Rev. 00 12/21
56
•
Maintenance / Repairs
OptiFeed 4.0 (PP07)
Maintenance
Maintenance based on monitoring of the wear
parts
The powder pump indicates it is time for maintenance by changing the
maintenance indicator from
to
. If the recommended operating
life is exceeded (e.g. pinch valve), the indicator changes to
.
Icon
Status
Condition/Action
OK
–
WARNING
below the warning limit
– Maintenance recommended
ALARM
below the remaining service life
– Carry out maintenance
Maintenance schedule
The maintenance schedule is dependent on the frequency of the pump
use.
The monitoring of the wear parts is linked to the internal pump cycle
counter.
Up to 4 wear parts can be monitored. The service life of the components
depends heavily on the service duration, the powder quality and the
quality of the air supply.
To reduce unnecessary downtime, it is recommended that the pump be
serviced once a year at a minimum, see below.
The specified intervals are based on operation of 8 hours per day.