RS-232 SERIAL CONTROL
#LOCKEDID Function
The #LOCKEDID function secures the Local EDID and disables the automatic
loading of the downstream EDID after the Matrix is powered on.
Syntax:
#LOCKEDID param1
Parameters:
param1
Input
[0 - 1]
Value
Meaning
0
Disable
1
Enable
#LOEDIDTOLO Function
The #LOEDIDTOLO function loads an external EDID via RS-232 to any Local
EDID input bank.
Syntax:
#LOEDIDTOLO param1 param2 param3
Parameters:
param1
Input
[1 - 10]
param2
EDID size
[1 - 2]
Value
Meaning
1
128 byte EDID
2
256 byte EDID
param3
eco
[0 - 1]
Notes
:
Set
param1
to a value of 0 in order to specify all inputs. When using HyperTermi
-
nal,
param3
must be set to 1.