background image

18

81086_G-Vision 67_12-2021_ENG

- The equipment shall only be used in an area of not more than 

pollution degree 2, as defined in IEC/EN 60664-1.

- The equipment shall be installed in an enclosure that provides 

a degree of protection not less than IP 54 in accordance with 

IEC/EN 60079-15.

- Transient protection shall be provided that is set at a level 

not exceeding 140 % of the peak rated voltage value at the 

supply terminals to the equipment.

- Install the HMI device according to the accompanying 

installation instructions.

- Ground the HMI device according to the accompanying 

installation instructions.

-  Only  qualified  personnel  may  install  the  HMI  device  or 

repair it. 

- Care shall be taken not to allow layers of dust to form on the 

graphic panel in a way that might cause the accumulation of 

static charges. Keep the faceplate of the HMI device clean: 

the equipment must be cleaned only with a soft cloth and 

neutral soap product. Do not use solvents.

- This device should not be used for purposes and methods 

other than indicated in this document and    

in  the 

documentation accompanying the product.

G-Vision devices products delivery configuration is based on a 

loader. Use the services of the loader to install applications on 

the device such as GF Designer HD or GF Project VX runtime. 

GF Designer HD or GF Project VX  are required, they are 

Gefran IDE software tools that must be properly installed on 

a computer running Microsoft Windows.

If you are planning to use your G-Vision with Gf Project VX 

you must first initialize it using the 

“System Settings menu” 

(see next chapter).

In “Application” menu select “App Management” and then 

“install/update”.

At this point you need the files 

“ata0a.zip” and “ata0a.zip.

md5sum” contained in the GF project VX installation folder 

(C:\Gefran  Automation  Builder\GF_ProjectVX-4.x.x-64bit\

diskimages\install_zip\G-Vision\).

If you are accessing to system settings through a browser in 

your PC simply point at the files in the indicated folder. 

If you are operating directly on the panel touch screen insert 

a USB key were you previously copied the files.

After proceeding with the installation procedure the panel 

needs to reboot and will be ready to download the application 

directly from GF Project VX.

If you are planning to use your G-Vision with GF Designer HD 

there are two options to transfer a GF Designer HD runtime 

and application project to the device:

Ethernet

Connect the HMI device to the computer with 

an Ethernet network. In GF Designer HD select 

the command Run/Download to target. You may 

have to ensure that the proper firewall policy has 

been configured in the computer to allow GF 

Designer HD to access the network.

USB

Create an Update Package using GF Designer 

HD and copy it to a USB Flash drive. Insert 

the USB key in the G-Vision and proceed in 

“Application” menu as indicated for GF Project 

VX.

9. GETTING STARTED

8. SPECIAL INSTRUCTION FOR USE

Содержание G-Vision 67-070

Страница 1: ...ree download from the GEFRAN website www gefran com Installers and or maintenance personnel are required to read this manual and to precisely follow the instructions contained in it and in its attachm...

Страница 2: ...notice The information contained in this document is provided for informational purposes only While efforts were made to verify the accuracy of the information contained in this documentation it is pr...

Страница 3: ...NS 7 4 TECHNICAL DATA 9 4 1 Dimensions 10 4 2 Installation Environment and procedure 13 4 3 Safety instruction 13 5 CONNECTIONS 14 5 1 Ethernet Port 14 6 POWER SUPPLY GROUNDING AND SHIELDING 15 7 BATT...

Страница 4: ...three levels of severity DANGER indicates a failure to observe safety rules and such failure may cause death or serious injuries SAFETY GUIDE ATTENTION indicates a failure to observe safety rules and...

Страница 5: ...lerator Runtime with OPC UA Server and Client Built in sensors temperature and acceleration Wi Fi Connection and NFC Device Full IP protection ideal for mounting arm installation 2 STANDARDS AND APPRO...

Страница 6: ...32495AA manufacturer address Gefran Soluzioni Srl Via Sebina 74 25050 Provaglio d Iseo BS Product Identification The product may be identified by the indications in the back cover You will have to kno...

