![GEM 549 eSyDrive Скачать руководство пользователя страница 39](http://html1.mh-extra.com/html/gem/549-esydrive/549-esydrive_operating-instructions-manual_2206253039.webp)
www.gemu-group.com
39 / 47
GEMÜ 549 eSyDrive
3
4. Place the actuator of housing cover
12
in the starting
point for manual override.
3
12
Item
Name
3
Housing cover
12
Housing cover actuator
Starting point for manual override
Groove for actuator
5. Turn housing cover
3
anticlockwise.
ð
The product opens.
6. Turn housing cover
3
clockwise.
ð
The product closes.
7. Pull manual override off the starting point.
8. Ensure correct positioning of the O-ring.
9. Push actuator
12
into the groove provided for this pur-
pose.
10. Turn housing cover
3
anticlockwise until it stops.
ð
The actuator cover is closed.
11. Reconnect the power supply.
15 Operation