3.1.2 Setting up the valve battery.
Valves battery is delivered completely equipped, with
four or five valves, (depending on your order), and its
manometer panel with its corresponding connections.
Filters connections may be flange polyester outlets of
Ø200 up to Ø250 or with PVC outlets of Ø63 up Ø160.
Check the filters if they are situated in the suitable
distance from batteries and that they are lined-up.
You can start placing the battery avoiding forcing the
flanges. Check also that outlets have not been damaged
and that they are completely clean and empty.
3.1.3 Manometers.
On pool filters, when the filter is clean, the usual
pressures are:
-Inlet pressure: 0.8-1 Kg/cm2
-Outlet pressure: 0.4-0.6 Kg/cm2
When the differential pressure between the two
manometers is 1 Kg/cm2 or higher, backwash must be
carried out.
NOTE: Once the manometers have been installed, you
should cut the two little caps that are placed in the
backside of the panel.
These caps have been put there to avoid the spilling of
the manometer’s glycerin.