![Gema OptiSpray DPP01 Скачать руководство пользователя страница 18](http://html.mh-extra.com/html/gema/optispray-dpp01/optispray-dpp01_operating-instructions-and-spare-parts-list_2206663018.webp)
V
03/13
16
•
Start-up and operation
OptiSpray DPP01
OptiSpray DPP01 - start-up
Configuration
The start-up of the OptiSpray DPP01 Dense phase pump takes place ac-
cording to following instructions:
1. Connect the compressed air supply (6 bar)
2. Connect the power supply (100-240 VAC)
3. Ensure
the
grounding
4. Switch on the OptiSpray DPP01 Dense phase pump
5. Adapt the adjusting parameters for total air and powder out-
put (see also the CG09-P operating instructions)
6. Adjust the fluidization on the control unit
7. Start the pumping procedure by pressing the gun trigger
Fluidized powder hopper
The powder is fluidized in the powder container by fluidizing air forced
through a porous plastic plate from below. Thereby, the powder becomes
loose and acquires fluid-like characteristics.
Note:
For a better understanding of the interrelationships in powder coat-
ing, it is recommended to read completely the operating instruc-
tions of the control unit and the powder gun, so as to be familiar
with their functions too!
Connection and control
Connection by the Control IN connector
The OptiSpray DPP01 Dense phase pump is connected and controlled
with CG09-P Gun control unit by the
Control IN
connection.
OptiSpray
DPP01 Dense
phase pump
CG09-P
Gun control