Rev. 01 08/16
32
Maintenance / Repairs
OptiSelect GM03
Only cleaning agents with a flash point of a least 5 Kelvin above
the ambient temperature, or cleaning places with technical
ventilation are allowed!
Before cleaning the powder gun, switch off the control unit. The
compressed air used for cleaning must be free of oil and water!
Daily:
1.
Blow off the outside of the gun and wipe, clean etc.
Weekly:
2.
Remove powder hose
3.
Remove the spray nozzle from the gun and clean it with compressed
air
4.
Blow through the gun with compressed air, beginning from the
connection in flow direction
5.
Blow through the gun with compressed air, beginning from the
connection in flow direction
6.
Clean the integrated gun tube with the brush supplied if necessary
7.
Blow through the gun with compressed air again
8.
Clean the powder hose
9.
Reassemble the gun and connect it
Cleaning the spray nozzle
Daily or after every shift
1.
Clean the inside and outside of the spray nozzle with compressed
air.
Never immerse the parts in solvents!
2.
Check the seating of the spray nozzles.
ATTENTION
Threaded sleeve not tightened well
If the spray nozzle is just fitted loosely, there is danger of a flash-
over of the gun high voltage, which can damage the gun!
► Always tighten the threaded sleeve well!
Weekly:
1.
Remove the spray nozzle and clean on the inside with compressed
air. If sinterings should have formed, then they have to be removed!
Monthly
1.
Check spray nozzle for wear
The flat jet nozzle is to be replaced, if:
– the spray pattern is no longer a regular oval
Содержание OptiSelect GM03
Страница 18: ...Rev 01 08 16 18 Product description OptiSelect GM03 ...
Страница 28: ...Rev 01 08 16 28 Operation OptiSelect GM03 ...
Страница 34: ...Rev 01 08 16 34 Maintenance Repairs OptiSelect GM03 ...
Страница 38: ...Rev 01 08 16 38 Disposal OptiSelect GM03 ...
Страница 43: ...Rev 01 08 16 OptiSelect GM03 Spare parts list 43 SuperCorona 1 SuperCorona PC05 1008 165 Wearing part Fig 13 ...
Страница 50: ...Rev 01 ...