12.4.3 Device access locks
Access to the parameters can be controlled with the
Device access locks
parameter.
Index Sub-
Index
Off-
set
Access
Rights
Length
Index name
Parameter
Type
Values
0x0C
1
0
R/W
1 bit
Device access locks
Parameter (write) ac-
cess
BooleanT
0
1
2
1
R/W
1 bit
Data storage
BooleanT
0
1
3
2
R/W
1 bit
Local parameteriza-
tion
BooleanT
0
1
4
3
R/W
1 bit
Local user interface
BooleanT
0
1
Description of parameter values
Index name
Parameter
Values
Description
Device access locks
Local user interface
0
Enable write access
1
Block write access
Data storage
0
Enable storage of parameter data in the IO-Link master
1
Block storage of parameter data in the IO-Link master
Local parameterization
0
Enable local parameterization
1
Block local parameterization
Local user interface
0
Enable local user interface
1
Block local user interface
12.4.4 Profile Characteristics
The
Profile Characteristics
parameter specifies which DeviceProfileIDs, CommonApplicationProfileIDs and FunctionClassIDs
are supported.
Index Sub-
Index
Off-
set
Access
Rights
Length
Index name
Parameter
Type
Values
0x0D
0
0
RO
8 bytes
Profile
Characteristics
ArrayT
0x8000
0x8002
0x8003
0x8100
Description of parameter values
Index name
Parameter
Values
Description
Profile Characteristics
0x8000
Device identification objects
0x8002
Process data mapping
0x8003
Diagnostics
0x8100
External identification
GEMÜ 639 eSyStep
OPEN / CLOSE (Code AE)
www.gemu-group.com
41 / 67
12 Specific data IO-Link (pin 6)