background image

3

80543B_MHW_GF_VEDO-TL_0109_ENG

Preliminary warnings

Read the following preliminary warnings before
installing and using the GF_VEDO TL operator
terminals. Doing so makes start-up quicker
and lets you avoid some problems that might
be mistaken for malfunctions or limitations of
the terminal.

• Immediately after unpacking the product, make a note
of the order code and the other identification data given
on the label affixed to the outside of the  container and
copy them to the table below.
These details must always be kept close at hand and
referred to the personnel involved in the event of help
from Gefran Customer Service Assistance.

• Check that the terminal is in perfect condition and was
not damaged during shipment. Make sure that the pac-
kage also contains the fastening accessories and the
installation CD-ROM. Any inconsistencies, omissions or
evident signs of damage should be reported immediately
to your Gefran sales agent.
• Check that the order code corresponds with the confi-
guration requested for the application the terminal is
needed for, referring to Section: “Technical - Commercial
Information”.

Example: GF_VEDO - 104CT - VW - C1 - S1 - G
• Model: GF_VEDO 104CT
• Operating system: Vx Works
• Expansion 1: CANopen
• Expansion 2: RS232 + AUC
• Lexan: Gefran

Consult the section “Installation and Connection” before
installing the terminal on the machine control panel or
host system Consult the section “Sales Information” for
the order code. Users and/or system integrators who
want more detailed information on serial communication
between standard PCs and/or Gefran Industrial PCs
and Gefran Programmable Instruments may access the
various Technical Reference Documents in PDF format
available on Gefran’s website: www.gefran.com.
In the event of presumed instrument malfunction, before
contacting Gefran Technical Service Assistance, refer to
the Troubleshooting Guide given in Section "Maintenan-
ce", and if necessary refer to the F.A.Q. Section (Fre-
quently Asked Questions) on the Gefran Web Site
www.gefran.com

SN:

......................... (Serial no.)

CODE:

......................... (Finished product code)

TYPE:

......................... (Order Code)

SUPPLY: ......................... (Type of electrical power supply)

VERS:

......................... (Software version)

1 • PRELIMINARY INSTRUCTIONS

This section contains information and warnings of a general nature which should be read before procee-

ding with controller installation, configuration and use.

General description

The GF_VEDO TL operator terminal line is a compact

and low-cost solution for machine control.

A single product integrates machine cycle control

[SoftPLC] and graphic page display [SCADA], allowing

quick and low-cost creation of many automation solu-

tions.

The GF_VEDO TL terminals create the machine/opera-

tor interface by means of LCD monitor, touch-screen,

and a wide variety of peripheral I/Os.

GF_VEDO TL terminals are applied mainly to machine

control for packaging, metals, wood and plastic applica-

tions. This Installation Guide describes the main charac-

teristics of the operator panels and refers to the follo-

wing models:

GF_VEDO TL 65CT

Operator interface with 6.5” LCD TFT color display

GF_VEDO TL 65CK

Operator interface with 6.5” LCD TFT color display and integrated
47-key keyboard

GF_VEDO TL 104CT

Operator interface with 10.4” LCD TFT color display

GF_VEDO TL 104CK

Operator interface with 10.4” LCD TFT color display and integrated
54-key keyboard

Содержание GF_VEDO TL 104CK

Страница 1: ...stems 12 3 4 Bios 12 3 5 Integrated keyboard in CK versions 12 3 6 GF_VEDO TL user connections 13 3 6 1 Power supply port 14 3 6 2 Auto start port optional 15 3 6 3 Ethernet ports 15 3 6 4 RS 232 port...

Страница 2: ...rporation PREFACE This manual provides a detailed description of the main technical data of the various versions of Gefran s GF_VEDO TL product The following information is indispensable for the cor r...

Страница 3: ...Cs and or Gefran Industrial PCs and Gefran Programmable Instruments may access the various Technical Reference Documents in PDF format available on Gefran s website www gefran com In the event of pres...

Страница 4: ...losive environments it may be connected to equipment operating in such atmospheres only by means of appropriate and adequate types of interface conforming to the applicable safety standards Notes Conc...

Страница 5: ...utput ones Inputs and outputs connection To connect the analogue inputs strain gauge linear TC RTD the following is necessary physically separate the input cables from those of the power supply the ou...

Страница 6: ...d in mm with tolerance of 0 5 GF_VEDO TL 65CT dimensions 179 5 187 127 133 115 67 177 5 166 125 74 5 Fig 1 Dimensions and cut out GF_VEDO TL 65CT Fig 2 Dimensions and cut out GF_VEDO TL 65CK 180 222 1...

