- 31 -

PARTS LISTS

Rep

.

Reference

Designation

1

N40.10637

PP. PIPE D.80 LENGTH 445 

2

A00.23624

PE CAP N152 BPF 3-1/2 

3

Y00.14139

FASTENING HOOK 

4

Y00.10807

FIXING SYSTEM FOR FLUE PIPE 

5

Y00.13849

BACK STOP PLATE FOR MZ (3355X80,4X1,5) 

6

Y00.18233

RIGHT HAND CONSOLE (269,4X25X1,5) 

7

V07.31963

WALL FASTENING ; 10-50 MODEL 

8

Y90.33470

CHASSIS ; EQUIPPED THI 10-50 

9

W07.31704

MOTOR;  SELECTIVE VALVE WITH CABLE 

10

E00.01005

O’ RING DIA DIA 29,32 X 3,6 

11

L90.24635

AUTOMATIC AIR VALVE WATTS WITH ISOLATED VALVE 

12

U07.34049

HEATING FLOW; GREY; THRI SEP 

13

E20.03889

SEALING AFM34D 30X21X3 

14

A00.19059

PLASTIC STOPPER MAL 9 WHITE 

15

V90.33015

SELECTOR VALVE KIT 

16

U90.28983

HEATING RETURN UNIT 

17

I20.21441

MESSING SEALED CONNECTION "OLIVE" 22/1 

18

V00.23999

STOP PLATE FOR HEATING AND DHW 

19

V00.21491

PROTECTING RING 1 

20

I20.21452

MESSING LOCK NUT 1 

21

O00.32983

RIGHT FLEXIBLE PIPE NU 1/2 LG 350 

22

O00.32984

RIGHT FLEXIBLE PIPE NU 1/2 LG 550 

23

U07.32871

PRIMARY OUTLET PIPE 

24

L50.35152

PRESSURE SENSOR HUBA TYPE 505.91540 

24

V90.35156

REPLACEMENT SET OF IMIT SENSOR BY HUBA SENSOR 

25

L90.24178

SAFETY VALVE 

26

I20.33459

CONNECTION 1’’ -3/4’’ 

27

L30.33738

CIRCULATING PUMP GRUNDFOS UPS15-70/130 AO S3 

28

U00.19252

SUMP INLET  THRC/S GREY 

29

A20.23655

SIPHONIC TRAP WITH PIPE 650 MM 

30

W07.36930

CONTROL BOX ; WIRED ; PROGRAMMED 

31

U07.31500

GAS INLET; EQUIPPED; 1/10 -  5/25 MODEL 

32

Y90.35965

WHITE COVER THRI S/10-50C 

33

T25.31875

FIXING PART; UPPER COVER 

34

O00.20679

STAINLESS STEEL FLEXIBLE PIPE MALE 1/4 WITH ELBOW 

35

H20.32834

FRONTPANEL GREY 

36

Y07.32843

COVER + FRONTPANEL 

37

V07.32114

RING FOR BOILER COVER  L685 

38

L20.31470

SENSOR TASSERON NTC SENSOR M5 TSA-TYPE 

39

L10.10607

HONEYWELL O’RING 22 X 2,5 

40

V90.33616

WIRED SIT GAS VALVE SET 

41

E20.06892

SEAL AFM34 D. 18,6 X 12    2 MM THICKNESS 

42

L10.33774

FLANGE G 3/4"  FOR SIT VALVE 

43

U07.31563

GAS INLET; COMPLETE BURNER ; 10-50C MODEL 

44

U07.31498

90° ELBOW ; D.80 DRILLED 

45

L20.31496

SENSOR TASSERON NTC SENSOR D10X20 10K 

46

T20.00582

SIGHTGLASS  PYREX D.30X5 

47

B59.00692

STAINLESS STEEL WASHER 30,4X25,5X0,3 

48

T40.01051

INSIDE CIRCLIPS D.30 YELLOW  BICHROMATE 

49

L00.16673

IGNITION ELECTRODE SHORT 74,5 AV CABLE 

50

L00.12950

IONISATION PROBE (SHORT 20) 

51

X00.24278

BURNER SET NG/LPG FOR THR 10-50 C 

52

X00.32003

BURNER RING; REMOVABLE 

53

F00.26573

GLASS BRAID RING D. 12 LG. 1070 

54

V07.33783

STAINLESS STEEL BOILER SHELL THRI/THI/THISION10-50 

Содержание THI 10-35 SEP

Страница 1: ...T E C H N I C A L High technology heating I N S T R U C T I O N S THI 10 50 C THI 10 35 SEP T30 36295 02 SERVICING Commissioning Gas conversion Maintenance Operating faults Options Parts lists...

