The salt dissolving process can be accelerated using the pool cleaner. Check the salt
concentration is between 5 and 6kg/m3 using a measurement kit of any pool shop.
The operating of the chlorinator implies no salt consumption. However, the salt
concentration may be reduced with the passage of time due to rain or other freshwater
contributions. Whenever the salt needs to be added, pour the salt as near as possible to
the return lines.
Strictly recommended, do not pour the salt in the skimmers or the drain
inlet.
6. Operating
The above screen appears when the salt chlorine generator is switched off. To switch on or off the
chlorinator, press the MENU ON / OFF. For reach the setup menu press the same button for 3
seconds.
This display indicates the production level (CL = 100%), the measured pH, the availablity of the
production of the existing salt level and the direction of polarization at the bottom left arrow. If the
arrow indicating the polarization direction is moving, chlorine is produced, but if the arrow does not
move, the chlorine production is stopped. The A mark on the display indicates that the dosing pump is
in automatic mode, and the drop mark indicates that the dosing pump is running. Using the arrows
on the main screen, a chlorine production rate of 0% (chlorine production stopped) to 100% (full
efficiency) is selected as needed.
For back to the other setups pres the MENU button.
You need to make the setting according to your pool depending on the different conditions (number
of swimmers, temperature, etc.). In general, we recommend setting the minimum production
percentage that produces a crystal clear water in your pool.
Polarity Change Period
The polarity applied to the cell is periodically reversed to dislodge accumulations of lime. This period
is determined 8 hours by the manufacturer. Depending on the condition of your pool it may be
necessary to reduce this period up to 1 hour to increase the frequency of cleaning. The longer this
period is, the longer the electrode cell duration will be. A period of less than 4 hours will reduce the
length of the electrode. We recommend, therefore, to set this to the larger number of hours as
possible while you don’t see limescale on the cell.
When you enter the menu, press the OK key on the screen shown above and then use the OK button
to set the desired time with the arrows on the following screen.