Fault clearance
OptiSelect Pro GM04-E
Incident
Causes
Corrective action
Gun achieving only poor
spray profile
Total air incorrectly configured
Increase the powder quantity
and/or total air volume on the
control unit
Bend or damage to air lines to
injector
Check air lines to injector
Insert sleeve in the injector
worn or not inserted
Replace or insert it
Fluidization not running
see above