Страница 2: ...ropane to Natural gas 9 2 GAS CO2 CO NOX FLOW CONTROL AND SERVICE PRESSURE CONTROL 10 2 1 Surveillance procedure 11 2 2 Setting table 12 III MAINTENANCE 13 1 SERVICING THE FAN AND THE BURNER 13 2 SERV...

Страница 3: ...50 C 22 6 PROGRAMMABLE RELAY CLIP IN KIT REG 127 22 7 PROGRAMMABLE RELAY CLIP IN KIT WITHOUT SENSOR REG 134 23 8 CONTROL UNIT ZHTI 46 REG 129 23 9 CONTROL UNIT ZHTI 47 REG 128 23 10 SOLAR HEATING CONT...

Страница 4: ...version of BIONI BAL Antifreeze with glycol monopropylene base corro sion inhibitor biocide traceable In addition to the characteristics of BIONIBAL it pro tects the installation from frost for resid...

Страница 5: ...contained in the piping so that the boiler has an adequate fuel The presence of air in the gas prevents the igni tion of the burner and leads to safety shut down by the flame monitoring unit This is...

Страница 6: ...593 Failure to do this may invalidate the warranty 7 USER INFORMATION The heating engineer must inform the user about the unit s operating mode In particular the user must be informed about the functi...

Страница 7: ...er only Basic boiler model without outside sensor and room sensor Auto mode is inaccessible The hot water temperature is set manually by using the boiler potentiometers Boiler with outside sensor only...

Страница 8: ...th the two latch F connect the terminal of the earth wire O positio ned in the boiler to the tab on the front panel G shut the front panel using the two latch F on the top of the boiler lock the 4 lat...

Страница 9: ...burner Gently separate the fan 7 from the burner 4 at the level of the flange 3 Take off the air reducer 6 into the air inlet sleeve of the burner Gently refit the fan 7 together with its joint to th...

Страница 10: ...mmCE and a CO2 CO analyser To modify the setting if it is required take off the protection screw and screw to increase the gas flow When the ad justments are realized reset the protection screw Fig 5...

Страница 11: ...fig 5 page 10 SERVICING MA NUAL to obtain a stable flame Check the CO2 CO ratio see setting table section 2 2 page 12 chapter II GAS CON VERSION SERVICING MANUAL Set the d h w potentiometer 3 to the m...

Страница 12: ...07 36237 Heat output 30 50 C 60 80 C kW kW 10 7 52 6 9 7 48 7 10 7 36 0 9 7 33 1 Heating Heating D H W Heat input kW 10 0 50 0 10 0 35 0 10 0 50 0 Gas reducer Nat gas H Propane mm mm 6 40 Air reducer...

Страница 13: ...g the type and serial number of each part Before any servicing cut the power supply Close the gas inlet of the boiler and the isolation valves if required If the boiler is removed provide a port at th...

Страница 14: ...place the seal at the nut item 9 and check the airtightness of the gas when refitting the fan on the burner check the correct positioning of the fan burner gasket item 10 check the airtightness of the...

Страница 15: ...adjust the filling pressure of the installation to a value of over 0 2 bar above the pre inflation pressure of the vessel after totally bleeding the air from the installation 5 COMBUSTION PRODUCT COND...

Страница 16: ...624 10 00 C 19897 15 00 C 15711 20 00 C 12493 25 00 C 10000 30 00 C 8056 40 00 C 5324 50 00 C 3599 60 00 C 2483 70 00 C 1748 80 00 C 1252 90 00 C 912 Resistance values of the sensors Temperature Outsi...

