GEIGER GFM001 Скачать руководство пользователя страница 3

3

1 Introduction

By deciding to buy the awning control system GFM001 you have made a good choice. The device you

have acquired is a high quality product made by Geiger.
The control system has been designed for the exclusive operation via radio commands.

The system can be operated in the following manner:
• By way of manual operation by means of hand-held- and wall-mounted radio transmitters.
• Through the execution of an automatic program based on the data sensed by special radio sun,

wind and rain sensors.

• In a time-controlled manner via clock-controlled radio transmitter.
The individual radio commands can be allocated to and are operative with regard to the following 

control options:
• Control of individual systems
• Control of a group of systems (arbitrary number of receivers within reach)
• Central control (arbitrary number of receivers within reach)

2 Safety Instructions

• For operation, the awning control system GFM001 requires a supply voltage of 230 VAC, 50 Hz.

Please pay attention to the fact that the control system may only be installed by an expert electrician

(according to VDE 0100).

• The control system is only determined for use within the limits of the specified application described

in section 3 herein. Unauthorised changes of and/or modifications to the control system will result in

the invalidity of all warranty claims.

• Immediately after its unpacking, the control system must be checked for damages. The device must,

in case damages are detected, in no case be put into operation. Once transport damages have

been detected, the supplier of the device has to be notified thereof immediately.

• Whenever it is to be assumed that the device cannot be operated safely, it has to be put out of 

service immediately and be protected against unintended operation. This is the case if the housing

or the mains power or motor supply lines have been damaged or if the device doesn't work 

anymore.

• Both the operator and the firm charged with the installation of the device are, as specified in VDE

0022 (German regulations for electrics), themselves responsible for their complying with the relevant

regulations issued by the local power supply company or the relevant VDE regulations.

• Prior to performing any works on awnings that are driven and controlled by a GFM001 control 

system, always make sure to power off the supply voltage first.

3 Intended Usage

The awning control system GFM001 may only be used to drive 230 VAC, 50 Hz, one-phase motors.
When installing the control system GFM001, care has to be taken to protect the device against the

exposure to water jets (IP54).
When cleaning the awning, never wash down the control directly by means of a water hose or a 

high-pressure cleaning device.

Содержание GFM001

Страница 1: ...EN Awning control system for 230V drives for pre coded systems GFM001 Installation and operating instructions...

Страница 2: ...Extensions and individual settings 6 7 1 Learning of radio commands 6 7 2 Coding set in the condition as delivered 6 7 3 Learning of the coding of a hand held transmitter 6 7 4 Learning of a sensor 7...

Страница 3: ...modifications to the control system will result in the invalidity of all warranty claims Immediately after its unpacking the control system must be checked for damages The device must in case damages...

Страница 4: ...nter key Actuating the counter key stops the approx 0 5 to 1 5 seconds travelling motion immediately Repeated actuation The travelling operation is in travel direction continued without interruption O...

Страница 5: ...ffects that the awning is extended over the term of the remaining runtime Any actuation of the key UP Auf after the attaining of intermediate stop position effects that the awning is retracted over th...

Страница 6: ...hand coding condition as delivered If several control systems are to be installed that shall be operated individually each radio receiver must get its individual coding This can be realised by changi...

Страница 7: ...s purpose Learned intermediate positions can for extending purposes be displaced at any time on the aforementioned timeline To learn an intermediate position proceed as follows 1 Use the related trans...

Страница 8: ...conds another audible signal resounds long tone 4 Immediately let the key EIN ON go again when hearing the long tone 5 All values stored beforehand have been cancelled and the control operates in norm...

Страница 9: ...ndby after power ON 10 min Lock wait time wind 10 min Lock wait time rain 10 min Lock wait time service 5 min Timer function in automatic mode 240 minutes after the system has last command for running...

Страница 10: ...N For technical questions please call our service team at 49 0 7142 938 333 They will be happy to assist you Gerhard Geiger GmbH Co KG Schleifm hle 6 D 74321 Bietigheim Bissingen T 49 0 7142 9380 F 49...