2 SafeNet Luna Remote PED Installation and Configuration
The PED then prompts for the HSM SO's blue PED key. Insert it and press
Enter
. A successful login confirms that
the Remote PED connection is running properly.
Begin using and administering the remotely located SafeNet Luna HSM appliance via SSH session, and providing
PED key authentication via the workstation-connected Remote PED whenever requested. Review the
SafeNet Network HSM Help for information about timeouts with respect to Remote PED.
Note:
Remote PED is served from a host computer running SafeNet Luna Client PED Server
software. A Remote PED session is called by an instance of PED Client running on the
computer hosting the SafeNet Luna HSM. In some cases, such as SafeNet Luna Network
HSMs behind strict firewalls, the HSM host is not allowed to initiate the connection. In that
case, you can initiate a Remote PED session from the PED Server side, providing that the
computer hosting the PED has obtained and registered the SafeNet Luna Network HSM's
server.pem
certificate.
SafeNet Luna Network HSM Installation Guide
Release 7.0 007-013576-002 Rev. A June 2017 Copyright 2001-2017 Gemalto All rights reserved.