Rev. 01 08/20
OptiStar All-in-One (CG22-C)
Start-up
35
Determining user address (Node-ID) and Baud
rate
Each Gun control unit, which operates in the CAN network, must have
assigned an individual user address (Node-ID). The Baud rate setting
enables the transmission speed setting. The Baud rate value can be set
by editing the system parameter P05, and the Node ID value can be set
by editing the system parameter P06.
Node ID
– system parameter P06
CAN Node ID 1 -127
P06 value
CAN Node ID
1 -127
1 -127
Baud rate
– system parameter P05
P05 value
Baud rate
0
20 kbit/s
1
50 kbit/s
2
100 kbit/s
3
125 kbit/s
4
250 kbit/s
5
500 kbit/s
6
800 kbit/s
7
1 Mbit/s
Default value of system parameter P05 = 3
The Baud rate is selected with 125 kbits as default. This setting permits a
maximum cable length of approx. 500 m from the first to the last CAN bus
client. If longer cables are used, select a lower Baud rate.
Содержание CG22-C
Страница 6: ......
Страница 28: ...Rev 01 08 20 28 Assembly Connection OptiStar All in One CG22 C ...
Страница 36: ...Rev 01 08 20 36 Start up OptiStar All in One CG22 C ...
Страница 50: ...Rev 01 08 20 50 Operation OptiStar All in One CG22 C ...
Страница 54: ...Rev 01 08 20 54 Maintenance Repairs OptiStar All in One CG22 C ...
Страница 60: ...Rev 01 08 20 60 Disposal OptiStar All in One CG22 C ...
Страница 65: ...Rev 01 08 20 OptiStar All in One CG22 C Spare parts list 65 Powder conveying unit fig 16 ...
Страница 67: ...Rev 01 08 20 OptiStar All in One CG22 C Spare parts list 67 Valve block fig 17 ...
Страница 69: ...Rev 01 08 20 OptiStar All in One CG22 C Spare parts list 69 Connecting material fig 18 ...
Страница 70: ......
Страница 72: ...Rev 01 08 20 72 Index OptiStar All in One CG22 C ...
Страница 73: ......
Страница 74: ...Rev 01 ...