Incident
Causes
Corrective action
H11 (Help code on control
unit)
Gun not connected
Connect the gun
Gun plug or gun cable defective
Contact local Gema
representative
Powder does not adhere to
object, although the gun is
triggered and sprays powder
High voltage and current
deactivated
Check the high voltage and
current setting
High voltage cascade defective
Contact local Gema
representative
Nozzle defective
Replace
The objects are not properly
grounded
Check the grounding
The gun does not spray
powder, although the control
unit is switched on and the
gun trigger is pressed
Compressed air not present
Connect the equipment to the
compressed air
Insert sleeve in the injector
module clogged or not inserted
Clean or insert the
corresponding part
Nozzle in the injector module
clogged
Clean the corresponding part
Cup not tightened well
Tighten the cup
Pressure valve in the control
unit defective
Replace
Solenoid valve in the control
unit defective
Replace
No conveying air:
– Throttle motor defective
– Solenoid valve defective
Contact local Gema
representative
Front plate defective
Contact local Gema
representative
Содержание OptiSelect Pro GM04-CF
Страница 18: ...Rev 00 03 20 18 Product description OptiSelect Pro GM04 CF ...
Страница 26: ...Rev 00 03 20 26 Operation OptiSelect Pro GM04 CF ...
Страница 32: ...Rev 00 03 20 32 Maintenance Repairs OptiSelect Pro GM04 CF Dismantling procedure 1 2 3 ...
Страница 38: ...Rev 00 03 20 38 Disposal OptiSelect Pro GM04 CF ...
Страница 47: ...Rev 00 03 20 OptiSelect Pro GM04 CF Spare parts list 47 Other accessories Gloves anti static 1 pair 800 254 ...
Страница 48: ......
Страница 50: ...Rev 00 ...