4.2. Replacing F2/1, F5, F9 with KFM LD
The attachment and mounting dimensions of the listed drives are identical. The assignments on the connection
plugs are identical. They can continue to be used on the KFM LD drive unchanged. Pin assignments with the
corresponding signals can be found in Chap. 4.3 on page 25.
Note !
With the KFM LD drive, it is possible that the connection lines may need to be lengthened on account of the prior separate ar-
rangement of the controller.
During installation, the drive must be de-energised!
Disassembly:
Disassembly of the F2/1, F9 and F9 drive is to be performed in the reverse order of that de-
scribed in Chap. 4.1 on page 23. To remove the cable from the controller housing, the connectors are to be
removed. Note the pin assignments and wire colours. After inserting the connection wires through the cable
bushings of the KFM LD drive, connect the connector according to your notes or connection diagram in Chap.
the KFM LD drive, the connecting lines from the controller to the drive are no longer used. Furthermore, the
previous controller housing must be removed.
Installation:
The description in Chap. 4.1 on page 23 applies for the installation of the new KFM LD drive.
4.3. Connecting
4.3.1. X2 for trigger signals with pin assignments
Trigger signals
1
2
3
4
5
6
0V signals - active
+24V
0V
TU
TO
Default TUL
Approval inspection
24V signals - active
0V
+24V
TU
TO
Default TUL
Approval inspection
Tab. 19 Connect door drive via conventional 24V logic level Input
Acknowledge signals
1
2
3
4
24V/0V signals
Default TSU
Default TSO
Default > 150
N closing force
Default LT light
grid
Tab. 20 Connect door drive via conventional 24V logic level Output
0 Volt trigger and acknowledge signals active: left-hand graphic.
0 Volt trigger signals active. 24 Volt acknowledge signals active: right-hand graphic
Fig. 14
24 Volt control and acknowledge signals active:
Important
KFM LD • Instruction manual
25