GM1118 

Revision Date: 6/22/2012 

 

Specifications 

 

Overview 

The  GBB100  provides  remote  environmental  monitoring  and  alarming  capability  needed  to 
detect climate conditions in data centers.  Additionally, the  GBB100 provides one output relay 
that can be operated remotely or set to automatically open or close based on alarm conditions.  
The GBB100 is equipped with a built-in web server with a 10/100 Mbps connection speed.  Web 
pages are generated by the unit to monitor local environmental conditions.  No software other 
than  a  web  browser  is  required  for  operation  and  several  data  formats  are  available.  The 
GBB100 has a built-in sensor to monitor temperature, humidity and dew point, as well as one 
port for adding remote sensors.  The GBB100 also has four I/O ports for connecting additional 
external  5Vdc  sensors  such  as  Water  and  Door  Sensors.    The  GBB100  can  be  optionally 
configured at the factory to support Power-Over-Ethernet (PoE).  
 

Environmental  

Temperature 

Operating:   10°C (50°F) min 

45°C (104°F) max 

Storage: 

-25°C (-13°F) min  65°C (149°F) max 

 

Humidity 

Operating: 

5% min 

95% max 

(non-condensing) 

Storage: 

5% min 

95% max 

(non-condensing) 

 

Elevation 

Operating: 

0 m (0 ft) min  

2000 m (6561 ft) max 

Storage: 

0 m (0 ft) min  

15240 m (50000 ft) max 

 

Electrical 

6-12 Volts DC, 2 Amps  
 

Output Relay Contact Ratings 

The  output  relay  contacts  are  intended  to  carry  low  voltage  signals  only.    Do  not  exceed  the 
following ratings on the output relay contacts: 
 
DC: 60 V, 30 W 
 
AC: 30 Vrms, 1 A  
 

Warning:     

Consideration  should  be  given  to  lockout-tagout  and  other  procedures 

required  for  servicing  external  devices  controlled  by  the  GBB100  output  relays.  
Appropriate safety precautions must always be taken when operating or maintaining 
equipment connected to the GBB100.  Geist Manufacturing assumes no responsibility 
or  liability  for  any  injury  or  damage  to  any  persons  or  property  resulting  from 
improper operation or maintenance of a device connected to the GBB100. 
 

Содержание GBB100 Series

Страница 1: ...Geist 1821 Yolande Ave Lincoln NE 68521 800 432 3219 402 474 3400 F 402 474 4369 www geistglobal com Instruction Manual Environmental Monitoring Unit with Output Relay GBB100 Series Firmware Version 3...

Страница 2: ...s Page 13 Control Page 14 Configuration Page 15 Unit Configuration 16 Network 16 Time and Date 16 E Mail 17 SNMP 18 User Accounts 19 Admin Information 20 Camera Configuration 20 Relay Control 21 Relay...

Страница 3: ...GM1118 3 Revision Date 6 22 2012 Firmware Updates 29 Resetting the Unit 29 Service and Maintenance 29 More Technical Support 29 Table of Figures 30 Revision History 31...

Страница 4: ...be optionally configured at the factory to support Power Over Ethernet PoE Environmental Temperature Operating 10 C 50 F min 45 C 104 F max Storage 25 C 13 F min 65 C 149 F max Humidity Operating 5 mi...

Страница 5: ...igh Risk Applications Networking Protocols HTTP HTTPS SSL TLS SMTP POP3 ICMP DHCP TCP IP NTP Telnet Syslog Ethernet Link Speed 10 100 Mbps full duplex Data Formats HTML SNMP CSV Plain Text XML EMC Ver...

Страница 6: ...n a cabinet the ambient temperature of the rack should be no greater than 45 C Install the GBB100 such that the amount of airflow required for safe operation of equipment is not compromised Mount the...

Страница 7: ...GM1118 7 Revision Date 6 22 2012 Mounting Figure 1 GBB100 Mounting Options Using the 19 horizontal panel mount brackets attach unit to rack as shown...

Страница 8: ...IP address and will also clear all password settings The Configuration page allows you to assign the network properties or use DHCP to connect to your network Access to the unit requires the IP addre...

Страница 9: ...on the left side of the window and enter these settings on the right side of the window Configure Manually IP Address 192 168 123 1 Subnet Mask 255 255 255 0 Router Leave blank Hit Apply and confirm...