Страница 7: ...0068 2 6 Shock 50 g 11 ms 3 pulses per axis EN 60068 2 27 Protection class IP67 requires appropriate connectorisand cables EN 60529 ELECTROMAGNETIC COMPATIBILITY EMC Radiated disturbance test Class A...

Страница 8: ...tion Surface resistance Chemical resistance of the front glass for an exposure time of 24 hours without visible changes Betadine 10 Povidone Solution Cola Electrode Gel Paste Hydrogen Peroxide 3 Solut...

Страница 9: ...nsors Temperature 3 Axis Accelerometer Buzzer Yes NFC ISO IEC 14443A Wi Fi IEEE 802 11a b g Ratings Power supply IEEE 802 3bt 4PPoE Power Consumption 10W 14W 21W 32W Battery Rechargeable Lithium batte...

Страница 10: ...81086_G Vision 67_12 2021_ENG 4 1 Dimensions MODEL A B C D G Vision 67 070 131 6mm 5 18 195 2mm 7 68 16 5mm 0 64 17mm 0 66 MODEL A B C D G Vision 67 101 183 1mm 7 20 264 5mm 10 41 16 5mm 0 64 17mm 0...

Страница 11: ...11 81086_G Vision 67_12 2021_ENG MODEL A B C D G Vision 67 156 248mm 9 76 398 6mm 15 69 26 5mm 1 04 17mm 0 66 MODEL A B C D G Vision 67 215 325 6mm 12 81 534 1mm 21 02 26 5mm 1 04 17mm 0 66 Rear view...

Страница 12: ...12 81086_G Vision 67_12 2021_ENG...

Страница 13: ...t use tools of any kind screwdrivers etc to operate the touch screen of the panel The IP67 is guaranteed only if max deviation from the plane surface to the cut out O0 5mm thickness of the case where...

Страница 14: ...rt The Ethernet port have two status indicators Please see description in figure Reserved Pin Description 1 TX 2 TX 3 RX 4 n c 5 n c 6 RX 7 n c 8 n c Red OFF Valid link has NOT been detected ON Valid...

Страница 15: ...the effects of noise due to electromagnetic interference on the control system The earth connection can also be made using the screws located near the connector A label helps identify the ground conn...

Страница 16: ...ble The following information is maintained by the battery hardware real time clock date and time Charge At first installation must be charged for 48 hours When the battery is fully charged it ensures...

Страница 17: ...ig 7 3 G Vision 67 156 IP67 Fig 7 4 G Vision 67 215 IP67 ATTENTION Dispose of batteries according to local regulations ATTENTION This device cannot be disposed of as a domestic waste but according to...

Страница 18: ...IDE software tools that must be properly installed on a computer running Microsoft Windows If you are planning to use your G Vision with Gf Project VX you must first initialize it using the System Set...

Страница 19: ...the context menu click and hold any unused area of the touchscreen for a few seconds Default hold time is 2 seconds Activation of Systems Settings in System Mode Normal operation If GF Designer HD ru...

Страница 20: ...date of Main OS is available only in System Mode the update of Config OS is only in User Mode Display Adjust display brightness configure automatic backlight turnoff and select HMI orientation 90 180...

Страница 21: ...21 81086_G Vision 67_12 2021_ENG 11 UNPACKING AND PACKING INSTRUCTIONS Fig 11 1 Fig 11 2 To repack the unit please follow the instructions backwards...

Страница 22: ...22 81086_G Vision 67_12 2021_ENG NOTE NOTE...

Страница 23: ...23 81086_G Vision 67_12 2021_ENG NOTE...

Страница 24: ...Gefran Soluzioni srl Via Sebina 74 25050 Provaglio d Iseo BS Italy Tel 39 0309888 1 Fax 39 0309839063 info gefran com http www gefran com www gefran com en gefran soluzioni...

Отзывы: