Страница 16: ...he following shows an example of a graph with Minutes set as the X Axis this test shows 1 min intervals for 10 measurements Figure 13 The following shows an example of a graph with Hours set as the X...

Страница 17: ...resistance alarm limit can be set if Log10 Resistance is selected then the low measurement must be set in Log scale N B Any measurement record that falls below this limit will be recorded in the Alar...

Страница 18: ...imit Setup During this setup process if a Temperature Humidity probe is required the Minimum and Maximum alarm limits must be set N B Any T H measurement that falls outside of the desired ranges will...

Страница 19: ...s Channels to change the window to the board and channels settings On this screen to turn on and off desired boards and channels simply click on the tick boxes to turn on and off to rename boards and...

Страница 20: ...Measurements this is not editable it is a calculation between the test length and measurement interval 4 Measurement Interval 24 hour format 5 External Voltage greyed out unless either is selected in...

Страница 21: ...Page 21 of 42 5 11 Multiple Bias Test The below shows an example of the form change if multiple Bias selection is required Figure 21 Figure 22...

Страница 22: ...e of the Test Parameters form if a predefined custom template is selected Figure 23 After a template has been selected if any of the predefined parameters are changed when the test start is selected t...

Страница 23: ...tive throughout the duration of the test and will disappear once the test is completed Figure 25 When a test is started using an external voltage over 300V a high voltage test running bar will appear...

Страница 24: ...e options the user is free to use the software including 1 Communications Test Log 2 Low Measurement Alarm Log see section 5 16 3 Measurement Timer 4 Live Data see section 5 17 5 Temperature and Humid...

Страница 25: ...elect Alarms in the toolbar Figure 28 The alarms window displays the following information for each measurement that drops below your chosen Alarm limit 1 Timestamp of most recent recording for releva...

Страница 26: ...button scroll with a mouse over the graph title Figure 30 The user can also zoom in anywhere on the live data chart to view a specific data set scroll to a set point using a mouse and then use the sc...

Страница 27: ...to hover over a particular channel to be shown the Board and Channel name also displayed will be the value of measurement in either Log Resistance or Resistance in M Log10 Resistance Output Value Fig...

Страница 28: ...f of the user interface data for temperature and humidity and each measurement board can be viewed To switch between graphs simply select an available graph on the bottom left of the user interface to...

Страница 29: ...nnels this can be done by clicking on the required channel in the index on the right hand side of the graph N B If a channel is turned off this is merely for viewing purposes on the graph the channel...

Страница 30: ...n measure is a function of the test voltage and will happen the following maximum limits for each test voltage available from the Bias Power Supply Selectable Test Voltage Maximum Resistance 3 3V 12 0...

Страница 31: ...sults graphs as a JPEG file at any desired location To do this right click using a mouse anywhere on the graph and select save Figure 38 Once save has been selected a new window will appear asking for...

Страница 32: ...irectly print either of the two resulting graphs To do this right click using a mouse anywhere on the desired graph and select print Figure 40 Once print has been selected a new window will appear sho...

Страница 33: ...s open the Export option in the toolbar and then select alarms to export the log as a csv file Figure 42 Once Alarms has been selected a new window will open where the filepath must selected and the f...

Страница 34: ...then select report Figure 45 This will open the results in a report format with test information on the first page followed by all available results graphs from the boards that were selected for the...

Страница 35: ...ct new spreadsheet Figure 47 Selecting new spreadsheet will open a new window requiring the user to select the filepath location and name the resultant excel spreadsheet Figure 48 In the resultant spr...

Страница 36: ...or the test file open the filepath location and open the Gen3 file Figure 50 This will reload the data into the AutoCAF2 software which can then be used to manipulate all data readings graphs and expo...

Страница 37: ...he settings can be reset to default factory settings by holding CTRL and closing the software Figure 52 Once the software is closed a new window will appear confirming that the settings file is to be...

Страница 38: ...s also known as guard bands Figure 52 The wires should be separated into pairs measurement and ground and the insulation stripped from the measurement wire at the free end The stripped measurement wir...

Страница 39: ...est program BIAS 3 For connection of internal or external bias to the test site only when using the BELLCORE 25 test program COM For connection of external bias power supply commons INTERLOCK This soc...

Страница 40: ...supplied fitted with four Halogen Free measurement cables 2 25m in length with screening to minimise cross talk between measurement channels 6 2 4 Design Due to the test racks versatile design it may...

Страница 41: ...external power source Bias Voltage Accuracy internal power source 0 3 at 100V Equilibration Voltage Delay Prior to Measurement Up to 40 seconds less than measurement interval Number of Test Points 16...

Страница 42: ...nplugged either the input socket 1250V or the output socket 300V there is no risk to the operator safety from the Bridge Box 3 Coupon Connecting Cable a In compliance with system integrity performance...