Cell
The cell (3) needs to be in the housing making sure that the open outer zone
coincides with the water inlet tube. Make sure the o’ring(6) is in its place and not
to leak. Afterwards, connect the DC cable to the cell terminals.
NOTE: The cell connector is designed to ensure optimum electrical contact with
the cell terminals and pressing slightly may be required for its placement. Before
connecting this, please make sure the smallest orifice is aligned with the
corresponding terminal.
If you use a sand filter, open it and add 2 to 3 cm of sand above the upper
pipe.
The hose of the Ph dosing pump should be installed in the system in such a way
that the water does not contact other equipment.
pH Flow Cell
The Ph reducer injection should be after the electrolysis cell.
Otherwise, cell electrics will interfere with the acid and will be damaged
by corrosion and will be out of warranty. Do not locate acid tanks where
there is insufficient flow. Otherwise, electronic components can be
exposed to corrosion due to acid effect. The location of the flow cell
should be before the chlorine cell, otherwise high-density chlorine can
damage the flow cell and cause the product to go out of warranty.
After measure water pH, measured water is injected
to return line with a clamp settle.
Suction Collector
The sample is taken from the
water and sent to the pH flow
cell for measurement and
returned to the system.
The water from the suction
collector is connected to
the flow
cell for
measurement.