11.6 Bonnet
mounting
on the valve body
1. Move bonnet
A
to the closed position.
2. Open bonnet
A
approx. 20 %.
3. Clean all parts of the remains of product
and contamination. Do not scratch or
damage parts during cleaning!
4. Position bonnet
A
with the mounted
diaphragm
2
on the valve body
1
, take
care to align the diaphragm weir and
valve body weir.
5. Tighten bolts
18
, washers
19
and
nuts
20
by hand (hand tight only).
6. Fully tighten the bolts
18
with nuts
20
diagonally.
7. Ensure that the diaphragm
2
is
compressed evenly (approx. 10 - 15 %,
visible by an even bulge to the outside).
8. Check tightness of completely
assembled valve.
Important:
Service and maintenance:
Diaphragms degrade in the course
of time. After valve disassembly /
assembly check that the bolts
18
and nuts
20
on the body are tight
and retighten as necessary (at the
very latest after the first sterilisation
process).
12 Commissioning
WARNING
Corrosive chemicals!
®
Risk of caustic burns!
G
Check the tightness of the
media connections prior to
commissioning!
G
Use only the appropriate
protective gear when
performing the tightness
check.
CAUTION
Protect against leakage!
G
Provide precautionary measures
against exceeding the maximum
permitted pressures caused by
pressure surges (water hammer).
Prior to cleaning or commissioning the
plant:
G
Check the tightness and the function of
the diaphragm valve (close and reopen
the diaphragm valve).
G
If the plant is new and after repairs rinse
the piping system with a fully opened
diaphragm valve (to remove any harmful
foreign matter).
Cleaning:
The plant operator is responsible for
selecting the cleaning material and
performing the procedure.
Important:
Service and maintenance:
Diaphragms degrade in the course
of time. After valve disassembly /
assembly check that the bolts
18
and nuts
20
on the body are tight
and retighten as necessary (at the
very latest after the first sterilisation
process).
13
Inspection and servicing
WARNING
The equipment is subject to pressure!
®
Risk of severe injury or death!
G
Only work on depressurized plant.
CAUTION
Hot plant components!
®
Risk of burns!
G
Only work on plant that has
cooled down.
45 / 56
673P9
Содержание 673P9 Series
Страница 27: ...27 56 673P9...
Страница 53: ...53 56 673P9...
Страница 54: ...54 56 673P9...