![Gema OptiSelect Pro GM04-CF Скачать руководство пользователя страница 16](http://html.mh-extra.com/html/gema/optiselect-pro-gm04-cf/optiselect-pro-gm04-cf_operating-instructions-and-spare-parts-list_2206657016.webp)
Rev. 00 03/20
16
Product description
OptiSelect Pro GM04-CF
Flat jet nozzle with vented central electrode
The vented flat jet nozzle serves for the spraying and the charging of the
powder. The powder is charged by the central electrode (
E
). The high
voltage (
H
) created in the gun cascade is guided through the center
electrode.
fig. 4
In order to prevent powder from sintering on the electrode, compressed
air is used during the spray process.
The electrode rinsing air (
S
) can be adjusted on the gun control unit,
depending on the gun type (see corresponding operating manual).
Round jet nozzle with vented deflector and
vented central electrode
The vented deflector is used, to give the powder stream emerging from
the gun, a cloud formation. The powder is charged by the central
electrode (
E
). The high voltage (
H
) created in the gun cascade is guided
through the center electrode.
fig. 5
Since powder can accumulate on the baffle plate, it must be rinsed with
compressed air.
The electrode rinsing air (
S
) can be adjusted on the gun control unit,
depending on the gun type (see corresponding operating manual).
Содержание OptiSelect Pro GM04-CF
Страница 18: ...Rev 00 03 20 18 Product description OptiSelect Pro GM04 CF ...
Страница 26: ...Rev 00 03 20 26 Operation OptiSelect Pro GM04 CF ...
Страница 32: ...Rev 00 03 20 32 Maintenance Repairs OptiSelect Pro GM04 CF Dismantling procedure 1 2 3 ...
Страница 38: ...Rev 00 03 20 38 Disposal OptiSelect Pro GM04 CF ...
Страница 47: ...Rev 00 03 20 OptiSelect Pro GM04 CF Spare parts list 47 Other accessories Gloves anti static 1 pair 800 254 ...
Страница 48: ......
Страница 50: ...Rev 00 ...