Rev. 00 09/22
UA05
Fault clearance
•
47
Fault clearance
ATTENTION
Malfunctions may be fixed by trained personnel only!
Error messages on the CM40 (CM30) axis control or on the
position regulator are also to be observed!
Fault
Cause
Corrective action
Axis does not move
Error message(s) on
the axis control unit
Eliminate the error
and quit the
message
Linear guide unit is
blocked, runs rough
check the support
roller and set, if
necessary (see
chapter "Setting the
support roller")
control unit defective
repair or replace
Connecting cables
between the control
unit and the axis not
connected or
defective
connect, repair
Drive motor defective
replace
position regulator
defective
replace
Toothed belt not tight
or defective
tighten or replace
Safety grid not closed
close
Travel distance
incorrectly set
set correctly
Travel distance too
short or too long
incorrect settings on
the axis control
set correctly
During referencing,
the axis moves in
the wrong direction
The system
parameter “Change
direction of
movement” is set
incorrectly
adjust the system
parameter "Change
direction of
movement" (see axis
control operating
manual)
Содержание UA05
Страница 5: ...Rev 00 09 22 UA05 Table of contents 5 ...
Страница 6: ......
Страница 12: ...Rev 00 09 22 12 Safety UA05 ...
Страница 14: ...Rev 00 09 22 14 Transport UA05 ...
Страница 24: ...Rev 00 09 22 24 Product description UA05 ...
Страница 28: ...Rev 00 09 22 28 Assembly Connection UA05 ...
Страница 32: ...Rev 00 09 22 32 Start up UA05 ...
Страница 34: ...Rev 00 09 22 34 Operation UA05 ...
Страница 42: ...Rev 00 09 22 42 Maintenance Repairs UA05 4 5 6 ...
Страница 43: ...Rev 00 09 22 UA05 Maintenance Repairs 43 7 8 9 ...
Страница 44: ...Rev 00 09 22 44 Maintenance Repairs UA05 10 11 12 The carriage should run evenly and quietly again ...
Страница 54: ......
Страница 56: ...Rev 00 ...