Страница 7: ...7 80543B_MHW_GF_VEDO TL_0109_ENG GF_VEDO TL 104CT dimensions Fig 3 Dimensions and cut out GF_VEDO TL 104CT 258 184 166 266 115 182 5 61 256 68 5 192 5...

Страница 8: ...8 80543B_MHW_GF_VEDO TL_0109_ENG Fig 4 Dimensions and cut out GF_VEDO TL 104CK GF_VEDO TL 104CK dimensions 258 281 68 266 289 115 8 120 5 279 44 5 5 256 5 166 45 45...

Страница 9: ...L GF_VEDO TL panels are designed for front panel installation After making the opening shown on the template drawing fasten the GF_VEDO TL with the blocks required and supplied with the product Fig 5...

Страница 10: ...10 80543B_MHW_GF_VEDO TL_0109_ENG Fig 7 Panel mounting GF_VEDO TL 104CT Fig 8 Panel mounting GF_VEDO TL 104CK...

Страница 11: ...ghten each fastening screw or nut until the corner of the frame touches the panel the panel hole must have the dimensions specified in this manual The GF_VEDO TL terminals also have an O Ring inserted...

Страница 12: ...k Film Transistor color displays measuring 6 5 or 10 4 as shown in Table 14 3 2 CPUs and Memories GF_VEDO TL terminals are equipped with GEODE SC1200 processors Mass memory devices such as DOM Disk On...

Страница 13: ...net 10 100 Base T KEY LED Fieldbuses keyboard RS485 Optoisolated RS 485 serial AUTO START Auto power on 24VDC Power supply AUX Auxiliary options PC KEY AUX Auxiliary PS 2 keyboard Table 4 GF_VEDO TL c...

Страница 14: ...system must be grounded Ground the devices in a manner conforming to applicable standards and regulations Fig 13 GF_VEDO TL power supply auto power on connector Pin Description 1 Power supply common...

Страница 15: ...eive data 2 TX_D Tranceive data 3 RX_D Receive data 4 N C Not connected 5 N C Not connected 6 RX_D Receive data 7 N C Not connected 8 N C Not connected LED green left Link LED yellow right Data Table...

Страница 16: ...t Ready 7 O RTS Request To Send 8 I CTS Clear To Send 9 I RI Ring Indicator Table 7 Signal assignment for GF_VEDO TL RS 232 port 3 6 5 RS 485 port GF_VEDO TL uses the RS 485 port to dialog according t...

Страница 17: ...1 2 O CAN_L CAN Low 3 O CAN_GND CAN Ground 4 5 EARTH Ground 6 7 O CAN_H CAN High 8 9 Table 9 Signal assignment for GF_VEDO TL CAN port 3 6 7 USB ports GF_VEDO TL uses USB ports to dialog via USB Unive...

Страница 18: ...KEY LED port connector Pin Name Description 1 KEYCLK Keyboard clock 2 KEYOUT Keyboard output 3 KEYIN Keyboard input 4 IRST Reset GT Tast 5 POWER 5V power supply 6 GND 0V power supply 7 GND 0V power s...

Страница 19: ...EDO TL 3 7 1 DOM mass memory GF_VEDO TL has a mass memory containing the operating system the application and user information The GF_VEDO board has a 44 pin 2 mm pitch connector that can be used to c...

Страница 20: ...static RAM memory when the GF_VEDO TL is off for a maximum period of 3 years When necessary replace the battery as follows get a replacement battery button type 24 mm diameter 3V lithium CR2430 switc...

Страница 21: ...21 80543B_MHW_GF_VEDO TL_0109_ENG Modbus TCP IP 4 CONNECTION EXAMPLES HMI GF_VEDO TL 104CT I O Gilogik Modbus RTU PID GFX4 Company Ethernet HMI GF_VEDO TL 104CT DRIVE XVy I O Gilogik CANopen...

Страница 22: ...5kBaud D Sub 9 PM USB 2 x USB 1 1 Host 500mA connector 4 pin type A KEY LED RJ45 connector RJ45 connector without LED without LED Keyboard Mouse PS2 Connector 6 pin miniDIN green Mouse violet Keyboard...

Страница 23: ...h time the Gefran Customer Care Service is contacted for assistance with any problems Order code 1 2 Kindly contact GEFRAN for information on available codes MODEL 65CT GF_VEDO GF_VEDO TL 65CT 65CK GF...

Отзывы: