GENERAL INSTRUCTIONS: 

 

These instructions should be read carefully and retained after installation for further reference and 
maintenance. 

 

 

SAFETY 

 

  Before installation/maintenance, ensure that the mains supply to the luminaire is switched off and the circuit 

fuses are removed or circuit breakers switched off 

  Installation of this luminaire should only be carried out by a qualified electrician. 

  This product is IP44 rated and suitable for external applications.  

  This product is class l rated and must be earthed 

  Check that the total load on the circuit including when this luminaire is fitted does not exceed the rating of 

the circuit cable, fuse or circuit breaker 

  Please recycle this unit 

  This product is non-dimmable 

 

 

INSTALLATION 

 

  Unfasten the screws at the sides of the mounting bracket and remove the bracket making a note of the 

order of the washers 

  Using the bracket as a template mark the location of the fixing holes. Drill the holes for the fixings ensuring not 

to infringe with any joists, gas or water pipes or electrical cables that may be hidden behind the surface. Subject 

to the surface foundation material please ensure the correct fixings are always used 

  Fix the bracket to the mounting surface 

  Re-fix the fitting to the wall bracket ensuring the washers are in the correct order 

 

 

 

  

SENS 

 

TIME 

 

LUX 

  

 

 

 

 

 

 

 

 

 

   

1-8m 

 

10sec - 8min 

 

 

 

 

 

 

 

 

 

 

120º 

 

 

 
 

SENS 

 

1-8m 

 

 

1-8m 

 

 

 

 

 

 

 

 

 

CLEANING 

 

Clean with a soft dry cloth only, do not use other materials or solutions which may damage the fitting 

  

SENS 

 

TIME 

 

 

 

 

 

  

1-8m 

 

10sec - 8min 

 

 

 

 

 

Adjust the light sensor “LUX” control on the bottom of the 

PIR to required level 

Adjust the “TIME” control on the bottom of the PIR to required 

duration  
(Min - 10 seconds Max – 8 Minutes) 

 

Adjust the sensor head and “SENS” control on the 

bottom of the PIR to achieve desired coverage 

 

(Max sensing angle 180° 1-8m range) 

 

Turn both the controls (“TIME” & “LUX”) mounted on the 

bottom of the PIR anti-clockwise to minimum. (Walk Test 

Mode) 

 

Turn on the power to the unit. The light on the luminaire will 

switch ON and after the pre-set time the light will flash 

quickly 4 times then switch off. This is normal and indicates 

the unit is in Automatic Sensor Mode 

 