www.gemu-group.com
5 / 21
GEMÜ 0324
2 Safety information
The safety information in this document refers only to an indi-
vidual product. Potentially dangerous conditions can arise in
combination with other plant components, which need to be
considered on the basis of a risk analysis. The operator is re-
sponsible for the production of the risk analysis and for com-
pliance with the resulting precautionary measures and re-
gional safety regulations.
The document contains fundamental safety information that
must be observed during commissioning, operation and main-
tenance. Non-compliance with these instructions may cause:
–
Personal hazard due to electrical, mechanical and
chemical effects.
–
Hazard to nearby equipment.
–
Failure of important functions.
–
Hazard to the environment due to the leakage of dan-
gerous materials.
The safety information does not take into account:
–
Unexpected incidents and events, which may occur
during installation, operation and maintenance.
–
Local safety regulations which must be adhered to by
the operator and by any additional installation person-
nel.
Prior to commissioning:
1. Transport and store the product correctly.
2. Do not paint the bolts and plastic parts of the product.
3. Carry out installation and commissioning using trained
personnel.
4. Provide adequate training for installation and operating
personnel.
5. Ensure that the contents of the document have been fully
understood by the responsible personnel.
6. Define the areas of responsibility.
7. Observe the safety data sheets.
8. Observe the safety regulations for the media used.
During operation:
9. Keep this document available at the place of use.
10. Observe the safety information.
11. Operate the product in accordance with this document.
12. Operate the product in accordance with the specifications.
13. Maintain the product correctly.
14. Do not carry out any maintenance work and repairs not de-
scribed in this document without consulting the manufac-
turer first.
In cases of uncertainty:
15. Consult the nearest GEMÜ sales office.
3 Product description
3.1 Construction
2
1
3
4
Item
Name
Materials
1
Plug
PA
2
Coil housing
Standard: PA 6
M12 connection: Duroplast
(Epoxyd NU463)
ATEX version: PPS
3
Valve body
PBT
4
Hollow bolt
Aluminium
Seal materials
FPM
3.2 Description
The GEMÜ 0324 directly controlled 3/2-way pilot solenoid
valve is designed for direct mounting to pneumatically oper-
ated valves. The body is made of plastic. The coil is plastic
encapsulated.
3.3 Functional description
GEMÜ 0324 is a 3/2-way pilot solenoid valve. GEMÜ 0324 is
designed for direct mounting (hollow bolt) to pneumatically
operated valves or other devices.
3.3.1 Safety function
The fail-safe state is defined as the state where the solenoid
valve is de-energized and the valve is returned to the CLOSED
position (de-energized).
3 Product description