To reset the system proceed as follows:
• Disconnect the system.
• Short-circuit the RED and BLACK wires of the 2-pin LED connector.
• Connect the system; once the alarm system is powered, 4 acoustic signals will sound and the turn
indicators will flash 4 times.
• Remove the previously created short-circuit; the status LED lights up steady.
• Turn ignition key “ON”; reset is confirmed by an acoustic signal and the wailing of the siren for about
3 seconds.
• Turn ignition key “OFF”. The LED turns OFF and there are no acoustic signals.
By activating the following procedure, the system returns to the
state.
This procedure must therefore only be used in case of need, before programming the
system or auto-learning the turn indicators flashes.
factory default
!
12.0 - ULTRASONIC VOLUMETRIC PROTECTION
12.1 - CONNECTIONS AND POSITIONING
12.2 - SENSOR ADJUSTMENT
Insert the WHITE connector in the “W” marked socket.
Insert the RED connector in the “R” marked socket.
Install the transducers for the ultrasonic sensors on the top part of the windshield internal pillars, away
from the air vents and point them towards the center of the rear window.
sensors
:
• Set the trimmer to an intermediate position (medium sensitivity).
signal a presence.
f the sensitivity level
.
To check the
sensitivity level proceed as follows
• With the alarm system disarmed, roll down the front window about 20 cm.
• Close all doors, bonnet and boot and arm the system.
• During the system neutral arming time introduce an object in the cabin through the window
and move it around; the status LED will turn off to
• I
is too high or too low, readjust the trimmer and repeat the above procedure
ULTRASONIC
CELLS
CONNECTIONS
SENSITIVITY
ADJUSTMENT
14.0 - TECHNICAL SPECIFICATIONS
Power supply
Engine immobilizer relay contact capacity
Current absorption @ 12Vdc with system armed and LED flashing
Working temperature range
Turn indicators relay contact capacity
Alarm cycle duration
Maximum positive current output when armed (+A)
Maximum load of siren output
12 Vdc
15 mA
-30°C to +70°C
8 A to 20°C
30 sec.
8 A to 20°C
700 mA
1 A
13.0 - SYSTEM RESET
15.0 - WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT DIRECTIVE (WEEE)
The present device does not fall within the scope of Directive 2002/96EC on Waste Electrical and