www.gemu-group.com
17 / 32
GEMÜ 1242
DeviceNet
9.3 Assembling the adapter (linear actuator)
With some mounting kits it is necessary to install an adapter as well. This adapter is enclosed with the required mounting kits.
Valves with a normally open and double acting control function (code 2+3) also include additional O-rings (1+2).
1
3
2
1. Move the actuator to the closed position.
2. Place O-rings
1
and
2
into adapter
3
.
3. Screw adapter
3
into the actuator opening as far as it will go and tighten.
9.4 Assembling the stroke limiter (linear actuator)
5
5
4
3
2
1
6
8
9
7.1
7.2
Option1
Option2
1. Screw distance piece
5
onto/into actuator spindle
6
.
2. Move the actuator to the closed position.
3. Insert the O-ring
7.1
in the stroke limiter
1
.
4. Insert the O-ring
7.2
in the washer
4
.
5. Screw stroke limiter
1
with nut
2
, seal
3
and washer
4
into the actuator opening.
6. Set stroke limiter
1
to the required stroke.
7. Make sure that the minimum stroke is reached.
8. Secure stroke limiter
1
with nut
2
.
Key
1
Stroke limiter
7.1
1)
7.2
1)
O-ring
2
Nut
8
Protective cap
3
1)
Seal
9
Position indicator
4
1)
Disc
10
Operating bush
5
2)
Distance piece
11
Spindle
6
Actuator spindle
12
Travel sensor
1) Only available for valves with the NO and DA control functions.
2) Only included in required mounting kits. The design depends on the valve.
9.5 Assembling and installing the electrical position indicator
DANGER
Danger of explosion
▶
Danger of death or severe injury.
●
Do not use the product as a step or foothold.
●
Prior to commissioning, ensure that the cover is fully closed and that the housing and the O-ring are not
damaged.
Assembly and installation
Содержание GEMU 1242