Internal pressure regulators
Internal pressure regulators
Values set by factory (static):
Pressure regulator no.
Standard
Operation
Hot-Coating
Operation
1
Injector
(Vacuum)
3.5 bar
3.5 bar
2
Pinch valve
Transport
2.4 bar
3.0 bar
3
Pinch valve
Cleaning
5.0 bar
5.0 bar
Indicator
BACK PRESSURE
0.3 – 1.0 bar
0.3 – 1.8 bar
Checking the injector set pressure
The set pressure can be checked by simple disconnecting/switching of
the pneumatic hose.
1.
2.
Checking the injector set pressure