H1
green
H2
yellow
H3
green
H4
red
Meaning
*
-*
Press the button for 5 seconds, then release (start of automatic commissioning)
*
-*
Learn the door width
-
*
-*
Learn the operating force
*
-*
Learn the door mass
0
0
0
-*
Conclusion: Parameters were checked and saved, 5 s to automatic RESET.
0
0
0
0*
RESET
-
0
0
-*
State after successful commissioning
Tab. 27 Process for automatic commissioning
H1
green
H2
yellow
H3
green
H4
red
Meaning
0
-
-
-*
No commissioning whatsoever has been carried out
-
-
0
-*
Manual or automatic commissioning has been carried out, but HEX S2 is not located in the correspond-
ing position.
-
0
0
-*
HEX S2 is located in the position of the last automatic commissioning, values not modified.
-
0
-*
HEX S2 is located in the position of the last modified automatic commissioning
Tab. 28 Normal door operation
Explanation:
*If LED H4 lights up,
this corresponds to a fault indicator! If the learning procedure aborts during automatic
commissioning or while learning aipm, LED H4 flashes continuously.
If LED H4
blinks
continuously, this indicates a switch-off error, for example overtemperature or undervoltage
with enabling of the output stages. (*flashing = very rapid blinking).
5.5.1. Error messages during automatic commissioning
LED H4 continuously flashes in red
Error
no.:
H1
green
H2
yellow
H3
green
Description of reason for abort
Possible cause
71
-
-
-
Timeout (10 sec) when learning the cam path
>Belt tension too weak (belt slippage)
72
0
-
-
Timeout (10 sec) when relaxing the belt after
learning the cam path
> Same as with 71 (belt slippage)
73
-
-
0
Learned cam path > 80 mm
> Door for automatic teach-in not in starting
position
> Belt tension too weak (belt slippage)
> Cam path really too large
74
0
-
0
Timeout (25 sec) when learning the door width
> Same as 71 (belt slippage)
75
-
0
-
Timeout (10 sec) when learning the door width
(door in position "open")
> Same as 71 (belt slippage)
76
0
0
-
Learned door width (fwn) not in permitted range
(≥ 30 cm ≤ fwn ≤ 51200 impulses or ≤ 100
motor revolutions)
> Belt tension too weak (belt slippage)
> aipm incorrectly learned / set
> Door width really too small / too large
77
-
0
0
Timeout (25 sec) when closing the door after
learning the door width
> Same as 71 (belt slippage)
78
0
0
0
Timeout (25 sec) when relaxing the belt after
closing the door (door in "CLOSED" position)
>Same as 71 (belt slippage)
79
-
-
Offset values for encoder system not between 67
and 107
> Same as 71 (belt slippage)
80
0
-
Door width not correctly learned. Difference be-
tween opening / closing is less than -100 or greater
than 300 impulses
> Belt tension too weak (belt slippage)
> On closing, cam has blocked
81
-
0
Timeout (10 sec) when learning the cam path,
whereby the moving direction was altered in the
meantime
> Belt tension too weak (belt slippage)
82
0
0
The required torque is too high when learning
the force to open the door. (5 cm before position
"DoorCLOSED")
> Door blocked (landing door lock?)
> Wrong reduction ratio
34
KFM LD • Instruction manual
Содержание KFM LD
Страница 1: ... Instruction manual Door Drive KFM LD ...