Страница 17: ...dentical addresses on the LPB Check the addressing Loss of data in the EEPROM Change the LMU Component fault in the LMU Change the LMU Two master clocks only one normally programming problem Check par...

Страница 18: ...current value Segment number or unauthorised addressing on LPB or LMU Check the addressing consistency Incompatibility between the LMU and LPB Check the addressing consistency New LMU configuration Ch...

Страница 19: ...the error codes pre vail The maintenance alarm is sent until the enduser has acknowledged the message or the heating engineer has rectified the fault The maintenance alarm does not provide detailed i...

Страница 20: ...ed that is the maintenance alarm will reappear on the display after a certain period of time An ack nowledgement can also be made then This period of time starts after each acknowledgement The repetit...

Страница 21: ...LMU control unit to different units or accessories of the type RVA 46 zone regulator RVA 47 cascade regulator others distance management etc Refer to kit installation instructions 3 SECONDARY CIRCUIT...

Страница 22: ...s LMU management unit the 2nd circuit pump control and also the mixer valve motor accessories supplied with the kit The clip in relay allowing a 1st circuit pump Q8 CC1 to work in parallel and to regu...

Страница 23: ...ssembly instructions for the kit 8 CONTROL UNIT ZHTI 46 REG 129 The control unit ZHTi 46 enables an additional hea ting circuit to be controlled Required from 3 heating circuits refer to technical spe...

Страница 24: ...NSOR KIT The DHW sensor kit allows the connection of the do mestic hot water sensor to the hot water heater at the boiler control unit Refer to kit installation instructions 12 SELECTOR VALVE KIT FOR...

Страница 25: ...llation instructions 14 BS TYPE DOMESTIC HOT WATER PRODUCTION SYSTEM BS domestic hot water production systems can pro duce hot water when the installation contains a boil er that only operates for hea...

Страница 26: ...FT PUMP The condensate lift pump is used to raise the con densate extraction level for a direct outlet to the ex terior It is used for boilers installed in a basement Fig 26 BIONIBAGEL 10 litres Fig 2...

Страница 27: ...27 VI PARTS LISTS THI 10 50 C...

Страница 28: ...IT SENSOR BY HUBA SENSOR 25 L90 24178 SAFETY VALVE 26 L20 31471 SENSOR T7335D1024B 27 L30 33738 CIRCULATING PUMP GRUNDFOS UPS15 70 130 AO S3 28 U00 19252 SUMP INLET THRC S GREY 29 A20 23655 SIPHONIC T...

Страница 29: ...91 03071 WIRE CARRIER 65 I20 13579 BRASS NIPPLE MAL3 4 MAL3 4 LONG 66 A00 19059 PLASTIC STOPPER MAL 9 WHITE A00 28827 PLASTIC CAP MALE 1 4 C09 31469 CABLE WITH RECTIFIER VDU GAS VALVE C09 33608 CABLE...

Страница 30: ...30 PARTS LISTS THI 10 35 SEP...

Страница 31: ...FETY VALVE 26 I20 33459 CONNECTION 1 3 4 27 L30 33738 CIRCULATING PUMP GRUNDFOS UPS15 70 130 AO S3 28 U00 19252 SUMP INLET THRC S GREY 29 A20 23655 SIPHONIC TRAP WITH PIPE 650 MM 30 W07 36930 CONTROL...

Страница 32: ...03890 SEALING AFM34 D 24X17X3 69 L40 32888 DOMESTICCOLDWATERFILTERSTAINLESSSTEEL D 18 5 EXT 70 L50 35756 FLOW LIMITER 16 L MN 71 T40 32887 COPPER SEALING D 16 INT 72 K20 23797 3 4 1 2 CONNECTION BRASS...

Страница 33: ...33 PARTS LISTS CONTROL BOX...

Страница 34: ...CAL TERMINAL BOX W07 31558 ELECTR CONTROL PANEL WIRING 0 9 9 THISION W07 31562 CONTROL BOX PROGRAMMED THRI THI 10 50C DT W07 32380 CONTROL BOX WIRED PROGRAMMED THI 5 25 S DT W07 32381 CONTROL BOX WIRE...

Отзывы: