background image

2

1

Intended Use

The

ABAC

  Motor  Blower  SG 90  E  (electronic)  –  named  in  this  manual  also  as  Motor

Blower  or  simply  Blower  –  is  intended  to  be  used  in  connection  with  the

ABAC

  Low

Pressure  Spray  Guns  PN 2  or  PN 5  to  spray  and  apply  paints  and  lacquers.  For

spraying you may use materials approved by paint manufacturers for High Volume Low

Pressure (HVLP) air-spraying technique application. These are for instance:

·

  Patina  paints,  two-component-paints,  synthetic  resin  alkyd  paints,  acrylic  and

dispersion paints, colour effect paints, insulation / inflammation protection, sprayable

wax materials.

Any use of the Motor Blower different from described in this manual is prohibited.

Identification  number  of  SG 2500  Motor  Blower  is  BJ 370 000 0021  (100 V),

BJ 370 000 0041 (115 V), BJ 370 000 0002 (230 V).

Always  observe  and  comply  with all  processing instructions  and  safety  notes  provided

by material manufacturers as well the prescriptions of this operating manual.

In any case, only paints and solvents with a flash point above 21

°

C = 70

°

F may be used

for spraying!

The

ABAC

Motor  Blower  SG 90  E  is  designed  to  be  operated  with  PN 2  /  PN 2A  and

PN 5

ABAC

 Spray Guns.

It is prohibited to use the

ABAC

Motor Blower SG 90 E together with

spray  guns  with  intermittent  air  supply  (for  example,  with

ABAC

PN 1 / PN 1A Spray Guns)! In case of their co-use, when air supply

will  be  stopped  for  spraying  (by  trigger  release),  motor  overheating

and  unit  breakdown  may  occur  due  to  air  backflow  and

accumulation.

Ambient  temperature  range  for  equipment  operation  is  from  0

°

С

  to  +45

°

С

,  relative

humidity must not exceed 80%. Conditions of transportation and storage see Section 5.

Содержание ABAC SG 90 E

Страница 1: ...Geheit GmbH Benzstra e 2 D 72636 Frickenhausen Germany Phone 49 0 7022 78969021 Fax 49 0 7022 78969029 www shop geheit de Motor Blower SG 90 E Operating Manual...

Страница 2: ...as aplicadas Normas harmonizadas aplicadas Norme armonizate aplicate Zastosowane normy zharmonizowane Pielietotie harmoniz tie standarti Kohaldatud harmoniseeritud normid Taikyti darnieji standartai P...

Страница 3: ...are Maintenance and Repair 10 8 1 Replacing Intake Filter 11 9 Faults Possible Causes and Remedies 12 10 Operating Instructions 13 11 Spare Parts 13 2019 by Geheit GmbH Printed in Germany All rights r...

Страница 4: ...s BJ 370 000 0021 100 V BJ 370 000 0041 115 V BJ 370 000 0002 230 V Always observe and comply with all processing instructions and safety notes provided by material manufacturers as well the prescript...

Страница 5: ...e Motor Blower is self cooled which means that working air sucked from the atmosphere is also used to cool the motor If any blocking at discharge appears and exists for some time the unit will be over...

Страница 6: ...V 1 N 50 60 Hz AC 115 V 1 N 50 60 Hz AC 230 V 1 N 50 60 Hz o Insulation Protection Class II o Power 1130 W o Power consumption approx 10 2 A 100 V approx 10 2 A 115 V approx 5 6 A 230 V o Speed 25 00...

Страница 7: ...y for use with our own PN 2 or PN 5 ABAC low pressure spray guns which operate in the low pressure range up to 0 45 bar You must also follow the instructions given in the relevant operating manuals fo...

Страница 8: ...tin When working in confined spaces these must be properly ventilated using effective technical ventilation systems The sprayed paint emerges from the nozzle at high pressure Never direct the spray je...

Страница 9: ...to spray in the direction of your Motor Blower Dispose of your cleaning and spraying material wastes according to the instructions given by the relevant lacquer paint and solvent manufacturers The ai...

Страница 10: ...is from 0 to 45 relative humidity must not exceed 80 Attention Use for transport only the handle of the Motor Blower Never attempt to move the Blower by pulling on its air hose or electric cable Use o...

Страница 11: ...voltage indicated on the rating plate or in this Operating Manual Connect the air hose to the Blower by turning the air hose connector clockwise in the blower opening fig 4 6 2 Switching on and Adjust...

Страница 12: ...s or borders of the object to be sprayed are properly masked 7 Switching off the Motor Blower After you have finished spraying turn off the Blower by pressing the push button with your thumb Only then...

Страница 13: ...lter cap Always replace the intake filter when it is dirty Do not attempt to clean it The intake filter should always be checked before spraying and replaced when dirty as shown in figure 7 This ensur...

Страница 14: ...Motor Blower delivers too much or too little air Rotary knob incorrectly set Reset rotary knob such that required air quantity is delivered Motor Blower will not run No mains voltage Check mains conne...

Страница 15: ...all employees 11 Spare Parts For safety reasons you should only use ABAC original accessories and ABAC original spare parts Spare parts are available from your ABAC specialist dealer or directly from...