SPECIFICATIONS
ENGINE
Model
CT5-16
CT5-16 Turbo
Type
Perkins 1103C-33
Perkins 1103C-33T
- Number of cylinders
3 in line
3 in line
- Number of cycles
4
4
- Suction
Natural
Turbocharged
- Injection system
Direct
Direct
- Ignition sequence
1, 2, 3
1, 2, 3
- Clearance of rocker valve (cold)
• Inlet
0.78” (20 mm)
0.78” (20 mm)
• Exhaust
1.77” (45 mm)
1.77” (45 mm)
- Capacity
201 cu. in. (3300 cm
3
)
201 cu. in. (3300 cm
3
)
- Bore
4.13” (105 mm)
4.13” (105 mm)
- Stroke
5” (127 mm)
5” (127 mm)
- Compression ratio
19.3:1
18.25:1
- Nominal loaded rating
2200 rpm
2200 rpm
- Low idle
900 ± 10 rpm
900 ± 10 rpm
- High idle
2350 rpm
2350 rpm
- Power ISO/TR 14396
58 hp (43 kW)
75 hp (55 kW)
- Maximum torque
164 ft.-lbs. (222 Nm) at 1400 rpm
215 ft.-lbs. (291 Nm) at 1400 rpm
- Air cleaner
Dry w/safety element
Dry w/safety element
COOLING CIRCUIT
- Type
Water
- Fan
Puller
• Number of blades
10
• Diameter
20” (508 mm)
- Thermostat
• Start opening
174°F to 183°F (79°C to 84°C)
• Full opening
199°F (93°C)
HYDROSTATIC TRANSMISSION
HYDROSTATIC PUMP
- Make and Model
Mannesmann Rexroth A4VG56DA1D7/32R
- Type
Variable volume capacity with automatic power governor
- Transmission control
Electromagnetic 12-V
• Number of forward speeds
1
• Number of reverse speeds
1
- Main pump
• Min. / Max. displacement
0 to 3.42 cu. in./rev. (0 to 56 cm
3
/rev.)
• Max. flow rate
33 gpm (125 L/min)
• Working pressure
2610 psi (180 bar)
- Charge pump
• Boost pressure, Max. RPM
363 psi (25 bar) (transmission in neutral)