Страница 10: ...data Readings for the internal temperature humidity and dew point sensors along with all I O ports and external sensors will be shown Optional cameras may be added and their live snapshots are shown...

Страница 11: ...ute all sensor data used in the real time display and alarm functions is read at least once every 5 seconds for internal sensors and once every 30 seconds for external sensors Recorded data is availab...

Страница 12: ...s well as change the default temperature unit of measure for sensors The 5Vdc internal analog sensors can also be adjusted to show what every range is necessary for the user There is a linear mapping...

Страница 13: ...ions for each sensor reading Alarm conditions can be established with either high or low trip thresholds The alarms are displayed in different sections based on the sensor the alarm is associated with...

Страница 14: ...has one relay that can be operated remotely or set to automatically open or close based on alarm conditions Friendly names for the relay give the option of changing the state name from Energized De e...

Страница 15: ...evice Sections for Network Time Email SNMP User Accounts Administration Information Cameras and Diagnostics are all housed on this page Each section contains a Save Changes to allow for saving the new...

Страница 16: ...11 Network Configuration Section Time and Date The system clock is set on the Admin section of the Configuration page The unit comes preconfigured with the IP addresses of two NIST time servers and is...

Страница 17: ...are None POP3 POP before SMTP or ESMTP The e mail configuration is set on the Email section of the Configuration page An SMTP server as well as Sender and Destination addresses are required to send e...

Страница 18: ...Network Management Protocol SNMP v1 and v2c In addition alarm traps can be sent to up to two IP addresses The SNMP configuration is entered on the SNMP section of the Configuration page The default re...

Страница 19: ...15 User Accounts Configuration Section User account names may include alphanumeric characters spaces and underscores Passwords may include alphanumeric characters and underscores Note The Administrat...

Страница 20: ...tion Configuration Section Figure 17 Admin Information Display Camera Configuration Enter the domain names IP addresses and models of up to four IP addressable network cameras in the Cameras section o...

Страница 21: ...he desired action in a drop down menu and clicking the execute button The current relay status is displayed in the Manual Override section of the Control page The word forced is displayed next to any...

Страница 22: ...GM1118 22 Revision Date 6 22 2012 Figure 19 Relay Control Options...

Страница 23: ...r below a low trip threshold Clear Occurs when a sensor already in the Tripped or Unplugged state goes back into its normal range Unplugged Occurs when a sensor with an alarm set loses contact with th...

Страница 24: ...ightly between units Allow each unit to operate under normal steady state conditions for several hours before setting alarm thresholds By allowing the sensors to operate for several hours the user can...

Страница 25: ...ure measurements AI1 Scales 0 to 5 Vdc input to 0 99 dry contacts may be used AI2 Scales 0 to 5 Vdc input to 0 99 dry contacts may be used AI3 Scales 0 to 5 Vdc input to 0 99 dry contacts may be used...

Страница 26: ...Digital Sensors RS2 Remote power monitoring and switching RTAFHD3 Compatibility The G RTAFHD3 sensor cannot be utilized in combination with the discontinued G RTAF and G RTAFH sensors or G RTHD sensor...

Страница 27: ...lay page Note The sensor uses Cat 3 wire and RJ12 connectors Wiring must be straight through reverse polarity will temporarily disable all sensors until corrected Note The sensors use a serial communi...

Страница 28: ...ers with multiple units Geist RSC software offers Convenient single window monitoring of multiple units via simple web based interface Streamlined firmware updating Consolidation of alarm settings See...

Страница 29: ...t Figure 25 Web Page Header Firmware Updates Keep your unit updated with the latest firmware releases or sign up for notifications at the following website http www geistglobal com support Resetting t...

Страница 30: ...0 Configuration Page 15 Figure 11 Network Configuration Section 16 Figure 12 Time Configuration Section 17 Figure 13 Email Configuration Section 18 Figure 14 SNMP Configuration Section 18 Figure 15 Us...

Страница 31: ...te 6 22 2012 Revision History Revision Date Notes Approved By 1 0 9 12 2011 Initial Version CG AK 1 1 4 27 2012 Added GTHD and GT3HD CG 1 2 6 22 2012 Changed logo and web address SR 1 3 6 26 2013 Adde...

Отзывы: